Why can't autotransformer be used as transformer for safety lighting?
The main and auxiliary coils of the autotransformer have common parts. Once the short-circuit is made, the lighting circuit is directly connected with the high voltage circuit, which is very dangerous
Which is more energy saving by using 24V500W transformer lighting and 220V500W lighting?
If the transformer is not calculated, the loss is the same. If the calculation is the latter, save electricity.
Does the lighting work properly? Doesn't that power equipment start voltage unstable?
Power lines and lighting lines are connected to the same transformer, without affecting the use of a transformer power users, lighting and power are connected together.
How many A leakage protection switches are used in 5000VA lighting transformers?
According to the working principle of the protector, it can be divided into three kinds: voltage type, current type and pulse type. The voltage protection device is connected to the transformer neutral point and the ground, when the electric shock when the neutral point voltage offset to the real estate, in order to make the action to protect the power off, but because it is the protection of the transformer low voltage network, cannot be classified protection, so the power range is large, frequent moves, so has been eliminated. The pulse current protector is a sudden change in the phase and amplitude of the three-phase unbalanced leakage current when an electric shock occurs, which is used as an action signal, but also a dead time. The current type current leakage protector is widely used, so the protector of current type is mainly introduced below.
What's the function of the lighting transformer?
Applies to some requirements for safe voltage 24V - 36V lighting sites. Such as: basement, tunnel, dangerous goods warehouse and so on. Then there is the (mobile, temporary) safety lighting for the overhaul.
The difference between lighting transformers and control transformers
In principle and construction, there is no difference between the two.The only difference is that the secondary coil output voltage is different.
How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
General digital multimeter has a capacitor (some of the files with a million capacitance test table of Jack, some use pen)
Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
The self winding transformer is connected by all its windings, and depends on the position of the sliding contacts to change the magnitude of the voltage. Therefore, there is not only a magnetic connection between the primary winding of the autotransformer (the power circuit) and the two winding (the power supply circuit), but also the direct connection of the circuit. It forms a circuit with the earth, so it can not be used as the power source of the safety voltage