Water Pumps Cheap Centrifugal Best Quality Made In China

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
100 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1.Specifications

1)High performance
2)Mechanical seal
3)Cast iron impeller or bronze impeller
4)Lower vibration water pump
5)Large flow

2.Packaging & Delivery

Packaging Detail:

export wooden cases

Delivery Detail:

within 30 days once receipt of 30% T/T prepayment

BPO Irrigation Centrifugal Split Water Pump

3.FEATURES

BPO series single-stage double-suction open type centrifugal pump self-researched by the Company after absorbed advanced technology of similar products and combined application requirement of various customers. The series pump adopts excellent hydraulic model, wider type spectrum and better structure. Pump casing is produced by special machine tool, which ensures concentricity among shaft bearing, shaft and pump case, and provides better reliability and maintainability. Apply to municipal water supply and drainage, water circulation of air conditioner, agricultural hydraulic engineering, such as irrigation, drain flooded fields etc., industrial water supply system, firefighting system, water supply and drainage of
heating system, transportation of clean water

4. OPERATING CONDITION

a)Rotate speed: 2950r/min, 1480 r/min, 980 r/min, 730 r/min
b)Flow range: 64.4~9810m3/h
c)Delivery lift: =200m
d)Medium temperature: =80 ,
e)product adopting special materials: -20 ~120
f)Ambient temperature: Lower than 40
g)Operating pressure up to achieves 2.5MPa

5. MATERIAL 

a)Pump casing: Cast iron or magnesium iron
b)Pump cover: Cast iron or magnesium iron
c)Impeller: Cast iron, magnesium iron or tin bronze
d)Sealing ring: Cast iron or tin bronze
e)Pump shaft: 45# steel plated with chrome
f)Dynamic and static mechanical sea: Hard carbide, graphite
g)Configuring other material according to requirement is allowable

Rated flow

10(m3/h)

Rated head

26m

Rated power

1.5Kw

Voltage

220V

Rated Current

7.2A

Rated speed

2860r/min

Discharge diameter

50mm

6.Conditions of use

Pumps used in the following conditions should be continuously to work properly: 
1. For water pumps suitable medium, medium temperature shall not exceed + 40°C
2. The medium PH value between 6.5 ~ 8.5 
3. The volume of medium containing solid impurity is less than 0.1%, the size is not more than 0.2 mm 
4. The power frequency 50 hz, voltage for single-phase 220 v, 380 v, three-phase voltage fluctuation range for rating of 0.9 to 1.1 times 
5. Diving depth of no more than 5 m, is not suitable for irrigation and drainage of sewage and chemicals.

Water Pumps Cheap Centrifugal Best Quality Made In China

Water Pumps Cheap Centrifugal Best Quality Made In China


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Sewage treatment plant design how many pumps should be selected, head how to calculate the maximum design flow is 833M3/h
Maximum design flow of sewage treatment plant is 833m^3/h, water pump can choose 2 or three units, the flow rate is 1000m^3/h. The amount of information in the head according to the problem can not be determined.Sewage treatment plants, water plants and other pumps are the key equipment, usually 1~2 units standby. Therefore, to choose 2 or three units of the same type of pump, each pump flow should be able to meet the use requirements. General pump selection, the pump rated flow should be 1.1 times the design flow of sewage treatment plants, that is, 833x1.1=916 (m^3/h), round 1000 (m^3/h).Pump head should be based on the actual work lift h determined. When calculating the actual lift, we should not only consider the actual geometric elevation difference of the pump installation, but also consider the factors such as pipe water loss and elbow water loss. The rated lift of water pump must have a certain margin, generally choose 1.1h, h for the actual required lift.
Q:Variable flow variable frequency water pump how to adjust the flow?
Flow plus transmitter control
Q:Intelligent pump controller, water is full water transfer automatically shows the next pool of water shortage, what is the matter?
The high and low level values are set back.
Q:Can the water from the fire pump enter the roof fire tank? Why?
This should be divided into two cases, the key depends on the use of your water tank!If you fire water tank roof is a constant pressure water tank fire control system, the requirements must be set on the water tank outlet check valve, which can only flow from the tank outflow, then pump the water can not enter the roof fire water tank.If the roof fire water tank acts as a water transfer tank and uses it to transport water to a higher building, the fire pump water can enter the water tank
Q:Does the lift of pump relate to the water level of import and export?
The head of centrifugal pump has nothing to do with the water level of the inlet and outlet. When the water pump installation position is lower than the pool water level, you can enter the pump by gravity, and when the pump installation position is higher than the water level of the pool, it depends on the pump suction process, the effect is good.
Q:Should the no-load power of the pump be equal to the rated power?
We must first clear the meaning of rated power; rated power is called the reference numerical electrical power consumption in the voltage conditions specified, and the actual power consumption of electrical appliances is different in different situations, the pure resistance (such as lighting, electric) as long as the voltage conditions, the actual consumption of electric power close to or equal to the rated power, and for appliances like motor, electric power consumption, not only related with the voltage, but also with the relevant load. For example, someone with 200 pounds of energy, then the person in the condition of small meal, maximum load of 200 pounds, but if you take as long as he is 100 pounds, of course he relaxed, he would not say must bear 200 pounds!You measure the pump power is less than 1200W, first you did not mention your use of voltage is not rated voltage, then you don't want him full load, the suction is far less than 8 meters, there is no mention of whether you send water to 50 meters (Yang Cheng), there may be insufficient voltage, and you have don't need it so much power consumption. Of course, one advantage is that it doesn't burn easily. It is easy to burn if it is used at full load.
Q:What is the definition of the pump in the capacity of the pump?
I don't know very well about your work there;General pump is a one, or two with a preparation work; pump and standby pump capacity is big, the maintenance of pumps is provided here, said in the overhaul, overhaul maintenance enabled pump, pump capacity can be greatly reduced, as long as the pump 1/4, thus reducing the volume of the standby pump the.
Q:What will the water pump reversal situation?
Reversal will also water out, but the amount of water is small, belong to "pressure water" effect, as if a basin of water, we do not shoot outward and down, the water will be out of the basin.
Q:Three phase water pump rated power 4000W, is three-phase working water pump, the voltage is 380V, how to find the three-phase pump current, and calculation of public
Three phase water pump motor rated power 4000W is the output shaft power, divided by the motor efficiency (general 85%) is the input power, which is often mistaken. The electric power is =4000/0.85=4706WRated current = electric power /1.732x, rated voltage x, power factor =4706/1.732x380x0.8=8.94A (assuming power factor 0.8).The above three answers are all wrong.
Q:Pump power ratio design is small, the problem is big?
No problem, despite the good use of different water pump factory manufacturing process is different, the product of the rich value of different factors, power difference is inevitable, as long as the flow and head to meet your use requirements.The calculation formula tells you: your flow is 72 tons / hour, lift 90 meters, motor power P=2.73HQ/0.75*1.2=28.5KW

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range