• ZX Self-priming Pump, Self-priming Sewage Pumps, Good Performance System 1
  • ZX Self-priming Pump, Self-priming Sewage Pumps, Good Performance System 2
  • ZX Self-priming Pump, Self-priming Sewage Pumps, Good Performance System 3
ZX Self-priming Pump, Self-priming Sewage Pumps, Good Performance

ZX Self-priming Pump, Self-priming Sewage Pumps, Good Performance

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
400 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

development of pump energy saving products.Self-priming centrifugal pump, the pump and other pump does not have the self-priming capacity, etc.Such as corrosion resistant mechanical seals and stainless steel material can call some of the chemical, pharmaceutical acid and alkali medium. 
Second, the product features
 
1, the pump with self-priming function, do not need to install the bottom valve in pipeline, only to ensure storage in pump body before work are quantitative liquid can have "a drainage, life-long self-priming" function.So both simplifies the pipeline system, and improved the working conditions.
2, has a compact structure, convenient operation, stable operation, easy maintenance, high efficiency, long service life. 
Three, use the product
 
1) suitable for urban environmental protection, construction, fire control, chemical, pharmaceutical, dyes, and dyeing, brewing, electric power, electroplating, papermaking, oil, mining, equipment cooling, tanker unloading, etc. 
(2) apply Yu Qingshui, sea water, chemical liquid medium with acid, alkalinity and with general mushy slurry (medium viscosity 100 mile, or less under the solid content of 30%). 
(3) mount a rocker arm sprayer, the water can go into the air, a small drips to spray, is a good tool for farm, nursery, garden, tea garden. 
And (4) can be matched with pressure filter of any model and specifications, sending size belt filter to filter the most ideal auxiliary pump.  
Fourth, working conditions
 
Traffic: 3 ~ 500 m3 / h
Head: 10 ~ 80 m
Ambient temperature 50 ℃ or less
Medium temperature is 100 ℃ or less
Medium density of 1.24 or less by 103 kg/m3

Q: How can the submersible pump level meter be connected?
Install liquid level controller, two position liquid level sensor, controller to buy manual, wiring according to wiring diagram.
Q: What is the minimum continuous flow of a pump?
At'-- the allowable temperature rise of pumping medium,C- pumping medium specific heat, kj/ (kg DEG C);Ho- off dead center lift, M.Minimum continuous flow minimum continuous stable flow and minimum continuous thermal flow and the maximum value in the selection, or use the pump process, the minimum continuous flow process requirements must be greater than the minimum flow rate of the pump, otherwise it will cause the pump cavitation, vibration and noise, so that the pump parts damaged. If the minimum continuous flow the pump can not meet the minimum requirement's process, can install the bypass reflux device or reflux system in the pump pipeline, to ensure that the minimum continuous flow pump.
Q: What is the name of the day pump and ground pump? Specific introduction
PumpGround pumps are used very frequently in many large basements, because they have no boom, so they need to be taken over manually. In addition to the site, for those days to pump the high-rise buildings, such as 200 meters or 200 meters altitude, can also take over to transport concrete by pump, but the premise is to have enough power to pump concrete will hit above the height and the length of nozzle can reach the height of the floor.Thus, the day pump and ground pump have their respective advantages. The pump is easy to use, but the ground pump can make up for the height that the pump can not reach. At the same time, the price is relatively cheap, so users can choose the corresponding concrete pump when they are in use.
Q: There are 6 pumps, two indoor fire hydrant pumps, two spray pumps, two outdoor pumps, three units, one master and one spare control cabinet. From the control room to the control cabinet, is there only 3 lines or 9 lines?... How do I get it? Where does the hydrant line come from?
You said the three line refers to the control room, the control cabinet, the main pump directly start the straight line of water pump. Each pump should be equipped with single straight line Kai, reported that the cabinet Jinglian dynamic multi line linkage control board has three buttons corresponding to a remote spray pump, fire hydrant pump, pump start outdoor fire hydrant. This requires three straight lines, from the cabinet to the three pump control cabinet, which is the 9 line you call. The water pump control cabinet is provided with a terminal for supplying a remote pump. By looking at the wiring diagram of the water pump control box, you can find the technical personnel of the control cabinet manufacturer if you can't find them.
Q: What does "anti pump" mean in pump operation?
The working process of the main oil cylinder pushing back and forth against the pump when the S valve (C valve or valve or gate valve skirt) reverse swing, so the piston suction concrete cylinder is in the ash conveying pipe is exactly opposite is the pump suction pump (hopper is concrete and push into the hopper, the desizing)
Q: The difference between submersible pumps and centrifugal pumpsWhat's the difference between the two? What is applicable and what?
Difference:The installation position is different: one can discharge water, one is on the ground.The work principle is different: the principle of submersible pump is similar to the electric fan, centrifugal pump through centrifugal force to make the water throw out. According to the principle of centrifugal force design,
Q: Is the vacuum pump air compressor?
A vacuum pump is a device or device that uses a mechanical, physical, chemical, or physical chemical method to pump a vacuum from a container to be evacuated. Generally speaking, a vacuum pump is a device that uses various methods to improve, produce, and maintain a vacuum in a confined space.
Q: What are the application areas of pumps?
1, urban water supply 2, sewage system 3, civil and construction systems 4, agricultural water conservancy system 5, power station system6. Chemical system 7, petroleum industry system 8, mine metallurgy system 9, light industry system 10, ship system
Q: The main factors affecting the performance of centrifugal pumps
Revolutions required to have. It has the following meanings: 1, similar to the geometry of centrifugal pump, everywhere efficiency at the top of the similar condition; centrifugal pump 2, than the number of different, its geometry must be different than the number; the same pump, its shape is similar, but does not rule out the shape similar situation. The following factors are related to specific speed. The specific speed of centrifugal pump has nothing to do with the nature of the conveying fluid, but has a close relationship with the shape of the impeller and the performance curve of the pump. The pump with high specific speed corresponds to the highest efficiency when the flow rate is large and the head is small
Q: The working principle of magnetic pump
Structure characteristics1. permanent magnetPermanent magnet operating temperature range is made of rare earth permanent magnet wide (-45 - 400 DEG C), high coercivity, magnetic anisotropy direction is very good, also won't happen in the same demagnetization phenomenon when is close, is a good source of the magnetic field.2. isolation sleeveIn the metal isolation, isolation sets in a sinusoidal alternating magnetic field, in a cross section perpendicular to the direction of magnetic field lines induced eddy current and converted into heat. Eddy current expression is:. The Pe - K constant; eddy current; rated speed of N - T - pump; magnetic drive torque; F - the pressure inside the sleeve; D sleeve diameter; a material resistivity; and the tensile strength. When the pump design is completed, N, T is the given conditions, to reduce eddy current only from F, D, and so on. Non metallic materials with high resistivity and high strength production isolation, in reducing the eddy current effect is very obvious.