1.Single conductor Type UD Cable- Aluminum Conductor

1.1 Applications
Directly buried or installed in ducts for 600 volt secondary distribution.
1.2 Standards
Secondary UD single conductor 600V cable meets or exceeds the following ASTM specifications.

  B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
  B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
  B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
  B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
  Secondary UD single conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
  "USE-2" per UL 854 available upon request.
1.3 Options
  Cable in Duct (CIC)
  Abrasion Resistant
Ampacity
90oC conductor temperature, 20oC ambient, RHO factor 90, 100% load factor for three conductor triplexed, 3 phase operation. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
1.4 Specification

Item Size AWG or Stranding Insulation Outside Dia. Weight Per KM
MCM mm mm Kg
Princeton 6 7/W 1.524 7.57 66.96
Mercer 4 7/W 1.524 8.76 95.23
Clemson 2 7/W 1.524 10.24 138.38
Kenyon 1 19/W 2.032 13.26 220.22
Harvard 1/0 19/W 2.032 12.24 181.54
Yale 2/0 19/W 2.032 14.38 266.35
Tufts 3/0 19/W 2.032 15.65 322.90
Beloit 4/0 19/W 2.032 17.07 394.32
Hofstra 250 37/W 2.413 19.00 471.70
Gonzaga 300 37/W 2.413 20.35 552.05
Rutgers 350 37/W 2.413 21.62 629.42
Emory 500 37/W 2.413 24.87 861.55
Duke 600 61/W 2.794 27.58 1043.09
Furman 700 61/W 2.794 29.34 1196.35
Sewanee 750 61/W 2.794 30.18 1272.24
Fordham 1000 61/W 2.794 33.96 1650.19

 
2.Duplex Conductor Type URD Cable-Aluminum Conductor2.1 Applications
Directly buried or installed in ducts for 600 volt secondary distribution.
2.2 Standards
Secondary UD duplex conductor 600V cable meets or exceeds the following ASTM specifications.
  B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
  B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
  B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
  B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
  Secondary UD duplex conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
  "USE-2" per UL 854 available upon request.
2.3 Options
  Cable in Duct
  Abrasion Resistant
Ampacity
90oC conductor temperature, 20oC ambient, RHO 90, 100% load factor. All yellow extruded stripe cable is XLP insulation. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
2.4 Specification

Item Phase Conductor size Phase Conductor Stranding Phase Conductor Insulation Thickness Neutral Size Neutral Stranding Neutral Insulation Thickness Single Phase Conductor Single Phase Conductor Weight Per Km
AWG mm AWG mm mm mm Kg
Bard 8 7/w 1.524 8 7/w 1.524 6.65 13.31 113.09
Claflin 6 7/w 1.524 6 7/w 1.524 7.59 15.14 135.41
Delgado 4 7/w 1.524 4 7/w 1.524 8.76 17.53 191.95
Everett 2 7/w 1.524 2 7/w 1.524 10.24 20.47 281.23

3.Triplex Conductor Type URD Cable- Aluminum Conductor
3.1 Applications
Directly buried or installed inducts for 600 volt secondary distribution.
3.2 Standards
Secondary UD triplex conductor 600V cable meets or exceeds the following ASTM specifications.
  B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
  B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
  B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
  B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
  Secondary UD triplex conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
  "USE-2" per UL 854 available upon request.
3.3 Options
  Cable in Duct (CIC)
  Abrasion Resistant
Ampacity
90oC conductor temperature, 20oC ambient, RHO 50, 100% load factor for three conductor triplex with neutral carrying only unbalanced load. Technical data for cable with solid black neutral is identical to yellow extruded stripe data. All yellow extruded stripe cable is XLP insulation. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
3.4 Specification

Item Phase Conductor size Phase Conductor Stranding Phase Conductor Insulation Thickness Neutral Size Neutral Stranding Neutral Insulation Thickness Single Phase Conductor Single Phase Conductor Weight Per Km
AWG mm AWG mm mm mm Kg
Erskine 6 7/w 1.524 6 7/w 1.524 7.59 16.41 212.78
Vassar 4 7/w 1.524 4 7/w 1.524 8.76 19.15 302.06
Stephens 2 7/w 1.524 4 7/w 1.524 10.24 21.39 392.83
Ramapo 2 7/w 1.524 2 7/w 1.524 10.24 22.20 437.47
Brenau 1/0 19/w 2.032 2 7/w 1.524 13.26 27.03 607.10
Bergen 1/0 19/w 2.032 1/0 19/w 2.032 13.26 28.78 691.92
Converse 2/0 19/w 2.032 1 19/w 2.032 14.38 29.82 746.98
Hunter 2/0 19/w 2.032 2/0 19/w 2.032 14.38 31.19 833.28
Hollins 3/0 19/w 2.032 1/0 19/w 2.032 15.65 32.41 901.73
Rockland 3/0 19/w 2.032 3/0 19/w 2.032 15.65 33.93 1008.86
Sweetbriar 4/0 19/w 2.032 2/0 19/w 2.032 17.07 35.28 1099.63
Monmouth 4/0 19/w 2.032 4/0 19/w 2.032 17.07 37.01 1232.06
Pratt 250 37/w 2.413 3/0 19/w 2.032 19.00 39.07 1328.78
Wesleyan 350 37/w 2.413 4/0 19/w 2.032 21.62 44.09 1735.01
Holyoke 500 37/w 2.413 300 37/w 2.413 24.87 51.00 2391.22
Rider 500 37/w 2.413 350 37/w 2.413 24.87 51.69 2474.54
Fairfield 750 61/w 2.794 500 37/w 2.413 30.1752 52.98 3428.35

4.Quadruplex Conductor Type URD Cable & Mobile Home Feeder
4.1 Applications
Directly buried or installed in ducts for 600 volt secondary distribution.
4.2 Standards
Secondary UD quadruplex conductor 600V cable meets or exceeds the following ASTM specifications.
  B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
  B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
  B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
  B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
  Secondary UD quadruplex conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
  "USE-2" per UL 854 available upon request.
4.3 Options
  Cable in Duct (CIC)
  Abrasion Resistant
Ampacity
To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
4.4 Specification

Item Phase Conductor size Phase Conductor Stranding Phase Conductor Insulation Thickness Neutral Size Neutral Stranding Neutral Insulation Thickness Single Phase Conductor Single Phase Conductor Weight Per Km
AWG mm AWG mm mm mm Kg
Tulsa 4 7 1.524 4 4 1.524 8.76 21.16 383.90
Dyke 2 7 1.524 4 4 1.524 10.24 23.83 514.85
Wittenberg 2 7 1.524 2 2 1.524 10.24 24.71 558.00
Notre Dame 1/0 19 2.032 2 2 1.524 13.26 30.18 805.01
Purdue 1/0 19 2.032 1/0 1/0 2.032 13.26 32.00 886.85
Syracuse 2/0 19 2.032 1 1 2.032 14.38 33.43 988.03
Lafayette 2/0 19 2.032 2/0 2/0 2.032 14.38 34.72 1071.36
Swarthmore 3/0 19 2.032 1/0 1/0 2.032 15.65 36.32 1197.84
Davidson 3/0 19 2.032 3/0 3/0 2.032 15.65 37.77 1300.51
Wake Forest 4/0 19 2.032 2/0 2/0 2.032 17.07 39.62 1456.75
Earlham 4/0 19 2.032 4/0 4/0 2.032 17.07 41.22 1586.21
Slippery Rock 350 37 2.413 4/0 4/0 2.032 21.62 49.40 2297.47
Wofford 500 37 2.413 350 350 2.413 21.62 59.64 3234.91
Windham 750 61 2.794 500 500 2.413 24.87 72.39 3782.50

 
 
 


Q: a usb cable has 5 volts and 2.5 watts. so can it still power if it has 5 volts and 1.5 watts
Uh...YES! The voltage matches and the current will be regulated by the resistance of the device being powered. It will work fine.
Q: I've lost the power cable (and other regular connection cables) for my Dell computer but have some from another computer (but don't know the make of them). This might be a stupid question but..can I use these for my Dell computer or do they need to be Dell cables?
Hi - yes, so long as the cable does not contain a power pack (DC power supply) such as on laptop computers... If so you need to check the DC voltage/power rating on the power pack. But for normal desktop computers- any cable will do. Cheers, Kane.
Q: do i need to buy the cable that says specifically for ground? or can i just use my left over wiring from the power cable to connect in the ground? is there a difference between the two cables?
i would just use the left over power wire for the ground cause i have a 1000 watt amp and i used the power wire and it work perfectly .
Q: when you install a power cable you usually route it through the door seal and under the carpet. If there are existing speaker wires that go to your rear speakers, will the power cable create an interference?
No, just run it through the middle of your car, not through the sides. My runs right under the cup holder area under the seats and right to the back. You cant even see it lol, my pros did a great job putting it in
Q: Also i want to add more power cables to power my hardrives WHAT SHOULD I BUY !!?
You buy internal SATA cables from a store like Micro Center. You can also buy adapters that plug into your hard drive power supply connectors and then your SATA drives. But you could also buy a new power supply that has multiple SATA power connectors
Q: I have a cam camcorder battery charger power cable and I want to use it as a ps1 power cable. Is It possible. The both look the same.
If your talking about the end that looks like an 8 then yes it should work fine. That is a unerversual power cable. However if your PS1 has a small single round hole, i would be careful. Make sure the power is the same, you can check this by looking on the bottom, it should tell you what the conversion is, for ex: like 120v to 6v. Make sure your not throwing to much poser into your ps1.
Q: While DISCONNECTED from the amp, I accidentally touched the power cable with the ground cable. Sparks went flying and I smelt a funny odor. Since then, when I go to turn on my radio, my amp only lights up for a second and then looses power. Unfortunately, I feel I've fried my ground wire (upon close inspection, the power/battery cables fuse is still good along with amp signal wire and RCA's) My question is simply this: When replacing my ground wire, can I use left over power/battery cable? I have about 3 feet left over from the install. Thank you for your help!!
Theoretically, yes. I would make sure I was the only one using the system or messing around with it just to make sure no one mistakes it for a power cord. Also, wrapping each end with black electrical tape will work to identify it is a ground cable, being that black is universally known for ground. If you feel like wasting good money, wrap the whole cord with black electrical tape. Also, keep it away from professional installers so they do not mix it up, or just let them know it is a ground. Just keep it short enough so that it actually works as a ground (most manuals recommend less than 3 feet)
Q: Hey I just recently bought a Randal RB200X bass amplifier combo but it came with no cables or power chords or anything. Can someone please tell me what I need to buy in terms of cables to turn this amp on? I am clueless and am really desperate! Please help.
Abes okorder ... All you need is a standard guitar cable to connect the bass to the amp.
Q: Is the ribbon cable the data cable and the wires the power cables?
You are correct. Power cables will always have 4 or more separated wires going into a plug. Data cables have all of their internal wires inside a single sheath.
Q: what would happen if i used a 10 guage power cable on a 2400 watt amp, would it blow the fuse of would the amp just creat less power? thnx
10 gauge should only be used to go from amp to speakers because its such a short distance. according to rockford fosgate you will lose 1157 watts of your possible 2400 watts possible. in short it would cause close to 50% less power and you would probably fry your power cable. and if you go above 2,000 watts it is actually unsafe to run smaller than 1/0 gauge power wire.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords