XD series vacuum pumps
XD series vacuum pumps are available for low and medium vacuum fields, which are mainly used for pumping air and other dry gases rather than corrosive, toxic, flammable and explosive gases. Furthermore, they cannot pump the gases containing tiny particles or dust and cannot transport other small objects.

XD series vacuum pumps can work for long term in the well-ventilated room with ambient temperature of 5-30 and with humidity 80%.

In addition to the above applications, the XD series vacuum pumps can be available other applications, such as:

1. To increase the amount of the pumping gas and to improve the vacuum degree, please combine with Roots pumps to form a unit for this.

2. If pumping moist air or condensable gas, the condenser can be installed before the vacuum pump and the gas ballast valve is installed on the vacuum pump.

3. If pumping the gases containing dust particles, the dust filters can be installed in front of the vacuum pump.

4. If pumping the corrosive gases, the corrosion-proof gas filter can be installed in front of the vacuum pump.


List of performance

Parameters

Model

XD-020

XD-040

XD-063

XD-080

XD-100

XD-160

XD-202

XD-250

XD-302

Pumping rate

(m³/h)

20

40

63

80

100

160

200

250

300

Pressure limit

(mbar)

0.1~0.5

0.1~0.5

0.1~0.5

0.1~0.5

0.1~0.5

0.1

0.1

0.1

0.1

Motor power

(kw)

0.75

1.5

2.2

2.2

3

4

4.5

5.5

7.5

Motor speed

(r/min)

2880

1440

1440

1440

1440

1440

1440

1440

1440

Noise (db)

≤62

≤65

≤65

≤65

67

70

72

73

75

Allowable steam pressure

(mbar)

40

40

40

40

40

40

40

40

40

Pumping water steam

(kg/h)

0.3

0.3

1

1

1.6

2.5

4

4.5

5

Working temperature

()

82

80

80

80

84

95

95

81

83

Oil volume

(L)

0.5

1

2

2

2

5

5

7

7

Weight

(kg)

18

45

55

60

70

150

150

195

211

Air intake thread

Rp3/4’’

Rp1/4’’

Rp1/4’’

Rp1/4’’

Rp1/4’’

Rp2’’

Rp2’’

Rp2’’

Rp2’’

Overall dimensions

L * W * Hmm

650*300*280

650*300*280

650*430*295

650*430*295

720*430*295

850*505*440

850*505*440

980*560*440

1010*560*440



Q:What's the difference between a centrifugal pump and a centrifugal pump? What are they used for?
Centrifuges are generally used to classify liquids of different densities in liquids.
Q:Piston filling and peristaltic pump filling which precision is high?
First of all, we should know the working principle of each, and analyze the accuracy from the principle, this problem is very important. Piston filling, such as the injection of drugs that we have been ill, the accuracy of the piston pump depends on the accuracy of the motor and the area of the unit cross section
Q:A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
According to the water quantity form fire flow water supply system fire safety in high-rise building fire hydrant pump lift is 10L/s, accurate algorithm is to say after a simple calculation with each indoor hydrant flow is two 5L/s bolt so to get the most unfavorable point for the calculation unit to calculate the minimum requirements, with the most unfavorable point suppository pressure specifications 0.07MPa, partial loss of the most unfavorable line and the line (according to the equivalent length) and loss (according to the material resistance coefficient), and finally the pump head loss of gravity difference. But we just calculate the construction elevation difference multiplied by 110% to 120% to determine the head {there is a need to know is: conversion head (m), (kg) and MPa kg 1MPa=10 kg = 100m is the vertical water column on unit area pressure conversion
Q:What's the word "pump"? Is that what advocates mean?RT
Is generally believed that the "wholesale" is the "hoarding" of "hoarding" variant, can be used to replace the word "store". And "wholesale" compared to "store" is clearly better and better recognize, because the "store" is a phonogram, hoard shaped characters "mouth", said the biggest the range of aggregation, like a grain bin; "Tun" is also phonetic, semantic. Tun, originally refers to the grass speared out of shape, with curly tails, and gathered the meaning.In this case, the "fans" can be written as "Yong Tun". But this is also troublesome, because the "store" in addition to read "Tun" (Ping Sheng), another pronunciation of "Dun" (Qu Sheng), who said food utensils, when we had the "Valley" store. So, if the "fans" to "hold", is also wrong. "Bin Zhao Wei fans" although it sounds strange, but at least not ambiguous; if changed to "Zhao Wei", is that we have to hoard may hear "Zhao Wei" or "Zhao Wei hold hip", hold the shield this is not the more the more chaotic change it!It is suggested that the "fans" to "fantastic", the modified method was acceptable. In modern Chinese, "public" does not necessarily mean that many, can also refer to a single. "One of the masses", "one of the audience (or audience)" this kind of argument, has been about good. Since this kind, we say "a fantastic" what not? "Fantastic" at least than the "fans" straightaway. The problem is, the word and Hong Kong Standards, there is no "fantastic".
Q:What does the pump mortar do?
1: 2 cement mortar or cement mortar with the same proportion of other components except coarse aggregate in the concrete, the pump piston and the inner wall of the pipeline are fully lubricated, and a layer of lubricating film is formed
Q:Why does the centrifugal pump close the pressure to start?
The motor power is selected according to the rated flow of shaft power points plus 15 to 25%, if the outlet valve is fully open to start, the pump flow may deviate from the amount of fixed lot, pump efficiency also reduces a lot, resulting in shaft power greater than the motor power caused by tripping even burned electric machine.
Q:What should I pay attention to when buying a pump?
Two, the first choice of large and medium-sized professional manufacturers, and through the quality identification of relevant departments, the market credibility of the better models, but also to the professional quality inspection institutions consultation.Three, check the motor grounding device for electric pump, water pump and motor axis, the motor should be in a proper position is provided with a grounding screw, and the grounding screw are arranged near the ground; grounding device of small submersible pump should be reliable and grounding wire, grounding wire cables should have the obvious grounding mark the flag should be in use; the motor is not easy to be worn during the period. This is one of the important safety indexes of electric pumps.
Q:Water pump outlet valve sequence
Design specifications detailed manual instructions, divided into two cases:1, pump water first check valve, suitable for small caliber pipeline, gate valve to protect the non-return valve, not damage function;2, pump water out of the first gate valve, check valve for large diameter pipe, at this point valve easy to open and close;The setting of the check valve is mainly to avoid the high reverse speed of the pump and the condition of the submerged pump house. Set in the suction port of the pump, then stop the pump water flow will still affect the pump. In addition, the pump suction should try to avoid installing too many pipe fittings, so that the pump can maintain sufficient cavitation margin.
Q:Harm of air pump and pump
Centrifugal pump situationEmpty pump is divided into two kinds, if there is no liquid, then it will cause the mechanical seal of the pump to overheat, wear and even die
Q:Is the flow meter in front of the pump or after the pump?
After the flowmeter is placed in the pump, it is better to add a pressure tank or a buffer tank, so that the flow meter will work better

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords