Galvanized Straight Wire GI Binding Wire Electro

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1000 kg/m²
Supply Capability:
10000 kg/m²/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

 1.Product specifications.

   Electro galvanized iron wire ranging from BWG8# to BWG16# is the mostly used for customers. Single coil package for electro galvanized iron wire can be as small as 50kg and up to maximum 1000kg per coil.

 

Name:Zinc-coated Steel Wire(Galvanized Steel Wire Strand)

 

Number of wire: 7 wires

 

Strand Diameter: 3/8"

 

Grade:EHS Grade

 

Breaking Strength of Strand:68.503KN

 

Weight of zinc-coating: ≥ 259g/m2

 

Elongation(L=610mm): ≥ 4%

 

Lay:  left hand 

 

Surface:  hot dipped galvanized

 

Raw Material: Q195,Q235,45#, 60#,65#, 70# ,80#,82B# carbon steel 

 

Packing length:250ft /500ft /1000ft /2500ft /5000ft /wooden reel on pallet 

 

2.Zinc- Coated  of steel wire strand  Grade

 

   Class A and  Class B and ClassC

 

 

3.Standard : ASTM A475  , ASTM B498  ,BS183:1972 ,IEC ,GB , ASTM  A363

 

4. Application : Galvanized steel wire strand /guy wire /stay wire is used for ACSR  Core , pulling pole ,overhead   conductor, Messenger wire ,Static wire,Guy wire,Guide rail cable


Description of Galvanized Wire/Iron Wire  

 

1.Materials:(a). Mild steel wire (b). bullet wire (c). high-carbon steel wire

2.Wire gauge size: hot-dipped galvanized wire: 8# to 36#(wire diameter ranging from 3.8mm to 0.19mm)
electro galvanized wire: 8# to 38# (wire diameter ranging from 3.8mm to 0.15mm)  

3.Processing: First draw (the material of wire rod to the right wire diameter0---Wire Annealing---Rust Removing--- Acid Washing--- Boiling--- Drying--- Zinc Feeding--- Wire Coiling. 

4.Zinc coating:   8-15g/mm2 electro galvanized, 30-70g/mm2 hot dip galvanized, 100-500g/mm2 heavy duty galvanized zinc coat.

5.Elongation: 10-15% for low carbon steel wire

6.Tensile strength: 350-550n/mm2 soft,550-950n/mm2 hard drawn, 1000-2600n/mm2 high tensile strength.

 

Application Of Galvanized Wire/ Iron Wire

1) binding wire or building wire for construction

2) weaving wire mesh

3) making express way fence

4) handcraft


Galvanized Wire with Diatmeters of Between 0.15 and 9mm

Application

Weaving, braiding, fencing, cable armoring, knitting, tie wire, for redrawn, for binding or forming etc.

Material

low carbon steel wire

Diameter

0.15mm~9.00mm

Tensile strength

350-540MPA, or higher

Zinc coating

Min 12g/m2, min 25g/m2, min 200g/m2,

Surface treatment

Hot dipped or electro galvanized

Packing

On spools of DIN160, DIN200, DIN250, BB20, MP100 etc.

In small coils of 25-50kg/coil, 10kg/coil or even 2-5kg/coil

In rosette coil of 100-800kg/coil

Standard

ASTM 641, EN10257-1& EN10244-2

All can be produced according to customers’ actual requirement.


Packaging & Delivery


Packaging Detail:

coil,spool,piece,rosset coil,drum,cardboard carton

Delivery Detail:

0-4weeks


FAQ:

We promise you as follows:

1.We are local producer,not only trading company ---------------price will be much competitive.

2. We have advanced  professional production equipment-------Product quality will be ensured.

3.We have done international business for long---highly familiar with exporting will be believed.

4. We stick to customers' request-------- best solution will be gave according to your request.

 


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:amp wiring help?!?!?!?!?!?!?!?!?!?!?!?!?!?
If you aare running with 4 gauge right now...your going to want to upgrade power and ground to 1/0 gauge. Your RCA should not have to be upgraded.
Q:Does anybody do it yourself put a new wire onto your phone outside the wire ?
The wire comes down or up to a connection box. This is the place separating yours from theirs. Anything on your side of that is yours and you are responsible for maintaining it. Changing it is not difficult. You need some wire, fittings and a tool to attach the fittings. The peiople who sell that should be glad to explain how to do what. Most of the connection boxes now use a plug-in connector so it becomes a piece of cake. If the wire toward the street from there is the problem, just report it and a staticky phone. That is the phone company's problem.
Q:Question about wires in plugs?
The typical U.S. power distribution system has two hot wires coming into your electric panel, plus a neutral wire. The neutral wire is grounded to earth ground, as is the protective green earth wire. An outlet, carrying 110 volts from one of the hot wires (black), supplies current for the load and it flows back to the transformer on the pole normally via the neutral (white) wire to the center transformer (grounded) tap. The green protective wire does nothing in normal operation. However, should the appliance have a metal outer skin, and the machine develops a short, energizing the outer skin, it will flow through the green ground wire back to the transformer rather than through you and back to the transformer.
Q:How many wires do you go through with braces?
they change your wire according to how much your teeth have shifted around, so it just depends. the ortho needs to adjust the size of the wire due to your teeth straightening out and making sure the wire(s) are at a correct length. its really not that thick of a wire, so don't worry about it. :D
Q:wire length?
The stretching of wire by longitudinal force: If F force applied across the crosectional area A of wire of radius r and lenght L then the wire elaogates in the dirextion of force Stress P = F / A A = pi* r^2 = (1.5/2)*10^-3 = 7.5 *10^-4 m^2 strain produced = dL / L = increase in length / original L Young's modulus or elastic (stretch) modulus for the maretial, within elastic limits, Y = stress/strain strain = stress / Y dL = F * L / A * Y = F * L / pi (r^2) * Y dL = 400* 1.5 / 3.14 (7.5 *10^-4)^2 * 6.2*10^10) meter dL = 0.005479 * meter dL = 5.479 millimeters increase in length
Q:Wiring up an amc ignition coil?
Just go to Summit Racing Equipment online and get either a factory replacement or an aftermarket that has the factory hook ups so you don't have to figure out the wiring. Are you replacing the wiring? is it damaged? You might try painless wiring and see if they have a wiring system for it. Or get a manual with a wiring diagram.
Q:thermostat wiring in an old house?
two wires go to the cooling and two to the heat . Rc is for red wire cooling , Rh is for red heating , i would think the white goes to the W/B ,i would guess the blue wire goes to Y . but you can call the 800 number for tech help
Q:Magnetism question on current carrying wires?
The vertical wire rotates (clockwise ?) Draw the situation where you are looking directly at the 'end' or the horizontal wire with the current coming towards you .. the magnetic field from this current is a set of concentric circles with counter- clockwise direction (using the screw-cap rule.. turn counter-clockwise to move cap towards you as it loosens). Now place the vertical wire in this field (close to horizontal wire) and apply Fleming's left-hand motor rule to find the direction of force/motion for the upward current. Above the horiz wire .. Field (first finger) points left, Current upwards (second finger), Motion/force (thumb) direction is towards you. Below the horiz wire .. Field right, Current upwards, Motion/force (thumb) direction is away from you. Seen from the side this gives the vertical wire a rotation in the vertical plane .. which way depends on which side you view it from. ('conventional' viewing would give a clockwise rotation)
Q:what are the limitations of international wire transfer limit?
Your bank may set a limit on the amount they will allow per wire transfer, but that would be the only limit. My company accepts wire transfers for international business almost daily and there have been a couple of time when I have had to have the purchasing company send a 2nd wire for the balance because the 1st exceeded the banks allowable transfer amount. Of course when that happens you have to be sure that you include the mark up to the customer invoice because you will be charges for each wire transfer by your bank. (some banks don't charge for incoming wires, some do.)
Q:Sony Xplod Amp Wiring help?
its the remote wire. it goes from your amp to the back of your stereo deck. if you have an aftermarket deck ( which i would hope you do) there will be a wire labeled that says remote wire. connect the blue wire with that wire behind the deck. the whole purpose of the wire is to tell the amp to turn on and off with the car.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range