AC Solar Water Pump for Irrigation Purpose
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 3000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1. Description of solar pumps.
CNBM Solar Water Pump is the pumping facility driven by solar energy, which consists of a solar pumping inverter and a pump. Solar water pumps kit is called solar pumping system combining with solar arrays designed according to different head and daily water flow for application. System is widely utilized for agriculture irrigation,desert control,pasture animal husbandry,city landscaping,daily water supply, etc.
In recent years, with the development of photovoltaic products from city application to huge demands of agriculture,pasture,desert areas, CNBM Solar Pond Pump has become the leading products combining photovoltaic industry with traditional industry such as agriculture water conservancy,desert control,daily water supply,city landscaping, etc.
CNBM Solar Pump driven by infinite solar energy, works from sunrise, and stops at sunset, need no connection to grid power nor diesel oil and battery. System can irrigate directly or store water instead of electricity in a reservoir. Solartech Solar fountain Pumps works with sprinkling irrigation, drip irrigation and infiltrating irrigation facilities, can be more efficient for water saving and dramatically lower the cost of using fossil energy.
2. Technical Function
1> High efficient DC brushless motor requires less solar array. Rich social benefits.
2> Optional centrifugal pump for big flow and helical rotor pump for high lift.
3> High efficient semiconductor device used in main circuit. High reliability. Up to 98% conversion efficiency of controller.
4> Independent intellectual property of dynamic VI maximum power point tracking (MPPT) algorithm. Fast response and good stability. 99% MPPT efficiency.
5> Full automatic operation. Complete protection functions. Integrated with water level monitor to prevent
overflow and dry running.
6> Full aluminum alloy case. IP52 protection grade. Ambient temperature: -20~+60℃.
Product Specifications
3. Specification details.
1> Flow: 0.4m³/h~22m³/h
2> Head: 10m~210m
3> Power: 0.1~3Kw
4. FAQ
1> May we ask if the bare pump or the whole pump system would be all right for you to arrange the delivery?
The bare pump and the who systems would be all acceptable at your side. A controller will be equipped with the pump freely. Regarding the whole system, we can also make the best solar panels configuration according to your requirements.
2> Does your controller have the MPPT Function?
Yes, our controller have. This would be not a problem.
3> Can your pump work automatically?
Yes, it would be the basic advantage of solar water pumps.
- Q: Troubleshooting of diaphragm pump
- The ratio of flow to water weight at a specific weight of --68F. 68F water has a specific gravity of 1Static suction head - the vertical distance from the liquid level to the central line of the pump. The pump shall be above the level of the liquid.Vapor pressure the pressure of all the steam on the free surface of the liquid. In any pump operating system, the operating pressure shall not be lower than the vapor pressure, otherwise the steam will be partially or completely cut off into the pump fluid. Viscosity - because of the presence of friction in the fluid, the property of viscosity gives the fluid resistance to flow.Water hammer action -Water hammer is a sudden power failure, or in the valve closed too fast, due to pressure, flow of inertia, produce water shock waves, like hammer hammer, so called water hammer. The force produced by the flow of water shock waves can sometimes be very large, thereby damaging the valves and pumps. Water hammer effect refers to the inside of the water pipe, the pipe wall is smooth, flow freely. When the opening of the valve suddenly closes, the flow of water to the valve and the tube wall, mainly the valve, will produce a pressure. As the pipe wall is smooth, the subsequent water flow in the role of inertia, the fastest reach the maximum and damage, which is the water conservancy "water hammer effect", that is, "positive water hammer.". This factor should be taken into consideration in the construction of water conservancy pipelines. On the contrary, the valve closed in a sudden opening, it will produce water hammer, called negative water hammer, but also a certain destructive power, but not the former big.. Causes and treatment methods of common failures of diaphragm pumps:
- Q: What are the functions of a disposable infusion pump?
- With the development of science and technology, more and more fields need to control the flow or velocity of fluid accurately. For example, the detection and analysis of micro chemical elements in chemical industry always need to control the flow accurately. In the field of health care, the flow and velocity of traditional Chinese medicine liquid must be controlled accurately.Venous transfusion is one of the most commonly used methods of clinical treatment. It is a common medication and treatment technique for nursing specialty. Clinically, appropriate infusion rate should be applied according to the drug and patient's condition. Transfusion too fast may cause poisoning, more serious can lead to edema and heart failure;
- Q: How to select metering pump head?
- When it comes to metering pump heads, the usual problem is when they measure acid, chlorine, fluoride, and hydrogen peroxide. Due to the difference in concentration and operating temperature, it is difficult to determine the specific pump head material.
- Q: Water pump outlet valve sequence
- In order to prevent the generation of water hammer when the pump stops the damage to the rubber head, should be immediately set rubber head pump outlet, the gate valve and the check valve is not a very convincing reason to decide the order of habits in our hospital order rubber head, check valve, gate valve1. Check valve located in front of the pump, I do not know what the significance is too great to think of.2. The actual installation sequence shall be: soft fittings, check valves, gate valves. The pressure gauge is best installed on the water outlet of the pump, but it must be in front of the check valve.Reason: 1) the soft joint is used to reduce vibration. The connection between the pump and the piping system, of course.2) normal work, the gate valve is not operating, and the check valve is frequent action, so the probability of maintenance is larger, when the maintenance of the pump closed, the water outlet valve can be maintained without affecting the normal operation of the system.3) the pressure gauge is installed in the check valve, which can prevent the impact and damage of water hammer on the pressure gauge.
- Q: Water pump can not be pumped out, how to maintain water?
- Packing overheating:Due to packing too tight, the cooling water can not enter the filler, or the shaft surface damage. Measures for proper relaxation of packing and cleaning of sealing pipe are adopted. Filler wear must be replaced with new ones. Before installation, soak in the oil and rotate it in turn. The incision should be staggered so that water leakage can be reduced. Fill the last lap after installed loading pressed to cover operation for further adjustment of the tightness.
- Q: What are the basic technical parameters of the pump?
- The basic parameters of the pump, the basic parameters of the main performance parameters of pump are the following: first, water pump flow Q flow is the amount of liquid in the pump unit time delivery out (volume or quality). The volume of flow with Q that the unit is: m3/s, m3/h, l/s and so on. The quality of flow unit is expressed in Qm. T/h, kg/s and so on. The relationship between mass flow and volume flow is Qm= P Q density in P - liquid (kg/m3, t/m3), room temperature water P =1000kg/m3.
- Q: The main factors affecting the performance of centrifugal pumps
- The low specific speed pump, on the other hand, is suitable for smaller flow and higher lift. When the pump outlet pipe diameter at the same time, if the two pumps flow similar, smaller than the speed of small head, shaft power consumption is also large. Generally speaking, the centrifugal pump with smaller revolutions than the impeller has a narrow outlet width and a large outer diameter, and the channel formed by the blade is narrow and long. If the ratio of revolutions is large, the impeller outlet is wide and the outer diameter is small, then the flow passage is short and wide.I hope my answer will be helpful to you. I hope to adopt it!
- Q: How many pumps does the 80cm tank use?
- For example, you are 80 cm tank, assuming you are 40 cm wide, the water surface is also 40 cm, then the final count by 80X40X40=128000 cubic centimeter, that is, 128000 ml.
- Q: What is the difference between centrifugal pump and self suction pump? Which is better?
- If the centrifugal pump in full before the start of the shell of the gas, then start after the center of the impeller was thrown in the gas can not be large enough to form the vacuum, so that liquid in the bath can not be sucked, so the centrifugal pump to start before using foreign liquid in the pump housing space filling
- Q: Significance of water pump model ISO50-160
- Meaning of water pump model ISO50-160: ISO- stands for international standard code (IS). 50- indicates that the inlet diameter of the pump is 50 mm (the complete model IS50-32-160 32- indicates that the outlet diameter of the pump is 32 mm). 160- represents impeller diameter.
Send your message to us
AC Solar Water Pump for Irrigation Purpose
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 3000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords