• Single Core PVC Insulated Flexible Cable 300 /500V RV System 1
  • Single Core PVC Insulated Flexible Cable 300 /500V RV System 2
  • Single Core PVC Insulated Flexible Cable 300 /500V RV System 3
Single Core PVC Insulated Flexible Cable 300 /500V RV

Single Core PVC Insulated Flexible Cable 300 /500V RV

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1000 m
Supply Capability:
30000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Single Core PVC Insulated Flexible Cable 300 /500V

Production Introduction for Single Core PVC Insulated Flexible Cable 300 /500V:

Voltage Rate: 300/500V, 450/750V

Cores: 1~5 cores

Range of Nominal cross section: 0.50 mm2 ~ 120 mm2

Conductor: Class 5 fine annealed copper wires

Constructions:Insulation: PVC  

Core color: Brown, Grey, Black, Blue, Green/Yellow or others on request

Max. Operating Temperature: 70, can be 90,105as per requirement

Packing: 100 meter/roll for small size, wooden drum for big size, or as per requirement

 

Application for Single Core PVC Insulated Flexible Cable 300 /500V:

Flexible wiring, for switch control, instrumentation panels and for internal connection.

 

Production Standard for Single Core PVC Insulated Flexible Cable 300 /500V:

IEC 60227, BS6500, VDE0281, GB/T 5023, JB/T8734

 

The  Feature for Single Core PVC Insulated Flexible Cable 300 /500V:

The cable can be of flame retardance, fire resistance and other property

 

Packing photo for Single Core PVC Insulated Flexible Cable 300 /500V:



Single Core PVC Insulated Flexible Cable 300 /500V RV

Single Core PVC Insulated Flexible Cable 300 /500V RV

FAQ For Single Core LSZH material Insulated Fire retardant Cable 450 /750 V:


Q1:What is the Production Capacity for your factory?

About 100 kilometer every day

 

Q2: What is the Minimum Order Quantity For Single Core PVC Insulated Cable 450 /750 V?

MOQ: 10000 meters for small size, 5000 meters for middle size, 1000 meters for big size

 

Q3:What is the delivery time for these cables?

10~15 working days

 

Q4: What standards is the product complying with?

    We can produce thousands of electric wires and power cables complying with different standards, such as: GB, JB , IEC, BS, AS/NZS, VDE, UL ETC.



Q:Ever time I try screwing in my power cable sparks fly.My amp has no off switch.and my car is turned off.wtf?Help me out/
Very simple...remove the negative clamp from the battery in your car before you attempt to do any thing. now the circuit is broken... make sure your ground for your amp is going to something metal on your car... I imagine you are trying to hook your power cable to the positive clamp on your battery... After the amp is grounded. you may now hook-up the power cable on to the positive terminal of the battery. tighten the positive terminal with your amp power line together. Then when you are sure the amp is grounded...( ground wire to metal )...you have a ground wire from the amp also. take the positive battery post wire and reattach... then the negative battery post wire... the battery wires sould not get hot or change temp, you will know as it happens quickly... now if all the wires are done right and your cables don't heat up, it is safe. if you turn on the stereo now and it dosen't work, it just means you blew the fuse on the line to the stereo. find on the line, replace it... it is a safety thing so you don't blow the amp or burn the car down... When ever you work on a car always remove the NEGITIVE post on the battery...
Q:Things to think about: -valley has steep sides -the slopes are rain forest or small villages -no roads built in the area -the cable towers are 5000 ft apart at some points, but others only 3000 ft -the towers are 15000 ft above the floor, others only 500 ft*activities must not create significant noise*Cables are not allowed to sag below 120 its for my technical report for civil engineering technology....any ideas will help even the craziest ones..thankss soo much
That's a long span, but not impossible. You might want to check out the Ameralik span in Greenland for some ideas (it is about 3 times that long, at 5376 meters) Here's one reference:
Q:I have a power adapter that changes the tip of a power cable from the US standard to the Spain standard. My laptop has 3 prongs and the adapter accepts 2. It fits into it, but the 3rd prong just rests outside. I know the voltage over there is twice as strong, so will this work correctly?
i hope to goodness this is not just a gimmick that changes from round plugs to flat plugs...make sure it down-steps the voltage too!!! but otherwise, yeah. the third prong is not essential in any country, it's just a safety feature - many homes in the US even don't have it. my one friend installed fake electrical sockets that have the hole for the third prong (but the hole is not connected to anything) and her laptops work fine.
Q:Why is the terminal metal housing of the power cable to be grounded?
How to say that interference is certainly some, if you line less words on one or two in the bridge next to do a tube it! The pipe will be a little better. Upstairs that I do not think that although in practice the construction of this practice a lot, because you do not feel the interference, but the reality does interfere with, or science should not be strong and weak must be separated.
Q:Does anyone know if this PSU comes with a power cord/cable? I can't find an answer for this.
Psus usually come with one, if not the cable is universal and is dirt cheap
Q:I have a be quiet! dark power pro 850W. The sleeving is too thick for cable management!! It is a complete mess with the antec 900. its ridiculous as I bought it with cable management in my mind. Can I buy thinner cables on their own? Is there a standard modular fitting size?Thank you.
the capability connectors that plug into the slots on a modular capability furnish are no longer common -- they are particular to that distinctive style of furnish (there is a few standardization for modular PSUs made by a particular producer, yet i does no longer even confirm approximately that). So, in case you opt for further cables, you ought to touch client service on your style of PSU or examine help boards at their internet site to work out what the technique is for paying for them.
Q:my MOBO has a 4 pin connector, but my power supply came with an 8 pin power cable, so what do i do? Also my MOBO has a SATA1 slot by itself, and two SATA slots called SATA 2 and SATA 4. The SATA 1 is by itself, and SATA 2 and 4 are next to each other. so which SATA slot do i plug opticaldrive and HDD in?
This is about power connector -
Q:My old card only needed one of these cables. but my new 4870 will need two. can i just use a IDE-to-PCI-e power cable? its only got 3 wires out of the 6 though. does this matter?
You okorder /... It takes two 4-pin PSU molex connectors and converts it into 1 6-pin PCIe connector. Make sure your PSU can supply the necessary amps on its +12V rails, and if you got a PSU with multiple +12V rails, you need to make sure you got the load spread out among different rails to avoid overloading one rail.
Q:The Power cable of my guitar amp (roland cube 20x) was under my computer chair leg and when i sat down the fuse triped in the power box then when i checked under me the cable was almost cut across.. How can i fix this or where would i get it fixed?
Just splice the cable - no need to open the amp. Cut the damaged cable just above where it is damaged. Cut and strip the 3 wires. Cut off the damaged section. Cut and strip the wires that are connected to the power plug. Re-connect the two sections using in-line splices and electrical tape (you can buy these at any hardware store). Match up the wire colors. Splices look like this: mahathon .th/products_detail.ht... If you do a good job, that should last a long time.
Q:I want to hook up (charge) my iphone AND my radar on my motorcycle. My radar is already wired to the 12v cable in my bike. Now can I hook up the iphone to the same cable? or is it gonna be drawing too much power? thxI was planning on buying the cigarrete lighter thing, and pluging the iphone into that. I'd obviously hook up the cig lighter to the 12v cable.
Should be ok. The current draw of these gadgets would be minimal,I would guess 5A tops

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords