• Monel 400 wire/ASTM B164/ Nickel Alloy wire System 1
Monel 400 wire/ASTM B164/ Nickel Alloy wire

Monel 400 wire/ASTM B164/ Nickel Alloy wire

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100000 m
Supply Capability:
1000000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Product Description

Monel 400 

Chemical Element: 
Ni 63.0min, Cu 28min~34max, Fe2.5max, Mn 2.0max, C 0.3max, Si 0.5max, S 0.024max 

Characteristic as below: 
Monel 400 is an extremely combination property that use for largest amount and most widely corrosion resistance alloy. This alloy in the hydrofluoric acid and fluoride gas medium with excellent corrosion resistance, as well as to the hot concentrated alkali. At the same time, is also corrosion resistant to neutral solution, sea water, air, organic compounds. An important feature of this is generally do not generate a stress corrosion cracking, good cutting performance. 

Metallurgical structure 
Monel 400 alloy is high-intensity single-phase solid solution. 

Corrosion resistance 
Monel 400 alloy in the fluoride gas, hydrochloric acid, sulfuric acid, hydrofluoric acid and their derivatives have a very good corrosion resistance property, and possess better corrosion resistance more than the copper alloy in the sea water. Acid medium: Monel 400 have corrosion resistance in less than 85% consistency of sulfuric acid. Monel 400 is an important material that resistant to hydrofluoric acid. Water corrosion: Monel 400 alloy in most corrosion cases of water, not only excellent corrosion resistance, but also less pitting, stress corrosion, the corrosion rate less than 0.025mm / a. High temperature corrosion: Monel 400 for the work of the highest temperature at about 600 degree in general in the air, in the high temperature steam, the corrosion rate less than 0.026mm / a. Ammonia: Monel 400 can be resistant to an hydrous ammonia and aminate conditions corrosion below 585 degree due to the high nickel. 

Application field: 
Monel 400 alloy is a multi-purpose material in many industrial applications: 
1. Seamless water pipe in the power factory 
2. Sea-water exchanger and evaporator 
3. Sulfuric acid and hydrochloric acid environment 
4. Crude distillation 
5. Sea-water in the use of equipment and propeller shaft 
6. Nuclear industry and used in the manufacture of uranium enrichment isotope separation equipment 
7. Manufacturing hydrochloric acid equipment used in the production of pump and valve. 

Our company supply monel 400 wire, monel 400 flat wire, monel 400 strip.


Q:i bought a duct fan that says to connect the wires (black, white, green) into the wires in the walls. can i wire the fan to an extension cord and then plug that into the wall instead of connecting to wires in the wall?
NO all wire junctions must by code be made in a junction box, and it MUST be accessible. Find the nearest junction box, if the circuit isn't going to be overloaded, tie into that with 12/2 romex, run that to your fan and hook them up to the fan inside the junction box on the fan. Do it right and safe.
Q:Why should the wooden pole be burned and buried again?
How do not consider the wireless network receiver problems? Carefully look at the instructions need no external power supply.
Q:How does electrical field spread through the wire when there is potential difference on its edges?
as current flows
Q:How much power does the ten square power line carry? How many kilowatts?
And the thermal pipe ditch parallel to the distance of 2 meters, the special circumstances can be reduced and reduced by half the value; cross-distance 0.5 meters, separated by a partition or cable pipe can be 0.25m see GB-94 Table 5.3.5 2006 version of the basic out or the implementation of this, to the local power supply management advice prevail
Q:I purchased at Ace Hardware a Bell Wire, and it says on the back for low voltage use up to 48 volts it is a solid/very sturdy wire with a green instulation i have three questions;1) can/should i use it to wire 3 3v led's to a nine volt battery or is it to thick of wire?( to thick meaning the 9v wont fill the whole wire resulting in loss of electricity)2) Can/should i wire 2 12v 12amp batteries an extremely short distance with it or is it not of high enough quality(like gauge).3) is there such thing as overkill? ex: using 12 guage wire for 2v or is it just unreasunable to do thatPs. Sorry for all the confusing launguge i dont know all the correct terms, im trying my best.
Those color sleeve wires was designed for the use of telephone line wring. Phone system uses 48V DC power and that is why it marked good up to 48V.
Q:I have a picture of them on my phone. 2 wires are green. The last wire is orange. I couldn't post the pic but I have a pic of it on my cell phone. Thank You, Chris 1986 350 boat engine
There are to many alternators out there to say.Look to see who made it and contact them.Any number on it will be a help when you contact them.
Q:RVV2 * 1.0 is a wire or a cable
This model is soft wire, double core. The cross section is 1mm2. The conductor is copper, the insulation sheath is PVC material.
Q:I have 4 consecutive 110v outlets that are only receiving 82v and the receptacles are not working. I tested them with a multimeter. I tested from both the receptacle and the wiring to the receptacle. What do i need to do to resolve this. The breaker isnt tripped, and the fuses are good. I have checked switches- to see if maybe one needs to remain on for the string of outlets to work, but there doesnt seem to be one tied into them. it is 4 outlets on one side of the living room. no gfi to reset. the house was built in the mid -90's. as far as i know-- there has been no hack job engineering done before i moved in. i bought the place from original owner, and they said its original wiring. any suggestions would be greatly appreciated
Great answer from 'mermeliz'. Please reward it with 10 points. I agree with the probable culprit. Here is a method to find the problem. Not 100% guaranteed, but works almost all of the time. If it doesn't, you will be stuck opening each receptacle on the circuit until you find the problem. Turn on all of your non-working lights and plug lamps into any non-working receptacles. Make sure that any computers, or other sensitive electronics are not plugged into this circuit. Take a lamp or an extension cord around to the all of the receptacles on this circuit. DON'T rule out the working receptacles either. Try them too. Plug it in and wiggle the plug (hard enough to wiggle the receptacle too). You will probably find one where doing this suddenly causes your non-working lights/receptacles to come back to life. This will be your culprit. As 'mermeliz' correctly stated, a lot of homes are wired with receptacles using 'stab-in-the-back' connections. These are actually still in use and are deemed safe for installation. The problem is that they have a terrible failure rate. The term 'stab-in-the-back' also applies to what they do to you later. Any replacement should have screw terminal connections.
Q:Every few months between 2am - 5am we are awaken to a electrical/fire burning smell. It only last about a minute and then it starts fading. We get up trying to locate it but with it only lasting a minute we can't pin point it. We unplug everything and smell all the electrical outlets and there is nothing. What else should we try?
Check your refrigerator, may be the defrost system malfunctioning. Check your outlets for problems. Smell all appliances when this happens. Check your wiring if it is up to code. Last thing you need is to have a fire
Q:fore an electric stove of 3000 watts, taking into consideration that the voltage in my country is 220volts
Follow the link below and go to the theory page. It has all the formulas necessary for you to find what you're looking for. Good luck.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords