Horizontal Booster Water Pump for Boiler Feed
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Horizontal Booster Water Pump for Boiler Feed
1.Structure of Horizontal Booster Water Pump for Boiler Feed
The high presuure boiler feed multistage water pump is a horizontal multistage centrifugal pump and suitable for transporting pure water,both ends of it are supported,the casing portion is a senctional form,it is connected and actuated by motor via a resilient clutch.From the driven direction,the pump rotated direction is clockwise.
2.Main Features of Horizontal Booster Water Pump for Boiler Feed
• High Effiency
•Low noise
•Long life, OEM and ODM are welcomed.
3.Horizontal Booster Water Pump for Boiler Feed Images
4.Horizontal Booster Water Pump for Boiler Feed Specification
Material |
Cast iron and as customer's request |
Temperature |
Less than 150°C |
Flow rate | 3.75-300m3/h |
Head | 75-1000m |
Medium temperature | 0 ~170°C |
Operation pressure | ≤40 bars |
5.FAQ
①What is the applications?
Power Station,Industry Water Supply
②How to guarantee the quality of the products?
We have established the international advanced quality management system,every link from raw material to final product we have strict quality test;We resolutely put an end to unqualified products flowing into the market. At the same time, we will provide necessary follow-up service assurance. Normally, We have 1 year warranty.
- Q:Is vane pump good or gear pump good?
- 1) the reversible design of gear pumps can also usually reverse, but reverse after the suction port change, and the pump safety valve does not work; leaf pump is generally not allowed to reverse. 3) the single acting vane pump can be designed to change the eccentric distance by moving the stator at the constant speed, so as to achieve the purpose of variable direction.
- Q:If the calculation of the required pump flow is 45, lift 110, and the actual pump flow 100, head 125, what will happen in operation? Can I use it properly?
- Centrifugal pumps are too big to measure.There is a reason why the centrifugal pump does not measure up:The pump inlet pipe blockage, leakage.The pump inlet pressure is too low.
- Q:What are the general water pump failure, how to repair?
- (4) because of the long latent water and the corrosion of the pipe wall, the water inlet of the water inlet is constantly dropping. When the holes appear above the water, the air enters the water inlet pipe from the hole.(5) there is a crack at the bend of the inlet pipe, and there is a small gap between the inlet pipe and the water pump, which may cause the air to enter the inlet pipe.
- Q:How many concrete pump tube diameter
- High pressure is the outer diameter is Phi 140 Type 150 type low pressure pipeline; pipe diameter is Phi 159 pipeline, high pressure pipeline diameter is phi 168.
- Q:Why is the flow of the pump too small will occur cavitation phenomenon?
- This is because the impeller of the centrifugal pump rotating speed under the drive of the prime mover, when the valve opening decreases, flow rate is too low, can not be taken away by the friction heat generated by the impeller and the liquid completely, make the temperature of the liquid inside the pump. Thus causing liquid vaporization, forming cavitation. Especially in the power plant, the boiler feed pump is more remarkable. Therefore, when throttling regulation, we should set up recirculation system, increase the output flow of the pump to prevent cavitation. When the feed water rate is reduced to 1/3 of the maximum flow rate, the recirculating gate shall be opened so that the flow of the feed pump will be increased properly to ensure that the liquid temperature in the feed pump does not rise.
- Q:What should I pay attention to when buying a pump?
- There are hundreds of water pump manufacturers in China, some of the family owned private enterprises are assembled in some areas, and the quality of the products is very good and bad, which makes it difficult to choose and buy. The main points are as follows:First, according to the required flow, lift, shaft power, efficiency, the necessary cavitation margin (or suction) and the use of conditions, the initial determination of the pump type, name, select the rated value and the required parameters of the same pump.
- Q:The difference between submersible pumps and centrifugal pumpsWhat's the difference between the two? What is applicable and what?
- Difference:The installation position is different: one can discharge water, one is on the ground.The work principle is different: the principle of submersible pump is similar to the electric fan, centrifugal pump through centrifugal force to make the water throw out. According to the principle of centrifugal force design,
- Q:How accurate is the metering pump?
- Three automatic compensation valve device widely used in diaphragm metering pump, especially with suction height requirements, can only be used by three separate Fujian (safety valve, discharge valve and oil supply valve) compensation device.
- Q:What is the difference between an air pump and a water pump?
- The air pump (Q. B ng air pump), namely "air pump", a device for removing air or add air from the enclosed space from a closed space. The air pump is mainly divided into an electric air pump and a manual air pump. Electric air pump. An electric pump powered by electricity; produces air pressure by constantly compressing the air through electricity. Mainly used in pneumatic rubber, car inflatable, etc..
- Q:What does "dual purpose" of water pump mean? Please expert advice
- 2, the pump must pay attention to maintenance after use, for example, when the pump is used up, the water pump should be put clean, it is best to remove the water pipe, and then rinse with water.5, the water pump on the tape should be removed, and then rinse with water after drying in the light place, do not put the tape in the dark damp place. Water pump tape must not be stained with oil, not to tape coated with some sticky things.6, to carefully check whether there are cracks in the impeller, the impeller fixed to the bearing on whether there is loose, cracks and loose if the phenomenon to be timely maintenance, if the water pump impeller should also be above the earth clean.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Horizontal Booster Water Pump for Boiler Feed
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Related keywords