• HPL/PVC Coated Wood Core Raised Access Floor System 1
  • HPL/PVC Coated Wood Core Raised Access Floor System 2
  • HPL/PVC Coated Wood Core Raised Access Floor System 3
HPL/PVC Coated Wood Core Raised Access Floor

HPL/PVC Coated Wood Core Raised Access Floor

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or L/C
Min Order Qty:
1500 PCS pc
Supply Capability:
50000PCS Per Month pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications of HPL/PVC Coated Wood Core Raised Access Floor
1. CE certificate
2. B2 fireproof
3. Antistatic tile,galvanized steel bottom panel
4. High density particle board,PVC/ABS edge trim, sound proof
5. High dimensional precision, strong loading ability and shockproof.
6. Adjustable height for pedestal , assembly agility, large wire, good exchangeability.
7. Outlet mating . Elegant appearance for paving wildly brand top tiles.
8. Light weight ,high loading capacity ,excellent raised flooring in 21th
9. Light weight ,convenient removing, saving

Structure of HPL/PVC Coated Wood Core Raised Access Floor
1.panel- 30/38mm thickness particle board ,PVC/ABS corvered four edges,steel/aluminium on the bottom plate ,wildly brand top tiles is HPL. 
2.Accessories -die casting steel structure pedestal plastic gasket on top ,height could be 70mm ---1500mm , with or without square tube stringer steady connect the system

 

Applications of HPL/PVC Coated Wood Core Raised Access Floor
Wide range of the application , all kinds of computerroom, network service engine room, control room, montoring cabin, top grade office

 

Type& Technology parameter of HPL/PVC Coated Wood Core Raised Access Floor

Type

International

Size(mm)

Fire

Performance

Concentrated load

Impact load

(N)

Ultimated load

(N)

Uniform

Load

(N/m2)

Rolling load(N)

LB

N

KG

10 times

100000

times

CM-2001

FS440

600x600x32

A

≥440

≥1960

≥200

≥295

≥5880

≥9272

1958

1566

CM-2002

FS662

600x600x40

A

≥662

≥2950

≥301

≥445

≥8850

≥1250

2946

2356

CM-2003

FS800

600x600x40

A

≥800

≥3350

≥363

≥536

≥11250

≥16100

3560

2670

Production of HPL/PVC Coated Wood Core Raised Access Floor

production of Raised Access Floor

Packing of HPL/PVC Coated Wood Core Raised Access Floor

packing of Raised Access Floor

Q: How to install anti-static floor
Step: 1, floor cleaning; 2, carefully check the surface flatness and perpendicularity of the walls, such as found not to meet the construction requirements, the departments concerned party; horizontal pull, the well floor mounting height with elastic ink line on the wall, ensure that the laying of the floor at the same level, the measuring chamber length, width, and appropriately select the laying reference position to reduce the cutting floor. the installation grid lines bracket the ground; to be mounted bracket is adjusted to the height of the same needs and the stent Ling Li and Gu pad pedicle cutting jig placed slightly bite into the ground of the cross grid lines; 3, with the screw secured to the frame beams, and with a spirit level n beams, perpendicular to each other and so that on the same plane ; with a suction plate is placed on the transom in the assembled floor: the square by four, if the size is less than the remaining wall length of the floor itself, the available methods for cutting floor fight Lee; 5, Edge; 6, clean up the site, completed; note 1, when the laying of the floor, with a bubble level leveling, the height adjustment bracket on the floor; 2, placing heavy apparatus at the room, the device should be in the base The lower plate installation bracket to prevent deformation of the floor; 3, when the floor needs to be cut or opening, the application opening in the corner drill hit Φ6mm-Φ8mm circular, veneer prevent breakage....
Q: What is the anti-static floor edge material
The edge of the edge of the plant with the material is not sturdy shield box Yong Valley fall Yan Kai Kai, there are all steel, there are alloys, PVC, etc., as long as the conductive, are in use, the price is low to the provincial cost of the principle, Good quality to use good materials, there are no side of the floor.
Q: All-steel ceramic anti-static floor. How can you open the hole? Used to take the line. What tools can I open the hole at once? Question added: .. both brick and brick but also ceramic tiles have not? To open the hole, what turned around? More
Network cable buried under the wall and then how to open the floor?
Q: The height of the static floor in the central control room is not required
Of course! The height is related to the material of the electrostatic floor
Q: Anti-static floor cracked how to do
Shoddy products directly exchange Huili has never been such a situation.
Q: Composite anti-static floor with an empty one square meter how much money
Now in the use of such anti-static floor is very small, the price is also expensive and also divided into different types of law for fear of forging ding kicking fist and quality, the highest to more than a thousand, the most expensive to three Hundreds of bars
Q: My clothes are silk, and nothing around, how to do it? Is it really effective to keep the body against the wall? I would like to solve the problem as soon as possible. Thank you. Question added: I am now in school, hands empty, how to do? More
Clothes tide, will be better
Q: We use the kind of ordinary soldering iron, there is no grounding line, the staff in the solder fool Shibao whispering child care when the child wearing a static electric ring parts will be tingling when not welding, ask how is the matter, how to solve? Thank you! More
It is not clear, we fool the bar ?o ?o child care utility unit useless electrostatic ring, electric iron temperature control on the line, grounding does not matter, if you are welding the sensitive components so the best or ground. The general parts of the use of electrostatic pad shop and the ground on it.
Q: Is the insulation floor and the anti - static floor the same thing?
Anti-static floor is insulated floor, insulated floor is not necessarily anti-static. If you have more questions, you can click on ID consultation.
Q: Is it necessary to set up a gas fire extinguisher and a detector under static floor?
Gas fire extinguishing device do not understand, look at.
Established in the 1980s is an enterprise specialized in producing and marketing the anti-static all-steel raised floors. It had been focusing on technical development and scientific management. It has a strong working team of research, production marketing and management.

1. Manufacturer Overview

Location Changzhou, China
Year Established 1991
Annual Output Value Above US$ 50 Million
Main Markets Mid East; Western Europe; North America; Oceania; Eastern Asia
Company Certifications ISO9001-2008

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port Shanghai
Export Percentage 100%
No.of Employees in Trade Department 30-50 People
Language Spoken: English; Chinese
b) Factory Information
Factory Size: 150,000 square meters
No. of Production Lines 5
Contract Manufacturing OEM Service Offered
Product Price Range Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords