• 280W Hot Sale Swimming Pool Centrifugal Water Pump System 1
280W Hot Sale Swimming Pool Centrifugal Water Pump

280W Hot Sale Swimming Pool Centrifugal Water Pump

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

best swimming pool pump
Appy for the circulation and filtration of the small swimming pool
Big output,high lift.

Swimming Pool Pump

 

Application:

Apply for the circulation and filtration of the small swimming pools (family use), whirl pools and sauna pools. 

Apply for the circulation and filtration of seafood in hotels, restaurants and farms 

 

Key feature: 

  1. 1. Pump body, pump cover and impeller are made of high quality plastic

  2. 2. Self priming pump for trouble-free operation and air handling 

  3. 3. Stainless steel pump shaft suited for salt water pools 

  4. 4. Reinforced pump base keeps the motor high and dry for corrosion protection 

  5. 5. Big output, high lift. Low noise 

  6. 6. Good mechanical seal and durable

  7. 7. With over load protection to ensure long lasting working 

  8. 8. With simple suction and discharge pipes

  9. 9. Integrated filter 

 

Assessories:

  1. 1. Owner’s manual

  2. 2. Hose adapter

3.  Warranty Card

Performance curves:

 

Operating Limits: 

Fluid temperature up to +35

 

Model

HLS-280

HLS-370

HLS-550

HLS-750

HLX-150

HLX-200

HLX-300

Power

W

280

370

550

750

1100

1500

2200

HP

0.37 

0.49 

0.73 

1.00 

1.47 

2.00 

2.93 

Flow

l/h

7800

10800

12900

14400

29000

32000

36000

Head

m

7

9

10

11

16

17

18

Bar

0.7

0.9

1

1.1

1.6

1.7

1.8

Inlet

inch

 1/1/4"

2"

2"

2"

2/1/2"

2/1/2"

2/1/2"

Outlet

inch

 1/1/4"

2"

2"

2"

2/1/2"

2/1/2"

2/1/2"

Solid

mm

N/A

2*2.5

2*2.5

2*2.5

N/A

N/A

N/A

IP 

Grade

IPX4

IPX4

IPX4

IPX4

IPX4

IPX4

IPX4

Weight

Kg

23

18.5

20

21

18.5

19.4

22.4

Impeller

pc

1

1

1

1

1

1

1

Cable

m

1.5

1.5

1.5

1.5

1.5

1.5

1.5

FOB(Shanghai)

Price(USD/pcs)

??

Packing size(m)

q'ty/ctn

4

2

2

2

1

1

1

Length

0.385

0.55

0.55

0.55

0.53

0.53

0.53

Width

0.385

0.42

0.42

0.42

0.31

0.31

0.31

Height

0.45 

0.32 

0.32 

0.32 

0.40 

0.40 

0.40 

m3

0.07 

0.07 

0.07 

0.07 

0.06 

0.06 

0.06 

MOQ

pcs

20

10

10

10

5

5

5

20

pcs

1800

742

742

742

370

370

370

40

pcs

3600

1568

1568

1568

770

770

770

40H

pcs

3600

1792

1792

1792

924

924

924

Q:Double floor sewage pump circuit diagram of a small problem
Q 2, SA and SS are select switches, and different positions indicate the same difference between the two nodes. SA hits the left position 13, 14 to connect, hits to the right position 21, 22 to connect. SS hit the middle position, 5 and 6 turn on, 7 and 8 turn on; hit the right position; 1 and 2 turn on; 11 and 12 turn on; hit the left seat; 9 and 10 turn on; 3, 4 turn on.
Q:What is the Rhodes pump?
Best answerRoots vacuum pump (referred to as: Roots pump) refers to the pump is equipped with two opposite direction of synchronous rotation of the leaf rotor, rotor, rotor and pump housing between the walls of a small gap and no contact with a variable capacity vacuum pump.Roots vacuum pumps have been tested for long time in the fields of petroleum, chemical, plastic, pesticide, steam turbine rotor dynamic balance and aerospace simulation, so it should be popularized and applied in china. It is also widely used in petroleum, chemical, metallurgical, textile and other industries. Vacuum pump fittings are used for noise control of vacuum pumps, vacuum pump silencers.
Q:What does "efficiency" mean in a water pump catalog?
General pump efficiency is 60% ~ 85%. high efficiency of the pump, indicating the same work, the pump consumes the lowest energy, and vice versa
Q:What are the uses and precautions of magnetic pumps?
Installation and use of magnetic pumps:1, the magnetic pump should be installed horizontally, should not be erected, the plastic pump body can not bear the weight of the pipeline, for the special requirements of vertical installation occasions, the motor must be facing up;
Q:No negative pressure water supply equipment, both the main pump and auxiliary pump, power is not the same, how to choose the control cabinet?
1) microcomputer frequency conversion control cabinet2) water pump unit3) current stabilizing compensator4) vacuum suppressor5) all kinds of pipe fittings, valves and so on
Q:How to select metering pump head?
The main index affecting the selection of the pump head is the composition of the medium to be transported and added, as well as the pressure and the temperature of the external environment
Q:How accurate is the metering pump?
Three automatic compensation valve device widely used in diaphragm metering pump, especially with suction height requirements, can only be used by three separate Fujian (safety valve, discharge valve and oil supply valve) compensation device.
Q:Fire control center manually start the fire pump directly, multi line control, called straight up line NHKVV-7*1.5, my understanding is: straight line from fire control center
The vertical line NHKVV-7*1.5 is the remote starting line of fire controller to fire pump room.
Q:Is the centrifugal pump large or small?
NPSH is also called cavitation, cavitation is too big to be.3, pump the liquid when working in the impeller inlet will produce vapor due to a certain vacuum pressure, vaporization of the air bubbles in the liquid particle movement under the impact of erosion on the impeller, the metal surface, thus undermining the impeller and other metal, then vacuum pressure is called vaporization pressure, NPSH is excess vaporization pressure of surplus the energy position of the unit weight of the liquid in the pump suction port of. The unit with annotation, (NPSH) r with. The absorption process is necessary NPSH H: pump suction fluid allows the vacuum pump installation height is allowed, in meters.
Q:How to distinguish the flow and displacement in the hydraulic pump? What's the difference between the two?
For example, once you sprinkle water from the tank to the ground, one shot of water is 1000 milliliters, which is equivalent to displacement, once (pump turn) 1000 ml.,

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords