XBD-DW series horizontal multi-stage single-suction fire pump
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Product overview
XBD series compared with previous fire pump, its with the pump outlet pressure differential between the reduced flow specification, minimum of only 0.05 MPa. The spectrum density increasing, the distribution is more reasonable, can better meet the needs of different floors and pipe resistance of fire control, meet the design selection. XBD series product is reached leading level, cover an area of an area small, light weight, low noise, good performance, the advantage of reliable running.
Application field
When the suitable operating mode
Flow range: 2.5 L, 200 L/S
Pressure range: 0.11-2.38 Mpa
Liquid temperature: 80 ℃ or less water
The working conditions
Low XBD series centrifugal fire pump can be divided into; Vertical single-stage, vertical multistage single export-oriented, horizontal multistage export-oriented, vertical multistage export-oriented, horizontal multistage export-oriented
Low XBD series centrifugal fire pump adopts copper alloy, copper alloy impeller pump shaft seal ring, stainless steel, ensure "at any time is up and running"
Low vertical/horizontal multi-stage export series satisfy the needs of high-rise building points to distinguish the pressure
Low horizontal multi-stage more export series intermediate exports may be two types of installation: vertical, horizontal direction
Low level at the end of the series vertical multistage exports more exports and export can be installed in four directions: middle inlet direction compared to 0, 90, 180 o, o o 270 o
Low horizontal multi-stage series is suitable for installation at a lower height of vertical space
- Q: What are the meanings of the vacuum pump, the front pump and the main pump?
- The main pump and the front pump with the general vacuum unitThe front pump can be understood as a mechanical pump. It can be used by itself, but the pumping rate or the vacuum can not meet the requirements. In this case, we add a booster pump
- Q: The difference between diaphragm pumps, vacuum pumps and centrifugal pumps
- The function of vacuum pump is to make vacuum, which has many kinds of structure, such as centrifugal, diaphragm (diaphragm), piston, liquid ring, rotary plate, jet type...................
- Q: There are second cutting, third cutting, why three times?
- So some pumps are written in the back of XXXX-125A or B, that is, the impeller nominal diameter is 125, A is through a cut, B is the 2 cutting. To reach the applicable conditions, only the calculation is not enough, but also after cutting to test to determine.
- Q: How to distinguish the flow and displacement in the hydraulic pump? What's the difference between the two?
- For example, once you sprinkle water from the tank to the ground, one shot of water is 1000 milliliters, which is equivalent to displacement, once (pump turn) 1000 ml.,
- Q: What is pump suction work?
- Pump is mainly used to transport liquid, including water, oil, acid and alkali liquid, emulsion, suspension emulsion and liquid metal, etc., also can transport liquid, gas mixture and liquid containing suspended solids.
- Q: What is the pump delivery? What's the difference between years and years?
- Secondly, the landlord asked the question, although I did not go to the insurance company to practice the operation, but to my four years of learning, as well as internship experience, or can help you analyze, and I hope to help you.Pay is a one-time payment of premium -- all wholesale D sea n
- Q: What is the function of the heating pump system for the water pump design?
- As the feed water temperature is higher, before starting, if not enough to warm the pump, the pump body temperature is uneven, there is a hot, cool phenomenon. The upper part is inflated and the lower part is inflated"
- Q: Working principle and structure of external gear pump
- External gear pump is the most widely used gear pump, the general gear pump usually refers to the external gear pump. Its structure as shown in the diagram, there are mainly driving gear, driven gear, pump body, pump cover and safety valve and so on. The seal space of pump body, pump cover and gear is the workshop of gear pump. The wheel shafts of the two gears are respectively arranged in the bearing holes on the two pump cover, and the driving gear shaft extends out of the pump body and is driven by the motor to rotate. The external gear pump is simple in structure, light in weight, low in cost, reliable in operation and wide in application. When the gear pump works, the driving wheel rotates with the motor and drives the driven wheel to rotate
- Q: Metering pumps related matters
- 2) change the metering pump diaphragmTrouble is often encountered when the old diaphragm is removed. Provide some additional advice on how to remove the old diaphragm.After in the pump head loose, remove the pump head before the stroke length adjustment to the 10% position. To ensure that the electromagnetic axis has sufficient pressure to maintain its connection firmly, so that you can unscrew the diaphragm.The pull end torque from the Jack out of the screw. Seize the liquid counter clockwise rotation. There is a slight resistance that can unscrew the diaphragm.Chemical 3 measurement may end in fluid crystallization, resulting in a one-way valve ball and seat valve does not work.In the end inhalation metering pump may have a gas leak. Hydraulic end suction side connector may lack O ring or suction valve connection loose.3) flow monitoring and measurement of a high viscosity medium, in the process of liquid delivery received a flow failure signal, how can we solve this problem?Move the hydraulic end by loosening the 4 pump head screws. Rotating stroke length to 10%, and seize the hydraulic end, and then slide out of the screw hole, then the screws do not touch them, but still control the back and diaphragm. Then rotate the component counter clockwise, with a slight resistance, and the diaphragm will loosen from the electromagnetic axis. If the diaphragm is not loose, use some grease on the contact surfaces of the diaphragm and the electromagnetic shaft. After a few minutes, gently tap the diaphragm with a small plastic hammer. Then proceed again in accordance with the above description.
- Q: How long does the fine stone pump need maintenance? What should I pay attention to?
- Check the line from the relief valve to the cylinder inlet to ensure that there is no external drainage or deformation due to impact and wear and that the connections are complete and fully tightened. - replace any damaged pipe immediately. - change the original settings strictly: all adjustments and calibrations can only be done by professionals. - no fucks hydraulic components, otherwise manufacturers on product warranties and liability shall not be responsible for. A warning because the hydraulic oil can reach very high temperature, there is the danger of burns, so open pipe fittings should take appropriate protective measures. Any replacement parts must conform to the level specified by the manufacturer. 8.2 check lubrication grease pump in oil at any time to ensure adequate and clean the lubrication pipeline joints without overflow phenomenon. Check the lubrication of the running parts at any time, and find the parts which lack oil, and check them immediately to prevent accidents. - check that the centralized lubrication system is effective daily. When the grease pump is empty, the grease added is often not easy to pump out because of the bubble. In this case, open the outlet of the pump, run the grease pump until the grease is re flowing, and then connect the pipe
Send your message to us
XBD-DW series horizontal multi-stage single-suction fire pump
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches