• Swing Check Valve for Oil ISO5208  High Quality China System 1
  • Swing Check Valve for Oil ISO5208  High Quality China System 2
  • Swing Check Valve for Oil ISO5208  High Quality China System 3
Swing Check Valve for Oil ISO5208  High Quality China

Swing Check Valve for Oil ISO5208 High Quality China

Ref Price:
$400.00 - 900.00 / pc get latest price
Loading Port:
Tianjin
Payment Terms:
TT or LC
Min Order Qty:
100 pc
Supply Capability:
1000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Quick Details of Swing Check Valve

 

Standard or Nonstandard:

Standard

Structure:

Check

Pressure:

Normal

Power:

Manual

Material:

Stainless Steel, Ductile Iron

Temperature of Media:

Normal

Media:

Oil

Place of Origin:

China

Brand Name:

Yue

 

Packaging & Delivery of Swing Check Valve

Packaging Detail:

Plywood case & carton

Delivery Detail:

10-40days

 

Specifications of Swing Check Valve

 

Size: 2"-30"

Rating: Class 150-1500

 

Design & Manufacture: API, ASME B 1610, BS 1868

 

Face to face dimension: API 6D

 

Usage/Applications Of Swing Check Valve

 

-Various modes of the pipeline, prevent the medium backflow

 

- Products Design Features: Flanged & Butt-welding ends swing check valves are used in pipes under pressures between 

  PN 1.6-16.0MPa,Class 150-900Lb,working temperatures between -29-570 °C, They are used in industries include oil, chemistry, pharmaceutical, fertilizer.

 

- Operation: Handle operation, electric.

 

 

Q: God, can you explain to me in detail why?
The exit of the general pump is the first soft connection (shock absorber), followed by the check valve, and then the partition valve (such as butterfly valve, gate valve, cut-off valve, etc.), this is not the final answer.The question is interesting, and no corresponding information has been found in the relevant standards. We have also discussed the related issues, but differences of opinion is relatively large, the advantages of 1, first installed check valve installed after the valve or butterfly valve, check valve, can be protected, especially in a parallel pump, when the pump does not start, another pump starts when the impact force is gate valve or butterfly valve bear, disadvantages: gate valve or check valve who will protect? There have been a case of butterfly valve is broken. 2, first installed gate valve or butterfly valve installed after the check valve, advantages: can protect the butterfly valve or gate valve, the impact on the check valve to bear. Disadvantages: check valve who will protect, check valve by pressure difference switch, if the high pressure high pressure pipe, pump, if the flow is not stable, so check valve will repeatedly switch, will affect the check valve life. Personal opinion: check valve, check valve performance now have changed, many are using the slow closing check valve, so the impact force is two aspects to bear, because exports are not fully open the valve or butterfly valve, so you can put in check after the gate valve or butterfly valve valve. If not the slow closing check valve installed in the valve or the best after the butterfly.
Q: How can the check in the faucet prevent water from flowing backwards?
Not to prevent backflow, is able to quickly shut the water, for triple bathtub, can effectively stop the conversion between the bath and small shower water, there is a spring, when the water pressure will be water, a small amount of Water Leakage was shut up
Q: The role of the clip lift check valve
The check valve of the lift check valve is located on the valve seat sealing surface of the valve body. In addition to this valve disc is free to lift, like the rest of the cut-off valve, the fluid pressure valve from the valve seat sealing surface lift, medium return led down to the valve seat, and cut off the flow. Depending on the service conditions, the disc can be of all metal construction or in the form of a rubber pad or rubber ring on the valve frame. The same as the cut-off valve, lift check valve fluid through the channel is narrow, so the check valve by lifting the pressure drop than the swing check valve a little bigger, and swing check valve flow restrictions very little.
Q: What is the function of the stop valve and check valve installed on the water supply pipe?
The cut-off valve is a common valves, can also be used for throttling, mainly used to connect or disconnect the line of medium, generally not for regulating flows.
Q: What are the ten major brands of copper check valves?
I knew that:1, Amico2, Jie Kelong3 crown4, good day5, KITZ
Q: How can the check valve be distinguished from the cut-off valve?
1. check valve is called one-way valve, the role is to prevent fluid flow, can not be adjusted, can not be closed. 7, Y%, s) C, N, L., Q3, U6, J&, E9, R2., the cut-off valve can be used to regulate flow, can be closed, can be closed.
Q: Our unit pump outlet check valve installed in the vertical pipe, the use of the valve to stop the valve is more serious impact, is not installed, the valve should be how to install it?
Check valve is to withstand the impact of water hammer, you installed no problem.
Q: See English design drawings, found the check valve to a lot of good variety, do not know how to translate, please come and see God, and generous with your criticism.CHECK VALVE I search on the Internet, that is, the meaning of the check valve, but so many kinds, really do not know what it means, not only did not see, never heard of.CHECK VALVE - ANGLECHECK VALVE - ANGLE STOPCHECK VALVE - ANTI WHIPCHECK VALVE - STOPCHECK VALVECHECK VALVE - TILTING DISKCHECK VALVE - WAFERCHECK VALVE - Y STOPHigh reward oh, good answer, I will give you a big additional scores drop, huh, worried about kazakhstan. StopPlease make a explanation according to my offer English name, online copy paste do not explain visual satisfaction, I will give you an additional 20~100.Starbooks | browse 5128
This is more challengingI think these are all check valves, but the designer notes the structural features of the check valve itself to make it easy to distinguish.CHECK VALVE - ANGLE, if translated as "angle valve" must be wrong, but in the back of the check valve with an angle, will not be the valve is not an ordinary check valve, but the right angle structure of the check valve? Pure speculation. Right angle check valve.CHECK VALVE - ANGLE STOP ibid., the check valve of the right angle structure, mainly acts as a cut-off. Right angle stop valve.CHECK VALVE - ANTI WHIP physics, there is a professional interpretation, (anti whip device) pipe anti swing device, I guess there should be the meaning of anti shock, it is also one of the role of one-way valve. Here I translated as anti shock valve.The CHECK VALVE - STOP is different from the ANGLE STOP, and the ordinary structure is interpreted as a stop valve here.CHECK VALVE check valveCHECK VALVE - TILTING DISK tilting disc valve, this should be indicated on the special check valve structure, inside the JBT308, check valve structure with the valve structure, this should be inside the swing valve a.CHECK VALVE - WAFER flat plate check valve.The CHECK VALVE - Y STOP Y check valve is also a structural form. This does not understand, it translates into Y stop valve.
Q: How to install fire fighting pipe and flue fire check valve?
1, vertical transport, the flue should take protective measures, and must be two lifting.2. Locate the center line of the flue position. In the reserved hole, draw down four vertical central lines from the roof, and draw 2 orthogonal central lines on the floor plane.3, the flue to the scene, the first flue hanging to the roof, surrounded by the center line of pop in the flue, and the flue of the reserved hole slowly down the electric hoist, from top to bottom layer installed flue in place, the center line correction. The center line of the flue and the center line of the reserved hole should be less than 1cm, the deviation of the centerline of the upper and lower flue is not greater than 1cm, and each flue must be guaranteed vertically and vertically.
Q: Is the tank stop valve a non-return valve or a check valve?
Check valve is a one-way valve, automatically prevent reverse flow of fluid, no knob, can not be artificial blocking forward flow.
Yue,located in Ducun Industrial Park, Linhu Town, Wuzhong District, Suzhou, mainly produces valves. Our company is equipped with one scale automatic static coating line, two assembly testing lines, many sets of semi-automatic assembly testing equipment as well as processing equipment such as 5m,3m and 2m vertical lathes, 4m and 2m milling machines and boring machines.

1. Manufacturer Overview

Location Suzhou, China
Year Established 2000
Annual Output Value Above US$ 3 Million
Main Markets West Europe, South Africa, the Middle Eas
Company Certifications ISO 9001:2008

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port Shanghai
Export Percentage 40%
No.of Employees in Trade Department 500 People
Language Spoken: English; Chinese; Spain; Alabic
b) Factory Information
Factory Size: Above 18,000 square meters
No. of Production Lines Above 4
Contract Manufacturing OEM Service Offered; Design Service Offered
Product Price Range Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords