• butterfly valve Triple-eccentric design System 1
butterfly valve Triple-eccentric design

butterfly valve Triple-eccentric design

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing



Quick DetailsStandard or Nonstandard:  Standard Structure:  Gate Pressure:  Medium Pressure

Power:  Manual Material:  Casting Temperature of Media:  Medium Temperature

Media:  Water Port Size:  DN40mm-DN300 Place of Origin:  China (Mainland)

Model Number:  GF4 resilient gate valves:  resilient seat flange


Packaging & DeliveryPackaging Detail: air plastic bag inside/wooden box outside

Delivery Detail: 15-60days


SpecificationsDIN3352 F4 resilient seat flange gate valves

1.s:DN40-DN300 ize

2.medium:water

3.standard:DIN

4.certificate:ISO9001 CE


resilient gate valves

1.size:DN40-DN300

2.medium:water

3.certificate:ISO9001 CE

4.standard:DIN


available medium:water

working temperature:≤80oC


flange dimensions:DIN2501


Q: does it come in when you go over a certain rpm or do the valves change depending on how far you depress the throtle?
The variable is the valve timing. The spark plug fires a split second before the piston reaches the top of the stroke, to give the fuel a bit of time to burn. But, the faster the piston travels in the bore, that split second gets shorter shorter. So the engine computer changes when the spark plug fires when the valves close, to maximize the power from each ignition stroke.
Q: I got my timing belt done on a 1999 Civic Si on September 26 @ 113,699 miles. at 116,9xx miles I bent a valve on my third cylinder. How likely is it that the timing belt is the reason why this happened? I heard that if the timing belt is a tooth or so off, it could bend a valve. So is it likely that this could have happened? Anyway to check?
Yes, unless you've left out a critical detail (such as getting water into a cylinder), the timing belt is the most likely explanation for your bent valve. It doesn't neccessarily mean the person who 'did' your timing belt buggered it up, it may have just slipped. The short-ish period between getting work done and the valve getting bent is a little suspicious, but slips happen, especially with belts (as opposed to chains and dual row chains). This puts you in a difficult situation. You may also want to inspect your valvetrain, piston face, and the bore of that cylinder for damage.
Q: When will Butterfly Valves be used?
Butterfly valve is the most common and most widely used in the field of the valve, cases of sewage treatment, water supply, iron and steel, building construction and heating fields needs a lot of valves, especially with the hard seal butterfly valve butterfly valve position and a lot of popularity, the field is used more widely.
Q: Butterfly valve flow direction is single or two-way?
Hello, soft sealing butterfly valve is generally two-way flow, large bore with flow direction is one-way flow. Hard sealed butterfly valves are the same.
Q: How big is the butterfly valve with a diameter of 80?
Generally speaking, especially small caliber, the butterfly valve will not use the variable diameter. Therefore, the butterfly valve DN and pound class selection, according to the field pipeline flange DN and pound level.So, in a strict sense, the caliber of the butterfly valve and the diameter of the pipe have not much relationship.Specific to your pipe diameter, there are questions: 80 diameter refers to the outer diameter or inside diameter? Yes, there is no flange on the site. Do you need a pair of flanges to be supplied?
Q: Gate valve, butterfly valve and so on can do the valve so that?
Valve can not be used to adjust the use, if the switch can not be in place, the medium flushing gate valve is easy to cause poor sealing!
Q: How do the butterfly valves d341 and d343 differ in appearance?
Also known as butterfly valve, control valve has a simple structure, can be used for low pressure pipeline valve switching control is closed parts (disc or disc) is a disk, around the valve axis to achieve the opening and closing a valve, the valve can be used to control the flow of air, water, steam steam, all kinds of corrosive medium, mud, oil, metals and radioactive liquid media and other types of fluid. On the pipeline, mainly from cutting and throttling. Butterfly valve headstock is a disc shaped disc, in the valve body around its own axis of rotation, so as to achieve the purpose of opening or closing or regulation. According to type code, transmission mode, connection form, structure form, sealing surface material or lining material, nominal pressure, material of valve body, regulate butterfly valve type.
Q: Butterfly valve sealing material has several?
Nine: X1 (natural food gum), X2 (Heipalen), X3 (ethylene propylene rubber), X4 (neoprene), X5 (Ding Qing X6 (rubber), wear-resistant rubber (FPM), X7), X8 (silicon rubber), X9 (heat resistant ethylene propylene rubber)
Q: What's the difference between electric butterfly valve and electric two way valve?
The valve can only be fully open or fully closed, so the controller only need a 1/4 angle stroke in control, so you only need to open and closed position control. The butterfly valve can be opened and closed at any position within 90 degrees, so a positioning device is needed on the electric head. If the valve is used (such as double eccentric butterfly valve or three eccentric), due to the eccentric effect, need to always have a butterfly valve opening and closing positions to control the torque of Disc Edition in the stem, especially in the valve closed to non preferred direction needs a torque to ensure the butterfly valve, which requires control device to provide a torque to make butterfly valve position or seal. Therefore, the ball valve only needs to drive device to meet the opening and closing, two positions can be, and butterfly valve but in the switch of the whole trip in the control.
Q: i just finished installing a sprinkler line for my lawn and i used anti siphon valves and 4quot; sprinkler heads. it says in the manual that it has to be at least 6quot; from the highest sprinkler. i think i made a mistake. i installed it 7quot; from the highest 'sprinkler line' . will i have a problem with that regarding the operation of the anti siphon valves and the sprinkler system itself?
as you stated, you said the directions said at least 6 from the highest sprinkler 7 will be ok as well as 20. i don't know what region you are in, but if you are in a freeze zone though it is always a good idea to blow the lines when winter comes around.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords