• Plastic Pump For Swimming Pool System 1
Plastic Pump For Swimming Pool

Plastic Pump For Swimming Pool

Ref Price:
get latest price
Loading Port:
Ningbo
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
35000台 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

1.PPO impeller
2.coper wire,brass winding
3.plastic pump body
4.CE,ROHs,ISO9001 approved
5.1 year warranty

1'' 6m3/h liter plastic pump

♦Application

It is used for water circulation in all kinds of small domestic swimming pools. Slightlydirty water with solids in supension can be perfectly filtered.

♦PUMP

Plastic pump body

AISI 304 shaft

Max.liquid temperature:35°C

Max. suction:3.5m

♦MOTOR

Motor with copper winding

Build-in thermal protector for single phase motor

Insulation class:B

Protection class:IP68

♦FEATURES

1. CE, GS certificate

2. 100% copper wire, automatic wiring

3. Cold-rolled silicon steel sheet, with high-speed punching, improve the efficiency and

precision.

4. CNC precision automatic lathe for smoother shaft.

5. Strict tests include water test, outgas test and performance test, ect.

6. Anti-rust treatment castings and electrophoresis.

7. 23-year experience, 1 year warranty.

♦MIAN MARKET

America,Russia,Australia,Turkey,Egypt,Gernamy,Bangladesh,Thailand,Srilanka,Pakistan,Iran,Lebanon,Iraq,Panama,Colombia,Afghansistan,DubaiHongKong,Vietnam,ect.

♦OUR ADVANTAGE

1.24 years of water pump OEM production experience.

2.Large quantity, more discount.

3.Suffiencient stock and fast shipping.

4.High quality and excellent after sale service.

Q:What are the main performance parameters of the pump?
RPM revolutions per minute. In N, the unit is R / minThe power delivered by the shaft power prime mover to the pump shaft. In P, the unit is kW.The ratio of useful power to shaft power of an efficient pump. With ETA said. It is an indicator of the degree of perfection of the pump in terms of hydraulic power
Q:There are second cutting, third cutting, why three times?
There are 2 situations, first, for example, a XXXX-160 type pump head 32, flow 100, motor 15kW, according to the model we need to cut a become head 28, flow rate of 88, this time, in addition to cutting the impeller, the pump or the original pump motor, became 11kW this is, re designed a new model, namely XXXX-160A, but most structural components did not change. In the same way, we want to design a XXXX-160B that makes the head 24 and the flow rate 80, then we just need to cut the impeller again and match the smaller (7.5kW) motor (the motor bracket needs to be redesigned). In general, multiple cutting impellers are designed to expand and enrich the model. Second, the actual use, if you think the flow head is too large, but also can be cut to make it smaller to adapt to practical applications. But the 2 and 3 cuts you ask are the first.
Q:Shielding pump is the main drawback of electricity? How much does it cost more than an ordinary centrifugal pump? Is there any noise in the running of the canned pump? How much is it lower than the noise of the common centrifugal pump?
The ordinary centrifugal pump is driven by coupling the pump impeller shaft is connected with the motor shaft, the impeller and the motor rotates while working and shielding pump is a kind of non seal pumps, pump and motor is sealed in a medium filled by pumping the pressure vessel, the pressure vessel only static seal and, by a group of wires to provide a rotating magnetic field and rotor drive. The structure eliminates the rotary shaft sealing device of the traditional centrifugal pump, so the utility model can be completely free from leakage.
Q:What is the function of the heating pump system for the water pump design?
As the feed water temperature is higher, before starting, if not enough to warm the pump, the pump body temperature is uneven, there is a hot, cool phenomenon. The upper part is inflated and the lower part is inflated"
Q:Why can't the inlet of centrifugal pump be negative pressure?
Therefore, the centrifugal pump inlet pressure can be negative, and negative number, should be used to pump cavitation margin and liquid saturated steam pressure parameters to specific calculation. Sometimes, the liquid saturated steam conveying pressure is very high, such as the 9 m water column, then the minimum pressure of the pump inlet should be equal to 4+9=13 meters, the atmospheric pressure is higher than 3 meters, not only for negative pressure, even higher than the atmospheric pressure to work properly.
Q:Please give me professionals to calculate, the cylinder bore is 100 and the rate of 20m/s, the leakage can be ignored, but to the large flow pump!
1. rpmOperating speed is the actual rotation speed of a pump (or motor) at work.Rated speed is the maximum speed that can operate normally for a long time under rated pressure. If the pump exceeds the rated speed, the work will cause insufficient oil absorption, vibration and noise, the parts will suffer cavitation damage, life expectancy.Minimum steady speed is the minimum speed allowed for normal motor operation. At this speed, the motor does not appear crawling phenomenon.
Q:What's the difference between a concrete pump and a concrete pump truck?
Concrete conveyor pump height and distance can reach hundreds of meters, which is far more than pumping vehicles, but it needs cloth tube, not flexible enough. Less investment.Pump car use more flexible, higher investment.
Q:Variable flow pumps are variable pumps
Variable input speed, the pump out of the flow is variable, it can not be said that it is variable pump.In a word。 A variable pump is a variable displacement pump.
Q:What is the pumping property of concrete?
Under a certain pump pressure, the farther or higher the concrete can deliver, the lower the probability of clogging, the better the concrete pumping performance.
Q:What is the difference between centrifugal pump and positive displacement pump?
Positive displacement pump is the volume pump, this type of pump is to rely on changes in volume to compress fluid work, including: diaphragm pumps, gear pumps, screw pumps, etc.;

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches