Specifications of Wafer Type Check Valve
valve type: wafer, nominail pressure: 1.0/1.6MPa, DN50-DN400, certificate: ISO9000, ISO40001, CE, API, EN1074
series: Dual plate check valve
1) Size: DN40-DN400
2) standard: API594 ANSI 16.34
3) pressure standard: API598
4) face to face: ISO5752, DIN3202
5) body: cast iron/ductile iron/WCB
6) Seal ring: NBR/EPDM
7) Shaft: Carbon Steel/stainless steel
8) suitable temperature:-15~150
- Q: What kind of check valve is used in the sewage pump of sewage treatment plant?
- 2. installation of pump outlet check valve*Swing check valves are generally mounted on horizontal pipes: for bore DN~80mm check valves, they can also be mounted on vertical or upward sloping pipes.*Straight through lift check valves shall be installed on horizontal pipes; vertical lift check valves must be mounted on vertical pipes and medium upward flow.*As the check valve is easy to damage, therefore, should be installed near the pump outlet valve, in the upper part of the check valve with a cut-off valve (general use of ball valve or gate valve), easy to overhaul.*To facilitate the relief of the check valve before disassembly, the relief valve shall be installed between the check valve and the shut-off valve.
- Q: Why can't the check valve on the air pipe be used when the wind speed is less than 8 meters?
- First of all, you must understand the working principle of the check valve, indeed, as you said, you can adjust the position of the hammer by adjusting the position of the drop hammer.If you are in their own design and production, consider the thickness of the blade, drop hammer size, weight, and other parameters considered.Hope to be of help to you!
- Q: Check valve does not automatically check back, how to adjust?
- 4 the vertical lift check valve shall be mounted on a vertical pipe.5, the lift type horizontal check valve shall be installed on the horizontal pipe.6. Do not check the weight of the valve in the line. The large check valve shall be independently supported so as not to be affected by the pressure caused by the piping system.
- Q: What is the difference in price between the check valve HH48X-10C and the HH49X-10C?
- Since this model has exceeded the standard requirements, so there is no uniform manufacturers. There are dozen HH49X, there are also playing HH48X, HH49X, in fact, are the same kind of valve.
- Q: What are the types of check valves?
- Taiwan reasonable, this may not have domestic, if you can name, you can call three one-way valve, we can see in accordance with the structure of the spring type.Front Ze valve provides: hope to adopt!!!I hope I can help you.
- Q: Which side of the gate is the fire check valve in the pump room?
- The check valve is installed between the shock absorbing flexible joint and the water outlet control valve at one side of the water outlet pipe of the water pump
- Q: How to install fire fighting pipe and flue fire check valve?
- 4, the installation of flue should each layer as bearing, bearing steel 2 root diameter over 14mm?.5, after the installation of the flue, in each flue check valve of the reserved installation of fire type flue check valve, with special glue mixing cement, coated with a check valve installed in the valve hole edge, and then back to the reservation in check at.6, the construction should be reserved at all levels of the hole, covered with a cover plate, to ensure safety in construction, to prevent construction waste fall into the flue.
- Q: Is it better to have explicit rules in the relevant specifications? Thank you, ah, ah, urgent.
- 8.5.3.2 through ventilation, air conditioning room and important or fire danger room, partition and floor.8.5.3.3 vertical air duct with horizontal pipe section at each level of the horizontal air pipe.8.5.3.4 passes through both sides of the deformation joint.8.5.4 fire valve action temperature should be 70 degrees.
- Q: What's the difference between the H76H model and the H76J check valve?
- Check valve additional number: HH, micro resistance, slow closing check valve, BH Insulation check valve, HQ ball type check valve;The check valve type: H on behalf of check valve;The check valve flange connection: 4, 6, 7 for welding clamp;The check valve: 1 lift, 2 vertical, 4 swing, 6 double disc, 8 butterfly;The check valve seal: B Babbitt, F fluorine plastic, H stainless steel, Monel alloy, cast M direct machining of X rubber, Y hard alloy, W;The check valve pressure: 16 pressure of sixteen kg,
- Q: How does the check valve work?
- Check valve refers to rely on the flow of the media itself and automatically open and close the valve flap, used to prevent the media back flow valve, also known as check valve, Dan Xiangfa, counter flow valve and back pressure valve. The check valve belongs to an automatic valve, whose main function is to prevent the backflow of medium, prevent the reverse of pump and drive motor, and release the container medium. The check valve can also be used to provide a supply to the auxiliary system where the pressure may rise above the system pressure. The check valve can be mainly divided into swing check valve (rotating by gravity center) and lift check valve (moving along the axis).The function of this type of valve is to allow the medium to flow in one direction and to prevent flow in the opposite direction. Usually the valve is automatically work, fluid pressure flow in one direction, the valve open; the opposite direction of fluid flow by gravity, fluid pressure and valve closing effect on the valve seat, thereby cutting off flow.Among them, the check valve belongs to this type of valve, which includes swing check valve and lift check valve. The swing check valve has a hinge mechanism and a gate like valve free against the inclined seat surface.
1. Manufacturer Overview
Location | Jiangsu,China |
Year Established | 2001 |
Annual Output Value | US$10 Million - US$50 Million |
Main Markets | North America South America Eastern Europe Southeast Asia Africa Oceania Mid East Eastern Asia Western Europe |
Company Certifications | ISO9001 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | English |
b) Factory Information | |
Factory Size: | |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered |
Product Price Range | High and/or Average |
Send your message to us
Wafer Type Check Valve
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 10 Pieces pc
- Supply Capability:
- 40 Tons Per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords