• Raised Floor with HPL finish Steel flooring System 1
  • Raised Floor with HPL finish Steel flooring System 2
  • Raised Floor with HPL finish Steel flooring System 3
  • Raised Floor with HPL finish Steel flooring System 4
Raised Floor with HPL finish Steel flooring

Raised Floor with HPL finish Steel flooring

Ref Price:
get latest price
Loading Port:
Guangzhou
Payment Terms:
TT OR LC
Min Order Qty:
4000 g/m²
Supply Capability:
50000 g/m²/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

aised Floor with HPL finish Steel flooring

Model: HGD600

Dimension: 600×600×35/30(mm) 

 

This product is made of quality steel plate, which is stretched forming, point welded and plastic sprayed with bubble cement filler filled in its inner cavity. The fire-resistant decoration plates that can endure high temperature adhere to its surface with conductive chips embedded around it. The pedestals and cross beams are wholly plated with zinc and the height of pedestals is adjustable and can be self-locked.

TYPE Concentrated Load Impact Load Ultimated Load Uniform Load Rolling Load
 LB N KG N N N/ 10passes10000passes 
HGD600-Q  800 3550363 670 ≥9400 ≥14680 3560 2670
HGD600-B ≥1000 4450 453 670 ≥11970 ≥16900 4450 3560
 HGD600-Z ≥1250 5550567 670 ≥14360 ≥22240 5560 4450
 HGD600-CZ ≥1500 6660680 780 ≥17950  ≥26690 6670 5560


Features
  


Designed specially for computer room&clean room
Excellent rolling load & ultimate load performance
Light weight cementitious fill makes panels solid and quiet
Completely non-combustible
Black electrodeposition cathodic epoxy paint finish for life time protection
Class A flame spread and smoke development rating
Wide range of finishes available

 

Applicable Fields
Computer rooms, programmed control equipment rooms, electrical-controlled classrooms, places that have requirements of dust-proof and anti-static, and fields with aerial requirements.

 Pedestal and Stringer 

 

         

Installed Example 

 

HPL Colour Card 

 

8063

 

8117

 

8119

 

8132

 

8137

 

8138

 

8144

 

8156

 

8191

 

8192

 

8193

 

8194

 

8213

 

8311

 

8312

 


BEISIDE® computer, server, control room, and general office access floors is China fastest growing raised access-flooring manufacturer. HUIYA help design and create smarter buildings utilizing HUIYA's state of the art raised flooring systems to help organize your voice and data requirements. Create your intelligent building by using the access floor as an open-air plenum. With over 10 years of experience around the construction industry, HUIYA is committed to being part of the solution.


Businesses have responded quickly and dramatically to rapid technological changes over the last several years. Yet, building systems have been slow to accomodate these demands. Changes to office environments continue to be disruptive, slow and wasteful. Repairs to sensitive equipment and data remains unnecessarily high. Environmental efficiency and comfort is more important than ever. HUIYA's Raised Access Flooring systems eliminate the need for embedded wiring and provides instant access to wiring and cabling, allowing for quick and easy reconfiguration of your office space. HUIYA has the technology to address advances in electronic work flow, conservation and occupant comfort.


Why an Access Floor?


*     Construction programmes are reduced by at least two weeks per floor due to elimination of a sand cement screed.

*     As warm air rises, considerable cost savings are achieved by an underfloor air plenum delivering conditioned air exactly where it is needed - compared with the traditional uneconomic alternative of forcing conditioned air from the ceiling.

*      Maximum flexibility for the installation and reconfiguring of services to equipment and workstations a matter of hours.

*      In new construction the use of an access floor for total service distribution reduces the overall building height by about 13%. Or, for the same height, you can increase the number of floors. 

                                          


Q: Computer room anti - static floor of the room design standards
Activities under the floor of the space only to use the cable laying, the floor height of not less than 250mm. If used as air-conditioning static pressure box, the height of not less than 400mm
Q: Would you like to use anti-static flooring for room decoration?
Hello this is yes
Q: Selling and selling anti-static flooring which is easy
Easy to sell. Anti-static flooring for users after all, is a professional user, but also less
Q: How to drill holes in the engine room? Drill a good hole after drilling a good hole?
With ordinary drill bit on it, and then sell the hardware where the hardware sold
Q: Anti-static floor material classification
1, all-steel anti-static floor 2, clean room all-steel anti-static floor 3, protective-type anti-static floor 4, ceramic surface anti-static floor - metal composite activities floor 5, all steel anti-static ventilation plate 1, Anti-static ventilation board 2, aluminum grille plate 3, aluminum alloy blind plate 1, reinforced composite anti-static floor 2, anti-static ceramic steel composite flooring 1, straight pvc anti-static floor, permanent PVC anti-static floor 1, all steel 0A network floor
Q: Room design requirements anti-static floor standard height is how much
Activities under the floor of the space only to use the cable laying, the floor height of not less than 250mm intestinal puncture nucleus to do too fierce. If used as air-conditioning static pressure box, the height of not less than 400mm
Q: What is the difference between an anti-static floor and an anti-static floor?
1, the appearance of the edge of the anti-static flooring in the steel anti-static floor is more common, surrounded by a black conductive tape embedded in the protection of the bitter Huang Hong Puerong Guo bronze Gong expansion. And boundless anti-static flooring as the name suggests is no black strip around, after the installation of the floor between the joints more fine, the overall effect is better. 2, the installation of the edge of the anti-static floor because of the reasons for the black side of the installation of the ground on the flatness of the floor installation requirements are not too high. Unilateral anti-static floor because there is no black side of the ground, the flatness is poor or the installation is not in place are likely to lead to two pieces of the floor between the wrong seam, flatness of the poor situation, so the edge of the anti-static floor requirements for the ground leveling and workers to install the master The level of the requirements are higher than the side, the installation is difficult. 3, the latter part of the maintenance on the anti-static floor pavement is completed, in the latter part of the engine room line adjustment process, the need for special attention in the flip floor when the edge of the anti-static floor prone to edge of the situation, and no anti-static floor Black border also does not exist such a situation, but the boundless anti-static floor because there is no protection of the black side of the floor, when turning the floor, if not careful may lead to the edge of the floor veneer damaged.
Q: What is the overhead floor
There is room below the floor. Such as the floor of the stage, keel floor.
Q: How is the floor of the anti-static floor?
Anti-static floor, welded through copper mesh, and then grounded.
Q: Construction of weak and fire control room must do anti-static floor? Has there been any impact on future acceptance?
Construction of weak and fire control room must do anti-static floor? Has there been any impact on future acceptance?...

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords