Spectacle wear plate for Jacon concrete pump

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
1000sets per month pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Spectacle wear plate for Jacon concrete pump

1.Specifications:

Size6'', 8''
Materialtungsten carbide, Q235B steel, Vautid-150 electrode imported from Germany
Lifetime30,000-80,000cbm
Carbide HRA> 86
Electrode HRC> 63
Typehardfaced, tungsten carbide and 7 shape tungsten carbide
Applicationmud pump, shotcrete,trailer and truck mounted concrete pump
Manufacturer with competitive price


Leading manufacturer for all kinds of brand concrete pump wear plate, technical date as below


TechnologyTechnical StandardService LifeHardness
Atmosphere sintering processSY5064-855 times more than similar traditional productHRC>70
Tensile StrengthFracture Toughness valuesYield Strength
>1000Mpa10 Mpa1/2>1000Mpa
Substrate/Matrix MaterialBending StrengthHigh Temprature ResistanceSurface Roughness
45#,40Cr, 1Cr13 steel1100-1300 Mpa700-800 centigrade degreeRa<0.1
Bond StrengthCorrosion ResistanceCompactness
>110Mpa>95%Gas Hole Ratio<0.01%


2.Packing:

1. Outside package: standard export wooden case

2. Inside package: bubble bag


3. Why choose us?

1. Manufacturers with 8 year's experiences.


2. High quality, best price, prompt delivery.


3. Standard quality control system


4. Small orders are accepted.



Experience: 1. over 8 years concrete pump wear part’s experiences.

                     2. 4 years gold supplier on alibaba.

                     3. 2 years OEM.

Quality: 1. ISO9001 certification.

               2. Strictly quality control with every process.

               3 . Material: electrode imported from Germany. Q235B steel body.

               4. High performance.

               5. Advanced manufacturing equipment and leading technical.

Type: Different types with different lifetime.

          OEM, ODM is acceptable.

Service: Delivery: 7-10 days after receiving the money.

               MOQ: 1 set.

               Prompt attention must be paid to any requirement and inquiry.

Price: Different price with different types,

we are faithfully that our price can help you beat your competitor with the same type product.


We are leading manufacturer for concrete pump wear plate, S valve and other wear parts in the hopper for more than 8 years, with high quality and competitive price, all kinds of brand you can find from us, such as PM, Schwing, Sany, Zoomlion, Cifa, Sermac, IHI, Niigata, Mitsubishi, Kyokuto, KCP, Jacon, Elba...etc.  

OEM service is available, products can be produced as buyer's drawing or samples.

At the same time, we also sell following parts with good quality and competitve price:


1. Concrete pump clamp in casted and forged

2. Concrete pump rubber hose

3. Delivery pipe and elbow

4. Piston

5. Sponge ball

6. Delivery cylinder

7. Plunger cylinder


Any questions, I am Hilary here. feel free to contact me.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to install, operate and maintain the pipeline booster pump?
Should be "People's Republic of China network security law" requirements, since June 1, 2017, the use of Internet services to carry out real name authentication account. In order to ensure your Baidu account can be used normally, please check the account number as soon as possible. Thank you for your understanding and support.How to install, operate and maintain the pipeline booster pump?Brother Yao s Gc76 2547 | browseRecommended for 2016-12-01 23:52:54 best answerThe installation of booster pump must be installed horizontally or vertically according to the installation method. The direction of flow shall be consistent with the arrow on the pump body, and installed as far away from the water level as possible. A valve shall be installed on the pump inlet line for ease of use and maintenance. When the impeller is the aspiration level below the pump on the pump shaft end or around the pump should be installed check valve, the outlet is connected with 13 links for water use, at first use to pump should be filled with water, and tighten the screw plug. The pipe connection should be tight, especially the water inlet pipe can not leak, otherwise it will reduce the pump head or not pumping water. The pump cavity is not water, not a long time running, so as not to damage the seal
Q:Direct connection pump What is straight pump and non direct pump? What's the difference in structure?
What is straight pump and non direct pump? Direct coupled pump shaft and the motor shaft is directly coupled with the coupling and non direct coupled pump: pump shaft and motor shaft through the belt pulley, V-belt connection or other forms of transmission. What is the difference in the structure: the direct coupled pump has the advantages of compact structure, simple installation, but the relatively small power; non direct coupled pump: pump and motor is independent, the two transfer torque through the belt, the structure is relatively large, complex installation, general power is relatively large.
Q:Is the diaphragm pump and the drain pump one?
First of all, there's something wrong with your concept.Diaphragm pump is in accordance with the way the pump classification, drain pump is in accordance with the use of pumps classification.
Q:Concrete pump 125 pipe wall thickness
Concrete pump diameter 125mm, pipe wall thickness is generally 4mm, also have 4.25mm, 4.5mm, 4.75mm, need to be in accordance with the rules of transport.
Q:Any center of the pump
Looking forAlignment means the position of the center of rotation of the pump and motor so that they are in the same line.At least three times after the initial installation or after installation:
Q:What are the uses and precautions of magnetic pumps?
Notice of use:1. prevent particles from enteringHas the ferromagnetic impurities and particles into the magnetic actuator and bearing friction is not allowed.The transport of crystallization or precipitation of the medium to the flushing (after pumping water, poured into the pump cavity drained after running 1min), in order to ensure the service life of bearing.The transport medium containing solid particles, the pump flow tube inlet filter.
Q:Difference between pump and compressor
Working principle:The impeller is installed in the pump casing and is fastened on the pump shaft 3, and the pump shaft is directly driven by the motor. There is a liquid suction in the center of the pump shell, and 4 is connected with the suction pipe 5. The liquid through the bottom valve 6 and the suction tube into the pump.The liquid discharge port 8 on the pump housing is connected with the discharge pipe 9. Before the pump starts, the pump shell is filled with the liquid to be transported; after starting, the impeller is driven by the shaft to rotate at high speed, and the liquid between the blades must also rotate. Under the influence of centrifugal force, the liquid is thrown from the center of the impeller to the outer edge and obtains energy, and leaves the outer edge of the impeller at high speed to enter the volute pump shell.
Q:Is vane pump good or gear pump good?
The main working parts of vane pump is provided with a plurality of sliding vane rotor, when the rotor rotates, the eccentric configuration of stator cavity contour or rotor, blade sliding slot in leaves due to volume changes, resulting in the suction effect. The similarities are: 1, rotary type positive displacement pump has self-priming ability, but are not allowed to do; 2, with continuous flow pulsation, but also have flow and pressure; 3, the theory of flow is determined by the working parts of the size and speed, has nothing to do with discharge pressure; 4, rated discharge size, pressure and working parts mainly depends on the pump speed is independent of the sealing parts and bearing capacity; differences: 1) gear pump structure is more simple, reliable, low price; vane pump has complicated structure and high manufacturing precision parts, the blade is easy to get stuck, more sensitive to the oil clean degree and viscosity.
Q:What is cavitation, centrifugal pump cavitation phenomenon how to solve?
Centrifugal pump cavitation phenomenon how to solve?:Measures to improve cavitation resistance of centrifugal pumps(1) improve the design of the suction port of the centrifugal pump to the impeller. Increase flow area; the radius of curvature increases the impeller cover inlet section, reduce the flow accelerated sharply with pressure; reduce the thickness of the blade, and the blade inlet rounded, close to the streamline, can also reduce the acceleration and pressure flow around the blade head portion of the impeller and the blade inlet part; improve surface finish in order to reduce the resistance loss; the blade inlet edge extends to the impeller inlet, the liquid flow in advance to accept work pressure, improve.
Q:What's the difference between a concrete pump and a concrete pump truck?
Concrete pump and concrete pump truck are concrete conveying machinery, use the same, but the former need to transport and car towing need additional support pipeline, the locomotive body and arm extends freely, without pipeline, hundreds of thousands of millions of the former, the latter

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range