• Spectacle Wear Plate 6''  for Jacon Concrete Pump System 1
  • Spectacle Wear Plate 6''  for Jacon Concrete Pump System 2
  • Spectacle Wear Plate 6''  for Jacon Concrete Pump System 3
Spectacle Wear Plate 6''  for Jacon Concrete Pump

Spectacle Wear Plate 6'' for Jacon Concrete Pump

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 pc
Supply Capability:
1000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Product Name: Spectacle Wear plate 6''  for Jacon Concrete Pump

1.        Specification 

Size6'', 8''
Materialtungsten carbide, Q235B steel, Vautid-150 electrode imported from Germany
Lifetime30,000-80,000cbm
Carbide HRA> 86
Electrode HRC> 63
Typehardfaced, tungsten carbide and 7 shape tungsten carbide
Applicationmud pump, shotcrete,trailer and truck mounted concrete pump

2.        Application

Spare parts for mud pump, shotcrete,trailer and truck mounted concrete pump

         3.  Package

Plastic bag and carton box, also according to your requirements

FAQ:

Q1: Why buy Materials & Equipment from OKorder.com?

A1: All products have its ISO certifications, adheres to the highest standards and a commitment to supply chain safety and customer satisfaction.

Q2: How do we guarantee the quality of our products?

A2: We have established an advanced quality management system which conducts strict quality tests at every step, from raw materials to the final product. At the same time, we provide extensive follow-up service assurances as required.

Q3: How soon can we receive the product after purchase?

A3: Within three days of placing an order, we will begin production. The specific shipping date is dependent upon international and government factors, but is typically 10 to 30 workdays.

Q4: If we can produce Spectacle Wear plate 6''  for Jacon Concrete Pump according to customers request?

A4: Yes, we can produce Spectacle Wear plate 6''  for Jacon Concrete Pump according to the difference country situations to make it suitable to the market and customers. We have very professional technical team to make the design.

Q5: How to make a quick resolution for after service?

A5: We have overseas branches all-around of world, If needed, the seller shall dispatch 2 engineers to the buyer's site for supervision of training. The buyer shall make available of necessary facilities &skilled personnel at site for training.

 

Images: 

 

 

Spectacle Wear Plate 6''  for Jacon Concrete PumpSpectacle Wear Plate 6''  for Jacon Concrete Pump

 

Spectacle Wear Plate 6''  for Jacon Concrete PumpSpectacle Wear Plate 6''  for Jacon Concrete Pump

 

Spectacle Wear Plate 6''  for Jacon Concrete PumpSpectacle Wear Plate 6''  for Jacon Concrete Pump


 


 


Q: The suction pump has a nominal suction range of 30 metersHow deep can a well be sucked?Well, sixteen meters,
Vacuum pump plus form must not reach a standard atmospheric pressure vacuum, so the general can absorb 8 meters is very good, and the self suction pump itself and loss, the horizontal self-priming pump can suck on basic 4~6 meters is very good, self-priming pump. Suction lift of 30 meters is purely in the Mongolian people, does not comply with the laws of nature, obvious anti science.
Q: Troubleshooting of diaphragm pump
In the application of the pump, these conditions are likely to encounter. Each situation can be divided into several possible reasons. This guide lists the causes of failures and gives appropriate corrective maintenance measures. The meaning of all the specific terms in the guide is listed later.Air valves - copper or stainless steel valves are bolted to the center of the pump by four bolts.The piston aluminum cylinder is enclosed in the air valve to control the gas flow.Cavitation - because the pump inlet for the amount of fluid to reduce or lack, the pump discharge is less than the amount of quantitative. In fact, the fluid chamber is full of fluid before it is discharged.Static pressure drop - the inlet pressure from the pump centerline to the free point - the inlet is measured in pounds, including the specific gravity and velocity of the fluid.
Q: What is the dry running protector of screw pump? What's the principle and function? Thank you
Principles are generally temperature sensing, such as: when the screw pump by air, the stator and rotor will be heated due to friction,
Q: What does "anti pump" mean in pump operation?
The pump again is the pump, the theory is the plugging problem can be solved, but if you are against the pump after pump has been plugging serious, and pump has been unable to solve the plugging problem, finally the worst solution is a split pipe, if the situation under enormous pressure will only exacerbate the plugging
Q: Water pump outlet valve sequence
In order to prevent the generation of water hammer when the pump stops the damage to the rubber head, should be immediately set rubber head pump outlet, the gate valve and the check valve is not a very convincing reason to decide the order of habits in our hospital order rubber head, check valve, gate valve1. Check valve located in front of the pump, I do not know what the significance is too great to think of.2. The actual installation sequence shall be: soft fittings, check valves, gate valves. The pressure gauge is best installed on the water outlet of the pump, but it must be in front of the check valve.Reason: 1) the soft joint is used to reduce vibration. The connection between the pump and the piping system, of course.2) normal work, the gate valve is not operating, and the check valve is frequent action, so the probability of maintenance is larger, when the maintenance of the pump closed, the water outlet valve can be maintained without affecting the normal operation of the system.3) the pressure gauge is installed in the check valve, which can prevent the impact and damage of water hammer on the pressure gauge.
Q: What is the "variable" of a variable pump? Is the displacement change or the flow change? Thank you
These two don't mean the same thing? That is, the pump outlet can be changed
Q: What is the lift off the dead center point? This is a straight mark about the water pump. What is the function and the relationship between the design head and the pump head? ThanksWhat exactly is the dead point lift? What's the function of this indicator?
Pump downstream equipment design pressure is greater than 3MPa, if it is 400 meters, the downstream equipment design pressure is greater than 4MPa
Q: What are the constant pressure pumps?
Constant pressure pump is also called the booster pump, the name is used for booster pump, its main purpose is water heater booster, with tall low pressure, sauna, bath and other pressure in the apartment, the lack of water pressure, solar automatic pressurization and so on.
Q: Water pump spoon pipe for power plantWhich hero can tell me what is the water pump spoon tube ah? And its role
Then control the speed level, to achieve the purpose of regulating the speed and flow of the feed water pump.
Q: What does "dual purpose" of water pump mean? Please expert advice
1, if the water pump in the process of a strong vibration, then must stop to check what is the cause, otherwise it will cause damage to the water pump.3, when the pump valve Water Leakage, some people will fill with dry soil to the water pump inlet pipe, the water washed in the end valve, this is indeed undesirable. Because when the dry soil into the inlet pipe, when the pump started to work, these dry soil will enter the pump, then it will damage the pump impeller and bearings, thus shortening the service life of the pump. When the valve Water Leakage must take to repair, if it is serious that need to replace the new.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords