Product Description:

Production outline
Model SLS single-stage single-suction vertical centrifugal pump is a high-effective energy-saving product successfully designed by means of adopting the property data of IS model centrifugal pump and the unique merits of vertical pump and strictly in accordance with ISO2858 world standard and the latest national standard and an ideal product to replace IS horizontal pump, DL model pump etc. ordinary pumps.The flow range is 1.5 -2400m³/h and the head range 4.5~160m and there are basic type, by-pass type, A B C cutting type etc. more than 250 specifications. And per the different flow medium and temperature, SLR hot-water pump, SLH chemical pump and SLY(YG) oil pump and SLHY vertical non-explosive chemical pump. etc. Series products. of the same type and same proprty data have been designed and made.
Product feature and advantage
1.Compact structure, small volume, beautiful outlook.The lower barycenter of the vertical structure which coincides with the center of the pump feet strengthens the stability of running and the duration.
2.Easy to mount. Because of the same apertures of both inlet and outlet which also locate on the same central line, the pump can be directly mounted on any part of the pipeline just as a valve. The motor is covered with a rainproof cap so that operation can be done outdoors. Mounting feet are equipped with the pump so that it can be stably mounted.
3.Stable running, low noise, high concentricity of components. Bearings of low noise are used for the motor, the impellers are of best dynamic and static balance, no vibration at running and the environment thus being improved.
4.No leakage. The shaft is mechaically sealed with carbide alloy wearable material, settling the serious leakage of the filling seal of a centrifugal pump, extending the duration and ensuring the operation place clean and tidy.
5.Easy to maintain. Not necessary to remove the pipeline for check-out and maintenance, only to take out the nuts on the pump lid, the motor and the driving components.
6.The pump, according to the operation condition of the worksite, may be vertically, horizontally etc. multiways mounted and also according to the requirements for the flow and stroke, mounted in parallel and/or in series to increase the needed flow and head.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:The reason why the pump is overloaded
Main reasons: 1. bearing lubrication is not good or bearing quality problems appear peeling phenomenon, resulting in increased resistance to pump operation.2., the pump cover and impeller clearance is too small, the impeller mouth and pump cover friction.3 belt tight, resulting in heavier load.4. centrifugal pump power is proportional to the flow, the greater the flow, the greater the power needs, large, low head flow, resulting in heavy load.Water pump maintenance: 1., water pump to do routine maintenance, check the water seal every day, to prevent water damage, water directly into the bearings, accelerated wear and tear.2. belt adjustment should be appropriate, not too loose, too tight.3. strictly according to the standard operation, for the low lift pumping load, it is necessary to control the flow by throttling, thereby reducing the load.
Q:What is LG water pump?
LG pump LG refers to the name of the water pump brand, not on behalf of practical significance.LG pump is a high-rise building feed pump.1, LG, LG-B type of high-rise building water supply pump is a vertical multistage type structure, bolt the inlet section, the middle section of the water pump are fixed together, each containing a impeller and the guide vanes, the axial force of the hydraulic balance, the residual axial force by one or a pair of ball bearing;2, the shaft seal adopts special design mechanical seal, so when dismantling mechanical seal, do not need to remove the motor, the middle casing coupling can be removed from the seal, it has the advantages of replacement and convenient maintenance;3, pump transmission is through the shell coupling, vertical motor drive, from the motor side to see, the pump clockwise rotation;4, the suction inlet of the pump is below, the water outlet is above, and its relative position can be chosen according to the user's requirements, 0 degrees, 90 degrees, 180 degrees, 270 degrees for assembly, factory. General pump 180 degrees factory.5, assembly without adjustment, easy disassembly;6, the motor can be equipped with standard Y series of ordinary models.
Q:About water pump selection
0.1MPa 1, according to the water pressure of the hydrant, dry season difference 17m geometric head for 17m, the pipeline resistance calculated according to 10%~20% 1.7~3.4m, from 3m, so the pump head should be 17+3+10=30m, considering that this is the dry season conditions, when the water level elevation is lower than 17m when the actual demand of low lift in 30m, it is not recommended to 35m head to head design, 30m under various conditions are enough (the actual operation of pump lift by lift device, so if the head is too high may lead to the actual use of pump bias conditions, and low lift and large flow operation, the flow of super power) selection of I don't know your personal needs, can not make a judgment, suggestion the flow rate and pipe diameter according to the economic flow rate of 2.5m/l is about to take it.2, from the operation of the pump, it is best to water intrusion, is higher than the pump center line, so it is best to get the pump installed under the negative on the second floor, if you can not meet the high water pump and the center line, there are three choices in the selection of a pump: 1, submersible pump (by landlord excluded); 2: the ordinary centrifugal pump + water diversion device (water diversion valve then available irrigation water or vacuum diversion device, this approach might not be used, and irrigation valve trouble, valve is broken with it, such a small pump vacuum water cost is too high); 3: self suction pump. Recommendations may consider self suction pump, self-priming pump is also divided into no sealed automatic control self-priming pump and general cantilever self-priming pump both, but the installation height is still lower, the better, because the lower the water level of the entrance, the more likely to suck water.
Q:TDH what units are present in the pump parameters?
In the pump parameters, TDH is the head of President (Ying Chi).The formula is as follows:TDH (Ying Chi) = total head (Ying Chi) = (- water pressure readings + drainage pressure gauge (drainage dynamic head - water head + (drainage pressure gauge - water pressure elevation correction table elevation correction)
Q:Relationship between power and flow of sewage pump
Severe N= gamma gamma ETA QH/1000 liquid (ox / m3) - N- power efficiency eta (kW/h) - head of M Q- volume flow (M / sec)1, power *0.6= flow * lift *9.82, for the water treatment industry, the flow of cubic meters / hour units,Power = (flow * lift *9.8) / (3600*0.6)3, power = flow * lift *0.0045 (general 50%--90%, large pump higher)
Q:Multi storey residential buildings also need to set up pressurized water pump room, direct water supply can not be?
Some water pressure is not enough, and since you are multi-storey, you need to add booster pump downstairs
Q:How much is the flow rate of fire hydrant and spray shared water pump?
Fire fire water is superimposed, at the minimum, the lowest 5L/S automatic spraying fire hydrant, light danger level 13.9L/S, the least is 18.9L/S, but the data is useless, the data are not spraying fire hydrant, concrete analysis of high-rise buildings like the dangerous level according to the calculation, the general design, the concrete building needs the high-rise building minimum 20L/S, automatic spraying dangerous level according to the general 30L/S, 50L/S need to flow.Fire hydrant: fire hydrant (English Name: fire hydrant), a stationary fire fighting tool, with 4 iron chains. Fire hydrants are provided throughout the city to provide fire water for firefighters during the rescue. The main function is to control fuel, insulate combustion and eliminate fire source. The fire fighting system includes outdoor fire hydrant system, indoor fire hydrant system, fire extinguisher system, and some automatic sprinkler system, water gun system, gas fire extinguishing system, fire detection system, water mist system and so on. Hydrants are mainly fire engines from the municipal water supply network or outdoor fire water supply network to implement fire fighting, but also can directly connect hoses, water cannons, fire extinguishing. Therefore, the outdoor fire hydrant system is also one of the important fire fighting facilities.
Q:Why is the minimum liquid temperature allowed at 2 DEG C instead of 0?
0 degrees water turns into a mixture of ice water. Do you think the water pump will work properly?
Q:Think of several households sharing a pump
Each contactor is connected with each power source in the main circuit, and the lower port is connected to the water pump;Control loop, only draw the wiring diagram of A households, households in other similar first power through the control switch in series contactor several other a normally closed contact and then enter the M contactor coil;In water, leading to various water pipes connected with the electromagnetic valve, and the solenoid valve are connected in series and the two contactor normally open contact is connected to the power supply;As long as one of the closed control switch, the pump will run at the same time, using his own power, and this is the other an open pump closed control switch of their own, will not work, the water will not go into his house, the family will not run electricity; only when the first home after closing the control switch second, if still closed control switch, water and electricity will automatically turn to him.Not understood, of course, that there is one drawback, if one is using a pump, a few other can not be used to solve the problems, it is not difficult, is that every installation of a water tank or like a floor, said each install a pressure tank on it
Q:The problem of single phase pumps
The capacitor is broken. Change it.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range