Stainless Steel Tie
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 500 Pieces pc
- Supply Capability:
- 10000 Bags per Day pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1.Features:
Unique multi-locking mechanism design on the ladder strip can be applied without crimping tools. Self-locking for fast, easy application.Extended ladder slot provides larger bundle diameter with the same length of tie.Large round slot at the tail-end allows application of hook-type tools.Uncoated tie for high temperature applications. Coated surface provides excellent
chemical and weathering resistance, and superior insulation and protection of cables.
2.Size:
Width:6.3mm and 9.5mm
Length:from 100mm to 1500 mm.
3.Packing:
100pc per polybag,carton for outer packing.
- Q:I got the machine, and then removed, there is a section of the tube was bent, and that position really need to fold before, because there is a turn, but now that place too hard, and completely unreasonable that he is normal Of the time, because the demolition of a little time will be folded, do not know that they may be deliberately? And then to add money, encounter this situation usually how to do more
- Single-core cable line grounding line commonly used grounding 1. shield one end directly grounded, the other end through the protective layer to protect the ground: When the line length of 500 --- 700m and below, the shield can be used directly to one end of the ground (cable terminal Position ground), the other end through the protective cover to ground. 2. shield the midpoint of the ground: When the line length of 1000 ---- 1400m, the use of midpoint grounding. in the middle of the line position, the shield directly grounded, the cable ends of the shield through the protective cover to ground. The middle ground is usually required to install a straight connector. Install an insulated connector at the midpoint of the line. The insulated connector disconnects the cable shield, and the shield is grounded through the protective cover, and the two cables are shielded and grounded directly. 3. Shielded cross-connect cable lines are very long (1000 --- 1400m above), you can use shield cross-connect. This method is divided into three equal parts of the length of the three or three times the number of segments, each section between the installation of insulation joints, insulation joints between the three-phase shield with a coaxial cable, cross-linked box for transposition, cross The interconnection box is provided with a set of protective protector, and the two sets of insulated connectors are arranged on the line.
- Q:How to properly remove air conditioning in the absence of electricity
- 1. Fluoride: then the external machine of the high-pressure valve (thin tube) with a hexagonal wrench, closed, about 1-2 minutes after the closure of low-pressure pipe (thick tube). 2. Remove the pipe: with a movable wrench to high and low pressure pipe copper screw unscrewed. 3. Remove the internal and external cables. Open a plastic cover outside the machine, cable terminal can be seen, with a screwdriver screw off, remove the cable. (Do the mark, so as to avoid the next installation to line) 4. The machine (hang up) off, attached to the pipeline out. (Note: If you do not install a long time, also need to transport, it is best to tie in the pipeline on the cable removed, find the pipe and the machine's connecting nut, with two wrenches, And then the pipe plate is good) 5. Remove the wall of the machine hanging plate. (Hang up) 6. Remove the external machine, with two wrenches, the external machine 4 feet screw off, if the rust die also use the grinding machine to wear off the foot screw
- Q:How does the geothermal switch above the sensor line pick up?
- Find the relevant units ah, such as the mining bureau ah, will be issued by the relevant acceptance report can be produced
- Q:How to connect the high voltage distribution cabinet twice
- . because the PVC trunking itself is very light, and easy to cut, so in addition to bulk cutting generally do not need mechanical cutting. . no pvc trunking 45 degrees angle of special tools, only do it yourself.
- Q:I would like to ask you friends, merchandise residential house inside the cable how to arrange, I saw in the weak box has a fiber optic cable home, that is, I do not know how to lay, I do not understand, I think you look, if the light cat and router can Placed in the weak box, the router from the router to the network assigned to each room, if the routing into the weak box will not be wireless signal attenuation, the younger brother is a novice, do not understand, please heroes branch try to jealousy Spring but Shanghai move, very grateful, no wealth value, I am sorry. More
- Do the map, you can, the key is the price is not good, the selected accessories are not very good, it is recommended to take several
- Q:What is the name of this plastic buckle? Since the US military used to replace handcuffs, it must be very strong, what is the plastic? More
- Is the nylon cable ties, but the quality of good points
- Q:What equipment does fiber engineering need? What are the brands?
- Do outdoor fiber engineering. Sure to have steel wire, cable hook. Tighten the wire. There are escalators. But also more than 6M bamboo ladder. Because the strand to be linked to the 6M high position can be. Into the room, it is very simple. Pigtails, fiber jumpers, fiber patch panels. Couplers and so on. And then spread out the fiber from the inside of the cabinet after the patch panel. Then fused. After a good tie with a good tie. It is best to use optical power meter test under the barrier. Whether the attenuation meets the standard.
- Q:Why do you want to use white cable ties in the communication room?
- Power of the election cable a little better, although the specification is not strong, but the general design will use cable
- Q:We bought the elevator dedicated cable, with video power wire, the customers say that they have done before the tie tie is not broken, is the elevator installation problem or they require bundled copper wire should not be used To tie There are several elevators that are now under the copper wire cut off more
- First look at a few circuits. There is a sketch before the cloth. Optimistic figure. From the electric box to open to wear the main line, and then sub-line on the wall. To clear every road. Lead wire with threader!
- Q:Will the power cord wiring with what is called, how the insulation effect
- . called the cable terminal, there is heat shrinkage, put it on, and then a baking guns, it is tightened wrapped in the wiring head. Can be waterproof, the best insulation effect. . the cable terminal set of waterproof, stress control, shielding, insulation in one, with good electrical performance and mechanical properties, in a variety of harsh environmental conditions for long-term use. With the advantages of light weight, easy installation and so on. Cable terminal is widely used in electric power, petrochemical, metallurgy, railway ports and construction and other fields. . casing, usually used in the construction of the basement, used to protect the pipeline or to facilitate the installation of iron pipe. Casing classification: rigid casing, flexible waterproof casing, steel pipe casing and metal casing and so on.
1. Manufacturer Overview |
|
---|---|
Location | Zhejiang, China |
Year Established | 2009 |
Annual Output Value | Below US$1 Million |
Main Markets | North America South America Eastern Europe Oceania Mid East Eastern Asia Western Europe |
Company Certifications | ISO 9001:2000 |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | ningbo,shanghai |
Export Percentage | 81% - 90% |
No.of Employees in Trade Department | 3-5 People |
Language Spoken: | English, Chinese |
b)Factory Information | |
Factory Size: | 3,000-5,000 square meters |
No. of Production Lines | 5 |
Contract Manufacturing | OEM Service Offered Buyer Label Offered |
Product Price Range | High and/or Average |
Send your message to us
Stainless Steel Tie
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 500 Pieces pc
- Supply Capability:
- 10000 Bags per Day pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords