• Stainless Steel Centrifugal Booster Water Pump System 1
  • Stainless Steel Centrifugal Booster Water Pump System 2
  • Stainless Steel Centrifugal Booster Water Pump System 3
Stainless Steel Centrifugal Booster Water Pump

Stainless Steel Centrifugal Booster Water Pump

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

Product Description:

1. Performance for CDL Series Designed Stainless Steel Vertical Multistage Pump:

Flow Range:1-200m3/h

Head Range:11-200m

Power Range:0.37-110KW

Temperature:-20ºC-120ºC

Material:Stainless Steel 304,316

Work Pressure:<1.6mpa< span="">

2. Introduction of CDL Series Designed Stainless Steel Vertical Multistage Pump:
Non self-priming type vertical multistage centrifugal pump, the motor is directly connected with the pump through shaft couplings, impeller guide vane is made of stamping stainless steel plate or precision casting stainless steel, smooth surface , hydraulic flow loss is small, and easily for cleaning, is very favorable for conveying pure medium. Pump inlet and outlet in a straight line(can be equipped with IEC or NEMA motor). 

3. Operating Conditions for CDL Series Designed Stainless Steel Vertical Multistage Pump:
Thin, clean, non inflammable and explosive liquid not containing solids or fiber. 
The liquid temperature: normal temperature type - 15 ºC to 70 ºC hot water type to + 120 ºC 
Environmental temperature: highest + 40 ºC 
Height: highest 1000m 

4. Motor Introduction of CDL Series Designed Stainless Steel Vertical Multistage Pump:
Motor is fully enclosed, air-cooled type 2 pole standard motors. 
Protection grade: IP55 
Insulation grade: F 
Standard voltage: 1Ph 220-230/240V 
3Ph 200-220/346-380V 
3Ph 220-240/380-415V 
3Ph 380-415V 

5. Typical Applications for CDL Series Designed Stainless Steel Vertical Multistage Pump:
Water supply: water filtration and conveying, waterworks water supply, pipe pressurization, high-rise building pressurization. 
Industrial pressurization: process water system, cleaning system, high pressure flushing system, fire control system. 
Industrial liquid transportation: cooling and air conditioning system, the boiler feed water and condensation system, machine tool accessory, acid and alkali. 
Water treatment: ultrafiltration system, reverse osmosis system, distillation system, separator. 
Irrigation: farm irrigation, sprinkler, drip.

 

6. FAQ for CNBM Pumps

1>  Can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

2> Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

3>  How long is your warranty?

Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice.

4> Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price. 5> Do you have self-priming pumps?

Yes, our product portfolio also includes two ranges of self-priming pumps: self-priming electric pumps and self-priming side channel pumps.

6> Is it really necessary to fit a bleed valve for the boxes?

It is always best to have a bleed valve as the gas produced by the fermenting sewage is potentially hazardous.



CDL Series Designed Stainless Steel Vertical Multistage Centrifugal Pumps

CDL Series Designed Stainless Steel Vertical Multistage Centrifugal Pumps



 

Q:Piston filling and peristaltic pump filling which precision is high?
If the unit area is large, the accuracy of the plunger is certainly not high. The peristaltic pump is used by means of extrusion roller extrusion pump to promote the solution, this also depends on the unit cross section size, the same motor accuracy is very important.
Q:Fire pump and shower pump flow head selection, high resolution.
2, the volume is greater than 10000 is less than 25000, the minimum water consumption of indoor fire hydrant is 15L/s
Q:Hydraulic pump displacement refers to the pump shaft what?
You can see the sign of your hydraulic pump. There will be a displacement **ml/r in the sign of the hydraulic pump (r stands for every turn, ML is milliliter)
Q:How to install, operate and maintain the pipeline booster pump?
The motor coil is provided with a safety protector, and when the pump is out of order or the water is not pumped, the motor can automatically break down when the temperature of the motor exceeds the prescribed value, and the motor can automatically resume operation after the temperature rise of the motor is decreased. The booster pump motor is a capacitor running type motor. When the pump leaves the factory, the rotation direction has been adjusted. If you need to replace the capacitor or re connect, press the arrow direction on the pump body to mark the connection. To ensure safety, use the three - core safety socket with ground wire.
Q:What is the function of a submersible pump?Do you have any knowledge about submersible pumps?.
The working principle of submersible pumpBefore the pump is opened, the suction pipe and pump must be filled with liquid. Open the pump, the impeller rotating speed, which leaves the liquid together with the rotation under the action of centrifugal force, the left outside impeller injection, injection of the liquid in the pump shell gradually slow the spread of indoor speed, the pressure gradually increased, and then from the pump outlet, the outflow discharge tube. At this time, in the leaves at the center of the vacuum area of low pressure liquid was thrown to the surrounding formation there is no air and no liquid, liquid pool at the surface of the liquid under the action of atmospheric pressure, through the suction pipe into the pump, the liquid is continuously pumped up from the liquid pool is also continuously from the outflow discharge tube.
Q:What are the internal losses in centrifugal pumps? How did they come about?
Hydraulic loss: the loss of water by friction, eddy, impact, etc in a flow;
Q:Fire hydrant pump button, under what circumstances do not need to install?
General high voltage system, when normal, use small pump steady pressure.Fire hydrant button lifting pump is one of the multiple pumping methods, and it is an important link of reliable operation of the system.
Q:What is the main difference between SK water ring vacuum pump and 2BV water ring vacuum pump?
SK vacuum pump is a single-stage water ring vacuum pump, vacuum pump and motor separation, coupled with couplings, vacuum relatively low.
Q:What are the problems that should be paid attention to when using vacuum pumps?
(8) in the process of running the pump, the bearing temperature shall not exceed the ambient temperature 35C, and the maximum temperature shall not exceed 80C.(9) if the abnormal sound of the vacuum pump is found, the reason should be stopped immediately.(10) vacuum pump to stop using, first shut down valve, pressure gauge, and then stop the motor. (11) vacuum pump in the first month of work, 100 hours after the replacement of lubricating oil, oil every 500 hours after the change.(12) adjust packing gland regularly to ensure the normal condition of drip in packing room. (13) regular inspection of shaft sleeve wear, larger wear should be replaced in good time.
Q:How to maintain and repair the booster pump of pipeline pump?
Installation and use1. use rubber washer and bolt to connect the pump flange at both ends and the pipe flange. In order to use and maintenance convenience, in the pump inlet and outlet pipelines should be installed with a regulating valve.2. open the inlet control valve, so that water into the pump, in order to keep the cavity filled with liquid (otherwise it will damage the seal), close the outlet valve.3. turn on the power and make sure the correct turn.4. make sure the pump starts and runs after turning.5. adjust the opening of the outlet valve so that the pump runs near the design point, depending on the rated flow and lift of the pump. [for this reason, it is better to place a pressure gauge near the outlet flange). Note: this pump is strictly prohibited to run without water, so as not to damage the seal.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords