• Cat5e Solid BC Conductor Lan Cable Supply System 1
Cat5e Solid BC Conductor Lan Cable Supply

Cat5e Solid BC Conductor Lan Cable Supply

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
100 Meters m
Supply Capability:
1000000 Meters per Day m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

1)Solid BC conductor cat5e cable

2)CE.ULcertified cat5 cable

3) High quality, factory price cable

 

CAT 5E Cable Assemblies

*Raw material of the conductor solid bare copper

*Conductor Dia 0.575+/-0.003mm23AWG

*2 CENTER CROSS

*3 SHEATH

*Sheath material:LSZH PVC

*Nominal Dia:6.5 +/-0.2mm

*Average thickness:0.60mm

 

Features:

1)Fast and Reliable Connection

2)Good toughness,long transmission meters

3)Twisted pairs with clear color for Easy Recognition

4)Ripcord for Convenience Use

5)OEM orders are acceptable

Q:does it mean some1 died there or what?
i don't know about gang related, but on hway 50 past fallon nevada there is a tree in the middle of nowhere with hundreds of shoes on it, it's huge and like a little rest stop, i don't think there are any gangs out there.
Q:--A wire of resistance 10 ohms is bent to form a circle. Calculate the resistance between two points at the end of the diameter.--I can't understand this. Please show me the steps for finding the answer. I will appreciate your help.
Theoretically - can, but practically u need to check. You consider the the maximum possible measurable length between the two measuring point, as total length of conductor and take twice the cro-sectional area. In practice length is reducing and diameter is increasing so the resistance will reduce. The diameter will be the length here.
Q:All the DIY info shows how to change a light fixture. What do you do with the wiring if you want to remove a chandelier, but not replace it with another?I want to make sure the wires in the ceiling are not capable of starting a fire. This is in the first floor of a two-story.
With respect to the wiring instead of connecting wires to a new fixture they need to be capped with wire nuts instead. With respect to the empty area there are two approaches. If the box is neatly recessed in the ceiling then a larger decorative cover plate will do the job nicely. You do not want to use an electrical cover plate for the normal round box as it will leave unsealed edges around it. If the wires are long and the box is short you might adapt to a wiremold box that will include an adapting plate and the external round box that will project an inch down from the ceiling. Then you will need to add the decorative (wide) blank cover plate. Since you are asking this question there is also an obvious suggestion that you might have someone who is familiar with electrical wiring to do this as someone new to wiring might easily overlook something that a more experienced eye will catch.
Q:I just bought a 30 year old house. My family is just starting to replace the roof, because the shingles and a lot of the plywood is damaged. My dad pointed out that the power enters the house through the roof, and said I should call the power company to have it routed through the side of the house. Is this necessary? Will it be costly? Thank you!
If the wires are in a conduit (pipe), where they go through the roof, that is an acceptable practise. To have them relocated to go through the wall will be costly, as the whole entrance will have to be relocated. I don't know what the regulations are where you live, but here I would have to obtain a permit from the city then hire a electrical contractor to relocate the entrance. When that is completed I would have to get my power provider to relocate the connection, and they would charge for that also.
Q:Hello.I switched over from a gas dryer to an electrical dryer in our home. I ran 10/3 wire from a dp 30A breaker to a 4-wire recaptacle for the dryer.When I turn on the dryer, she spins but no heat.When I checked the outlet, each hot wire to neutral gets 120 volts but between the two hot wires I do not get 240. I then went to the breaker and checked there. Once again 120 from each of the hot wires to neutral, but no 240 volt reading from one hot wire to another. What would be the problem?In fact, when I check any two hot wires on the breaker I do not get 240 volts. Why? I tried swapping out the 30 amp breaker for another one in the event that it was faulty, but alas, still no 240 volts.
You need two breakers for 240.
Q:I am using a 12v dc motor with a DPDT switch and a 12v A23 battery. What thickness or type of electrical wire should I use?
An okorder
Q:I never had this happen before. I had pre cooked bacon in the microwave, on a paper towel and cooked it for 135 sec. This is what I do all the time and never smelled like wires burning. It usually smelled good.
a towel can leave that smell
Q:I installed a ceiling fan/light combo in my room. because of the location of the switches, the switch that controls the light is on one side of the room on circuit 1, and the switch that controls the fan is on the opposite side of the room on circuit 2. What is happening is that there is only 1 common (white) wire coming from the fan/light combo. My circuit breaker keeps tripping if the commons from circuit 1 and 2 are tied together on the one common from the fan/light. Is there a problem with my fan? Is there a problem with tying 2 commons together from 2 different circuits? Is it my fancy CB? (it's one of those new ones required in bedrooms can't remember the name right now). Thought about hooking up a normal CB tomorrow to see if that makes a difference. Any other suggestions?
Sounds like the feeds are at the switches and the neutrals are carried through to the ceiling box.You have to determine which two are the switch legs(hot). When the switch is on check each pair of wires from the switches with a tester the hot ones are the feeds for the fan and light the remaining two are the neutrals. This is one possibility always check with a local electrician if your not sure. We have already established in the question that one switch operated the light and one operated the fan I cant see the use for a three way.
Q:My family is this year's new cover of the color steel room, used in the old house when they are relatively thin wires, electricity is very normal every month, but a move to a new house when the electricity that month A bit too much, or the same electricity habits or those appliances how the monthly electricity will be so much? Where is the place where there is leakage and our home with a rough relationship between the wire? Just try to use a pen, and some places are 12v some places did not show, please know how to help my friends how to analyze ah? Thank you! More
Plastic pipe has a lot of material and a variety of uses, wire tube is just one of its PVC pipe.
Q:How the square of the cable and the current conversion
Two hundred and fifty times multiplied by nine, go up by a straight to go. Thirty-five by 3.. both groups of five points. Conditions have changed, high temperature Jiujiang copper upgrade. Piercing the number of two hundred thirty-four, eight seven six fold full load. Note: This section of the formulas on a variety of insulated wire (rubber and plastic insulated wire) of the current (safety current) is not directly pointed out, but "cross section multiplied by a certain number" to express, through the mental arithmetic derived. As can be seen from Table . the multiple decreases with increasing cross-section. "2.5 points multiplied by nine, go up by a straight run" that is 2.5mm 'and below the various sections of aluminum core insulated wire, the carrying capacity of about 9 times the number of cross-section. Such as 2.5mm 'wire, carrying capacity of 2.5 × 9 = 22.5 (A). From the 4mm 'and above the conductor of the current and the number of cross-sectional number of the relationship is the number of lines along the line row, multiple times by . that is 4 × .6 × .10 × .16 × .25 × 4. "35 by 3.. both groups of five points," said the 35mm "wire carrying capacity of 3.5 times the cross-section, that is 35 × 3.5 = 122.5 (A). From 50mm 'and above the wire, the carrying capacity and the number of cross-sectional relationship between the two into a two lines into a group, multiple times in turn 0.5. That is, .70 mm' conductor carrying capacity of the number of cross-section 3 Times; .120mm "wire carrying capacity is the number of its cross-sectional area of ??2.5 times, and so on.
Guaranteeing stable and timely supply, credible quality and sincere service, our products sell well in both domestic and overseas markets. If you are interested in any of our products, or wish to place a customized order, please contact us. We will do our best to meet your needs.

1. Manufacturer Overview

Location Guangdong,China
Year Established 2011
Annual Output Value US$50 Million - US$100 Million
Main Markets 10.00% North America
10.00% South America
10.00% Eastern Europe
10.00% Southeast Asia
10.00% Domestic Market
10.00% Mid East
10.00% Eastern Asia
5.00% Western Europe
5.00% Central America
5.00% Northern Europe
5.00% Southern Europe
5.00% South Asia
5.00% Africa
Company Certifications ISO 9001:2008;ISO 14001:2004;CE;ROHS

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shenzhen,Hongkong
Export Percentage 51% - 60%
No.of Employees in Trade Department 6-10 People
Language Spoken: English, Chinese, Japanese, Korean
b)Factory Information  
Factory Size: 1,000-3,000 square meters
No. of Production Lines 5
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Low and/or Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products