10KVA UPS Price with High Quality
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 Piece pc
- Supply Capability:
- 2000 Pieces per Week pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Outstanding feature
1. Texas Instruments processor
2. Motorola Microprocessor
3. Module design
4. Advanced Current Control
5. IGBT power component
6. Power Factor Correction
7. Online Maintenance
8. High frequency and double conversion on-line technology
9. Advanced PFC technology
10. EPO Function
11. Wide input voltage range
12. Fully digitized microprocessor control
13. Parallel redundancy
14. Advanced battery management
15. Lightning and surge protection, short circuit and overload protection
16. Multilingual LCD display
Technical specification
MODEL | 6K(S)L | 10K(S)L | 3CRT10KSL | 3CRT15KSL | 3CRT20KSL |
Power(VA/Watt) | 6000VA/4200W | 10000VA/7000W | 10000VA/7000W | 15000VA/10500W | 20000VA/14000W |
INPUT | |||||
220 VAC, 1 Phase + Neutral | 220 VAC, 1 Phase + Neutral | 380 VAC, 3 Phase + Neutral | 380 VAC, 3 Phase + Neutral | 380 VAC, 3 Phase + Neutral | |
Voltage Tolerance | 176 – 276 VAC ± 3% | 176 – 276 VAC ± 3% | 304 – 478 VAC ± 3% | 304 – 478 VAC ± 3% | 304 – 478 VAC ± 3% |
Power Factor | ≥ 0.98 | ≥ 0.98 | ≥ 0.95 | ≥ 0.95 | ≥ 0.95 |
Current (nominal) | 23 Ampere | 37 Ampere | 13 Ampere / Phase - 39 A | 23 Ampere / Phase - 69 A | 30.3 Ampere / Phase - 91 A |
Input Fuse | 32 A NFB | 50 A NFB | 63 A NFB | 100 A NFB | 100 A NFB |
Frequency & FrequencyRange | 50 Hz, 46 ~ 54 Hz | ||||
Perfect Voltage and frequency Compatibility | |||||
0.65 inductive - 1.0 resistive | |||||
Sinusoidal | |||||
220 / 230 / 240 VAC ± 1% | |||||
At 50% - 100 - 50% unbalanced load, max voltage decline < ± 5% | |||||
At Dynamic load Changes, Output Voltage recovery time is 60 msec ± 1% | |||||
For Linear Load ≤ 2%, Non Linear Load ≤ 6% | |||||
50 Hz / Mains 46-54 Hz, Battery Mode ± 0.1% (0.05 Hz) | |||||
3:1 | |||||
For 105% - 130% load 10 mins., for > 130% load transfer to bypass after 1 sec, shutdown after 1 min at overloaded bypass | |||||
At > 105% load shut down after 10 sec. | |||||
Standard static bypass, Completely Uninterrupted transfer between Mains - Battery / Battery - Mains | |||||
176 – 261 VAC, 1 Phase + Neutral | |||||
Maintenance Free, Dry Type | |||||
240 VDC | |||||
LCD Panel | |||||
Push Buttons (Open / Close, Audible Alarm Cancellation) | |||||
% Load, Input Voltage Exist, Output Voltage Exist, Bypass Active, Battery Mode, Battery Capacity (%), Inverter in Service, Fault | |||||
Mains On, Mains Reverse, Battery Mode, Bypass On, Load / Battery Level, Overload, Fault | |||||
Electronic Protection is available. In case of exceeding limits, the load is transferred to bypass without any interruption | |||||
Inverter shuts down automatically | |||||
If the internal Temperature is 90°C the load is transferred to bypass, When it returns < 80°C, Inverter starts to work | |||||
Modem / Network protection input against to Voltage Spikes | |||||
Buzzer, it can be switched off by audible alarm button. | |||||
Battery Mode, Battery Low, UPS fault, Overload, Short Circuit, Over Charge, Charger, Bypass, Inverter fault, Communication fault | |||||
Standart DB 9 (Female) Port, Intelligent RS232 (standard), SNMP(optional) and DB25 parallel port (for paralelling, optional) | |||||
Winpower-XP | |||||
88% | |||||
≤ 55 dBA | ≤ 60 dBA | ||||
EN 61000-4-2 (ESD), 4-3 (RS), 4-4 (EFT), 4-5 (surge), IEC 62040-2 (EMI) | |||||
0 °C ~ 40 °C, maximum 20-90% (Non Condence) | |||||
-20 °C ~ +70 °C | |||||
IP20 | |||||
Forced cooling with variable speed fan according to load % | |||||
≤ 1000 meter (from the sea level), at nominal load | |||||
260x717x570 | |||||
35 / 84 | 38 / 93 | 38.5 | 55 | 55 |
- Q:How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
- The number of tables in this table is increasing when the table rings to show 1.Method 2 is only to measure the capacitance is good or bad, can not be measured capacity.
- Q:Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
- Double winding type safety isolating transformer load end and the power supply terminal is not connected, is safe, and autotransformer primary winding of a share, it is directly connected with the power supply end of the power, not safety.
- Q:Why should lighting transformers be used in factories and mines?
- In some factories and mines (such as power plants), in order to supply power reliability, the power system is grounded in a three-phase, ungrounded, or neutral manner. In this way, the transformer must be connected to a neutral grounding type with a special transformer to supply power to the lighting.
- Q:What type of low voltage transformer should be adopted for safety lighting power supply?
- Isolated transformer, once 380V or 220V, two voltage, 36V, 24V, 12V, several categories, do not allow the use of autotransformer.
- Q:How many A leakage protection switches are used in 5000VA lighting transformers?
- Secondary current =5000VA/220=22A, you can select the 32A leakage protection switch.
- Q:What transformer can be used in a safety voltage lighting transformer?
- 220V/36V or 24V isolation transformer. Double winding, high and low voltage coils, not connected.
- Q:Power and lighting transformers, lighting quality will be affected much?
- Corresponding to the transformer power supply, in order to save costs and reduce costs, the choice of AC ignition method is better. Pure resistive load, the power factor is 1. The 3 *100W=300W is the capacity of the required transformer
- Q:Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
- What you think? Your light is 220V, right. Over 36V, it's better not to live with electricity unless there is good protection
- Q:Does the lighting work properly? Doesn't that power equipment start voltage unstable?
- It is not easy to control, the power and lighting and electricity; if the transformer capacity is small, and relatively large power equipment start frequently, voltage stability will be poor, the lamp brightness will fluctuate dramatically, have effect on visual acuity. But as long as the design is reasonable, it has little effect.
- Q:How many can you bring with 220V? How many can you bring with 380V? There are 3 terminals on the transformer. There are 220V, 380V, 0, three terminals. 220V is the 220V terminal and the 0 connection. How can the 380V be connected? Is it 380V and 0 or 380V and 220V?
- Connect 220V method, FireWire 220V terminal, zero line 0 terminal, 380V terminal is not connected.Connect 380V method, A phase 380V terminal, B phase 0 terminal, 220V terminal is not connected.
1. Manufacturer Overview |
|
---|---|
Location | Guangdong,China (Mainland) |
Year Established | 2000 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | 10.00% North America 10.00% South America 10.00% Southeast Asia 10.00% Mid East 10.00% Eastern Asia 10.00% Africa 5.00% Eastern Europe 5.00% Western Europe 5.00% Central America 5.00% Northern Europe 5.00% Oceania 5.00% Southern Europe 5.00% South Asia 5.00% Domestic Market |
Company Certifications | ISO 9001:2000;ISO 14001:2004 |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | Guangzhou |
Export Percentage | 51% - 60% |
No.of Employees in Trade Department | 11-20 People |
Language Spoken: | English, Chinese |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
10KVA UPS Price with High Quality
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 Piece pc
- Supply Capability:
- 2000 Pieces per Week pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches