submersible motor pump Amarex KRT INDUSTRY H, C1, C2

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 pc
Supply Capability:
1 pc/month
Inquire Now Customer Service

Contact us by

(1) WeChat
(2) Whatsapp: +8617190086776

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

 

Design
Vertical, single-stage submersible motor pump made of wear-resistant                                                         industrial materials in close-coupled design, various impeller types,                                                           for wet or dry installation, stationary and transportable version. Design to ATEX.                                            
Applications
Handling of all types of abrasive or aggressive waste water in water and                                                     waste water engineering as well as industry, especially untreated sewage                                                        containing long fibres and solid substances, fluids containing gas /                                                            air, as well as raw, activated and digested sludge; sea water desalination.

 

Overview of technical data

Type of impeller                                                                         Open; Multi-vane impeller;Radial;Closed;Free flow impeller                    
Type of installation                                                                         Close- coupled                    
Maximum drive rating                                                                         200                         kW                    
Impeller material (EN standard)                                                                         JN 3029; 1.4517                    
Type of bearing                                                                         Rolling element bearings                    
Drive frequency                                                                         50 Hz / 60 Hz                    
Maximum speed of rotation                                                                         3. 500                         1/min                    
Maximum flow rate                                                                         2. 400                         m³/h                    
Maximum discharge-side pressure                                                                         10                         bar                    
Casing material (EN standard)                                                                         1. 4517;JN 3029                    
No. of impeller entries                                                                         Single entry                    
Casing material                                                                         White cast iron; Cast duplex steel                    
Suction characteristics                                                                         Non- priming                    
Drive voltage                                                                         Low voltage                    
eClass assignment                                                                         36410103; 36410101                    
Pump set location                                                                         Wet well                    
Explosion protection                                                                         ATEX II 2 G T3; ATEX II 2 G T4                    
Max. permissible fluid temperature                                                                         60                         °C                    
Free passage                                                                         120                         mm                    
Main applications                                                                         Water; Oil / Gas;Energy;Industry and process engineering;Mining / Dredges;Waste water / sewage                    
Type of installation                                                                         Stationary; Transportable                    
Type of casing                                                                         Volute casing                    
Type of connection                                                                         Flange                    
Type of lubrication                                                                         Oil lubrication                    
Type of drive                                                                         Electric motor                    
Installation position                                                                         Vertical                    
Shaft material (EN standard)                                                                         1. 4462;C45+N                    
Type of coupling                                                                         None                    
Shaft seal type                                                                         Mechanical seal                    
Drive                                                                         Electric motor                    
Maximum head                                                                         100, 00                         m                    
Maximum rated pressure (discharge)                                                                         PN 16                    
Nozzle position                                                                         End suction                    
Casing partition                                                                         Radially split                    
Connection to power supply                                                                         < 690 V, 3~

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is a positive displacement pump? He Weizheng displacement?
The principle and structure of positive displacement pumps are similar to those of hydraulic motors. Positive displacement is the pump outward to provide flow and pressure, that is, conventional pumps. A negative displacement pump is a hydraulic motor that rotates by external pressure and flow.
Q:What is the difference between centrifugal pump and positive displacement pump?
Positive displacement pump is the volume pump, this type of pump is to rely on changes in volume to compress fluid work, including: diaphragm pumps, gear pumps, screw pumps, etc.;
Q:Because the water pressure of the booster pump is not enough, it can not work automatically. It can only be operated by hand. It is inconvenient to use.
One possibility is the automatic type household booster pump used for a period of time, automatic failure phenomenon, it is mainly stainless steel and other metal products in pipes, long-term precipitation to shut off the power supply after unloading, unscrew the top screw, remove the plastic sheet to be cleaned, and then, according to the original reset, the normal debugging. Can be re used. But that's not why if your booster pump isn't working properly all the time.
Q:Hydraulic pump displacement refers to the pump shaft what?
Displacement of the hydraulic pump refers to the axis of each turn, the volume discharged, called displacement, the unit is ml (ML),
Q:Pneumatic diaphragm pump compressed air pressure is 4 kg, the discharge pressure is how big?
Generally slightly lower than 0.4MPa, Zai 0.35Mpa or so, if the outlet is blocked, the outlet pressure will equal 0.4MPa
Q:How can the submersible pump level meter be connected?
The company actively introduce international advanced production equipment and production technology, with its strong technical force, perfect equipment conditions and rich manufacturing practice, constantly development and improvement of pump products, according to the needs of users of innovative products, stable performance, excellent quality, many products export part countries and regions
Q:Double floor sewage pump circuit diagram of a small problem
Question 4 when you need backup, you need to switch the SA switch, but where you want it. For example, when the 1# pump is running and does not reach the high water level, the 2# pump will not operate. If SA is placed in the left position, 21 and 22 are connected, and the KT is electrically delayed, and the KAB action causes the 2# pump to function. After the KAB operation, the KT will be disconnected, restored to the ready state, and also convenient for KT to restart the power on time, and also avoid the time relay to work on a long-term basis.
Q:Difference between pump and compressor
In the spiral case, the liquid slows down due to the gradual enlargement of the flow passage, and the part of kinetic energy is converted to static pressure, and finally flows into the exhaust pipe at higher pressure and is sent to the required place. When the liquid flows from the center of the impeller to the outer edge, a vacuum is formed at the center of the impeller. As the pressure at the upper level of the tank is greater than the pressure at the pump inlet, the liquid is continuously pressed into the impeller. Visible, as long as the impeller continues to rotate, the liquid will continue to be inhaled and discharged.The working principle of the linear pump is different from that of any other pump. It adopts the principle of magnetic suspension and the hydraulic structure of the spiral ring to realize liquid propulsion, that is, to cancel the shaft, to cancel the shaft connection, and to cancel the sealing structure of the shaft. After starting, the electric current is transformed into a magnetic field, and the magnetic field force drives the spiral ring to move, namely, the spiral ring promotes the liquid advance.Compressor (compressor), a driven fluid machine that promotes low-pressure gas as a high pressure gas, is the heart of a refrigeration system. It is of low temperature and low pressure refrigerant gas suction pipe from the suction, through the operation of the motor drives the piston to compress it after high temperature and high pressure refrigerant gas discharge pipe to the exhaust, to provide power for the refrigeration cycle, so as to realize the compression and condensation (exothermic), expansion and evaporation (endothermic) refrigeration cycle.
Q:Roots pump and dry pumpRecently, the work involved in the vacuum pump, do not understand this, is a ads602 vacuum pump
Here the roots pump and dry pump must be used, because the roots pump is not used alone, and must be a stage vacuum pump (pre vacuum pump can be dry pump, water ring vacuum pump and rotary vane vacuum pump can be, you here with dry pump series)
Q:What does "anti pump" mean in pump operation?
The working process of the main oil cylinder pushing back and forth against the pump when the S valve (C valve or valve or gate valve skirt) reverse swing, so the piston suction concrete cylinder is in the ash conveying pipe is exactly opposite is the pump suction pump (hopper is concrete and push into the hopper, the desizing)

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range