• Top quality Parallel Thread Rebar Coupler System 1
Top quality Parallel Thread Rebar Coupler

Top quality Parallel Thread Rebar Coupler

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1.Material:45#high quality carbon steel.

2.Application: 12--50mm.

3.High strength,low cost,simple operation.

1#

Coupler SizeOuter Dia(±0.5mm)Inner Dia(±0.5mm)Length(±2mm)Thread Pitch(mm)Thread Angle(º)Weight/Pc(kg)
D121910.2835M12*1.75P60/750.036
D142112.5538M14.8*2.5P60/750.068
D162414.5043M16.8*2.5P60/750.099
D182716.3548M18.6*2.5P60/750.125
D202918.4553M20.6*2.5P60/750.180
D223320.3558M22.6*2.5P60/750.205
D253723.1563M26.0*3.0P60/750.317
D284125.9568M28.6*3.0P60/750.399
D324730.1580M32.8*3.0P60/750.640
D365433.8583M36.7*3.5P60/750.900
D405937.5588M40.4*3.5P60/751.099
D507447.10125M50.4*3.5P751.298

3#

Coupler SizeOD(±0.5mm)Length(±2mm)Thread PitchThread Angle(º)G/W(kgs)
D1422382.5750.068
D1625432.5750.099
D1828482.5750.125
D2030532.5750.180
D2234582.5750.205
D2538633.0750.317
D2842683.0750.399
D3248803.0750.640
D3655833.5750.900
D4059883.5751.099

Rebar Coupler Advantages:

----Adopt National Standard 45# igh quality carbon steelas raw meterial.

----High strength, tensile test usually more than 600Mpa,Tensile strength can reach 110%of yiled strength of parent rebar.

----The product has passed ISO9001 International Quality System Certification.

----We can design,produce weldable or other type rebar couper as per customers` requirement.

Tengzhong Machinery Co.,Ltd

A processional  manufacture of rebar mechanical splicing equipment,rebar processing machinery,rebar coupler and related products.It is a membership of construction machinery trade of China quality cotrol association.

Q:How do steel tube couplers prevent accidental dislodging or separation of scaffolding components?
Steel tube couplers prevent accidental dislodging or separation of scaffolding components by securely connecting and interlocking the tubes together, providing a strong and stable structure. These couplers are designed to withstand heavy loads and external forces, ensuring that the scaffolding remains intact and safe during use.
Q:Can steel tube couplers be used in scaffolding projects with uneven loads?
To ensure the stability and safety of scaffolding projects with uneven loads, it is crucial to properly design and rate the steel tube couplers used. Careful calculation and distribution of the loads, along with the use of appropriate bracing and support systems, are necessary to maintain stability. Regular inspections and maintenance are important for detecting any signs of strain or failure. Consulting with experts in scaffolding design and construction is advisable, particularly for projects with uneven loads. Ultimately, proper planning, design, and maintenance are vital for the safety and stability of the scaffolding structure.
Q:How do you properly secure steel tube couplers in scaffolding?
In order to properly secure steel tube couplers in scaffolding, it is important to follow a series of steps: Firstly, before attempting to secure the couplers, it is essential to ensure that the scaffolding structure is stable and correctly assembled. All components must be in good condition and free from any defects. Next, position the steel tube coupler at the desired location on the scaffold tube. It is crucial to ensure proper alignment and that the teeth of the coupler are facing the tube. To tighten the coupler, utilize a spanner or wrench to rotate the bolt on the coupler. Apply sufficient force to securely fasten the coupler to the scaffold tube, taking care not to over-tighten, as this could potentially cause damage to either the coupler or the tube. Once the coupler is securely fastened, inspect for any signs of movement or looseness. If there is any play or wobbling, re-tighten the coupler to ensure a secure fit. Repeat this process for all other steel tube couplers in the scaffolding structure, ensuring that each one is properly aligned and securely fastened. During use, it is important to regularly inspect the couplers for any signs of wear, damage, or loosening. If any issues are detected, it is imperative to immediately replace the coupler to maintain the integrity and safety of the scaffold. To ensure the correct and secure installation of couplers, it is crucial to follow the manufacturer's instructions and industry guidelines. Additionally, it is highly recommended to receive proper training and certification in scaffolding erection and safety.
Q:How do steel tube couplers prevent tubes from separating under load?
By creating a strong and secure connection, steel tube couplers prevent the separation of tubes under load. These couplers are specifically designed to join two or more steel tubes together, ensuring their rigidity and stability even when exposed to heavy loads or external forces. One of the main advantages of steel tube couplers is their ability to mechanically interlock the tubes. This means that the coupler physically grasps the tubes, establishing a tight and dependable connection. This interlocking mechanism can be achieved through various methods, such as threaded connections, bolted flanges, or internal wedges. Regardless of the specific design, the primary objective is to generate a frictional force between the coupler and the tubes, preventing any relative movement or separation. Moreover, steel tube couplers often incorporate additional features to improve their load-bearing capacity. For instance, some couplers may include internal or external reinforcement plates that evenly distribute the load across the joint, minimizing stress concentrations. Others may have special sealing mechanisms to prevent the entry of moisture, corrosion, or other contaminants that could weaken the joint over time. Furthermore, steel tube couplers are typically manufactured from high-strength materials, such as carbon or alloy steel, which can withstand significant loads without deforming or failing. These materials possess excellent tensile strength, enabling them to handle the forces exerted on the joint and resist any tendency for the tubes to separate. Couplers are also frequently designed with safety factors to ensure a sufficient margin of strength against expected loads, further reducing the risk of separation. In conclusion, steel tube couplers prevent the separation of tubes under load by establishing a secure mechanical interlock, distributing the load effectively, utilizing high-strength materials, and incorporating additional features to enhance durability and safety. Through the combination of these elements, steel tube couplers guarantee a firm connection between the tubes, even in demanding applications and adverse conditions.
Q:Water conservancy project construction process, how to calculate the full capacity of the red scaffold capacity. I have no wealth value, please expert guidance.
Is specialized in the production of rock wool sandwich panels, rock wool sandwich panels with fire, thermal insulation, sound-absorbing sound insulation, beautiful appearance, convenient construction, green, and so on. Excellent performance. Widely used in large industrial plants, warehouses, gymnasiums, supermarkets, hospitals, cold storage, activities room, building plus layer, clean workshop and the need to heat insulation fire places. Hope to help you, if there is any doubt, look at our company's website, the above details of the product, in the Google search company name will be able to find, I wish you a good mood.
Q:What are the maximum allowable tolerances for steel tube coupler connections?
The maximum allowable tolerances for steel tube coupler connections depend on various factors such as the specific application, industry standards, and regulatory requirements. However, in general, the maximum allowable tolerances for steel tube coupler connections typically include considerations for dimensional tolerances, alignment tolerances, and surface condition tolerances. Dimensional tolerances refer to the allowable variation in the dimensions of the coupler and the tube. These tolerances ensure that the coupler and tube can be properly fitted together without significant gaps or misalignment. The specific dimensional tolerances may vary depending on the size and type of the coupler and tube, but typically they are expressed as a percentage or a specific measurement range. Alignment tolerances are crucial for ensuring the proper alignment and positioning of the coupler connection. They specify the acceptable angular deviation or misalignment between the connected tubes. The alignment tolerances can be specified in terms of degrees or as a maximum allowable gap between the tubes. Surface condition tolerances relate to the quality and condition of the surfaces that come into contact during the coupler connection. They outline the permissible surface roughness, imperfections, and defects on the coupler and tube surfaces. These tolerances ensure that the connection remains structurally sound and can withstand the intended loads and environmental conditions. It is important to note that specific industries, such as construction or oil and gas, may have their own standards and guidelines that define the maximum allowable tolerances for steel tube coupler connections. Therefore, it is recommended to consult relevant industry standards or regulatory bodies to obtain the most accurate and up-to-date information regarding the maximum allowable tolerances for specific applications.
Q:Are steel tube couplers resistant to humidity or moisture?
Yes, steel tube couplers are generally resistant to humidity or moisture. The corrosion-resistant properties of steel make it less susceptible to damage from moisture, making it a suitable choice for applications in humid or moist environments. However, regular maintenance and protective coatings may be necessary to ensure long-term durability and prevent any potential corrosion.
Q:The whole of my ear (except lobes) is very sore, im not touching it or anything though , is that normal ? I got it done yesterday.
Yup that sounds about right. You have to understand, you just had two cartilage piercings done; as piercings go, cartilage is about the most traumatic thing you can pierce on your body (except for very exotic and extremely rare piercings). You also have to understand, that inserting the single barbell into two fresh cartilage piercings is pretty traumatic too. So an industrial is like a double wammy for your ear. My industrial made half my head sore for a couple of days lol. So I'd say you're probably fine. Don't worry.
Q:Can steel tube couplers be used in both single and double coupler configurations?
Yes, steel tube couplers can be used in both single and double coupler configurations. Steel tube couplers are versatile and can be used to connect two tubes either end to end (single coupler configuration) or at a right angle (double coupler configuration). They are commonly used in construction and scaffolding applications to create sturdy and secure connections between tubes. Whether you need to join tubes in a straight line or create a 90-degree angle, steel tube couplers are a reliable and efficient option.
Q:Section of the 1.8M * 2.4M, the length of 7 meters frame beam how to support?
To steel pipe fastener type support, wooden plywood template as an example 24m high beam, you can consider setting the level of construction joints, layered pouring, for example, two times So the requirements of the template will be greatly reduced The following is a pouring to consider the template stent Feeling, 600X600 spacing can be erected This horizontal horizontal row of steel pipe Did not pass the calculation review Sweep bar, horizontal bar, scissors support and other bar settings see specification the pole with the top care, top care set 100X100 beam horizontal wooden side as the main keel, the top of the beam set by 40X60 wooden side @ 300 side mold reinforcement Beam bottom side mold set step by step Set the pull bolts to a height of 300 steps As the beam width of 18 meters, to be carefully set Appropriate plus bracing

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords