280W Hot Sale Swimming Pool Centrifugal Water Pump

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specifications

best swimming pool pump
Appy for the circulation and filtration of the small swimming pool
Big output,high lift.

Swimming Pool Pump

 

Application:

Apply for the circulation and filtration of the small swimming pools (family use), whirl pools and sauna pools. 

Apply for the circulation and filtration of seafood in hotels, restaurants and farms 

 

Key feature: 

  1. 1. Pump body, pump cover and impeller are made of high quality plastic

  2. 2. Self priming pump for trouble-free operation and air handling 

  3. 3. Stainless steel pump shaft suited for salt water pools 

  4. 4. Reinforced pump base keeps the motor high and dry for corrosion protection 

  5. 5. Big output, high lift. Low noise 

  6. 6. Good mechanical seal and durable

  7. 7. With over load protection to ensure long lasting working 

  8. 8. With simple suction and discharge pipes

  9. 9. Integrated filter 

 

Assessories:

  1. 1. Owner’s manual

  2. 2. Hose adapter

3.  Warranty Card

Performance curves:

 

Operating Limits: 

Fluid temperature up to +35

 

Model

HLS-280

HLS-370

HLS-550

HLS-750

HLX-150

HLX-200

HLX-300

Power

W

280

370

550

750

1100

1500

2200

HP

0.37 

0.49 

0.73 

1.00 

1.47 

2.00 

2.93 

Flow

l/h

7800

10800

12900

14400

29000

32000

36000

Head

m

7

9

10

11

16

17

18

Bar

0.7

0.9

1

1.1

1.6

1.7

1.8

Inlet

inch

 1/1/4"

2"

2"

2"

2/1/2"

2/1/2"

2/1/2"

Outlet

inch

 1/1/4"

2"

2"

2"

2/1/2"

2/1/2"

2/1/2"

Solid

mm

N/A

2*2.5

2*2.5

2*2.5

N/A

N/A

N/A

IP 

Grade

IPX4

IPX4

IPX4

IPX4

IPX4

IPX4

IPX4

Weight

Kg

23

18.5

20

21

18.5

19.4

22.4

Impeller

pc

1

1

1

1

1

1

1

Cable

m

1.5

1.5

1.5

1.5

1.5

1.5

1.5

FOB(Shanghai)

Price(USD/pcs)

??

Packing size(m)

q'ty/ctn

4

2

2

2

1

1

1

Length

0.385

0.55

0.55

0.55

0.53

0.53

0.53

Width

0.385

0.42

0.42

0.42

0.31

0.31

0.31

Height

0.45 

0.32 

0.32 

0.32 

0.40 

0.40 

0.40 

m3

0.07 

0.07 

0.07 

0.07 

0.06 

0.06 

0.06 

MOQ

pcs

20

10

10

10

5

5

5

20

pcs

1800

742

742

742

370

370

370

40

pcs

3600

1568

1568

1568

770

770

770

40H

pcs

3600

1792

1792

1792

924

924

924

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Types and differences of pumps
(I) volumetric typeClassification reciprocating rotary typeThe basic principle of reciprocating action by the piston in the cylinder in the cylinder volume changes again, with the suction and discharge of fluid in the shell or the rotor rotating member rotates, the volume of work between rotor and casing changes to the suction and discharge fluid, such as piston pump gear pump, screw pump(two) blade type;The main structure of vane pumps and fans is rotary, bladed impellers and stationary housings that rotate fluid through the impeller to do work, thereby enabling fluids to obtain energy
Q:The water tank of the fish tank does not air out and only has the water outlet
The air inlet pipe is connected with the oxygen burst, the entrance also pulled out, we can see that it is the design of a miter, the oblique incision back to the direction of the water flow speed, this outflow, negative pressure is formed in the oblique incision, the air can be sucked in. As shown.
Q:Why does the centrifugal pump start with a closed valve and the axial pump starts with an opening valve?
Because the characteristic curves of the two are different.The power of centrifugal pump decreases with the decrease of flow rate. When the flow rate is zero, the power is minimum, so the centrifugal pump is started with a closed valve.
Q:What are the characteristics of a vertical multistage centrifugal pump?
A liquid that is primarily diluted, clean, non corrosive, explosive, or similar to water but contains no solid particles or fibers. Because of its high flow and large lift, it is widely used in fire fighting, water supply and air conditioning unit cooling water transportation in high-rise buildings.
Q:Does the control cabinet of the fire control pump need to be related to the fire control room?
The relationship is simple, the fire pump is pressurized water supply device, the control cabinet is the power supply for the fire pump, the regulator tank is to stabilize the pressure of the network management, reduce the pump frequently start device.
Q:What is the pump delivery? What's the difference between years and years?
Secondly, the landlord asked the question, although I did not go to the insurance company to practice the operation, but to my four years of learning, as well as internship experience, or can help you analyze, and I hope to help you.Pay is a one-time payment of premium -- all wholesale D sea n
Q:What are the failures and causes of the replacement of the fuel pump assembly?
Common troubles of gasoline pump:Gasoline pump supply shortage of gasoline pump supply depends on the pump membrane stroke, stroke, pump oil should be more; however, the amount of gasoline pump oil pump will reduce the consumption of gasoline engine, and the fuel pump is inevitable, if the engine fuel consumption, but the actual amount of oil is less, this situation is the amount of oil in the petrol pump, there will be a float chamber of a carburetor oil level is reduced, the engine power shortage.
Q:What is the dry running protector of screw pump? What's the principle and function? Thank you
Principles are generally temperature sensing, such as: when the screw pump by air, the stator and rotor will be heated due to friction,
Q:Why does the centrifugal pump start and close first when the outlet valve is closed?
When the valve is closed off opposite is the first current to the rated current, avoid instant electricity loss of other electrical equipment caused by voltage fluctuation. At the same time, some centrifugal pump outlet check valve is not installed, the role of avoiding the pipeline caused by backflow of water pump reversal.This Regulation (or operation regulation) is generally applicable to larger power centrifugal pumps. For small power equipment, it can be used to determine whether the above operation is necessary for actual use
Q:What are the causes of pump shock?
3. the water pump set screws loose, adjust the concentric, fastening the foot4. pump into foreign body, open cover overhaul5. the flow is too large or too small, adjust the equipment to control the water output

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range