• Solar Battery REX Series for Solar and Wind Power REX-500 System 1
  • Solar Battery REX Series for Solar and Wind Power REX-500 System 2
  • Solar Battery REX Series for Solar and Wind Power REX-500 System 3
  • Solar Battery REX Series for Solar and Wind Power REX-500 System 4
  • Solar Battery REX Series for Solar and Wind Power REX-500 System 5
  • Solar Battery REX Series for Solar and Wind Power REX-500 System 6
Solar Battery REX Series for Solar and Wind Power REX-500

Solar Battery REX Series for Solar and Wind Power REX-500

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1000 unit
Supply Capability:
5000000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Solar Battery REX Series Introduction

REX battery  is designed for Renewable Energy Sources such as  Solar and Wind Power. REX protects  our environment using Green Technology and  benefits the World's Urban  and Rural Population by Generating  Power Economically from a Clean Source  of Energy.

REX is a product developed  by our R&D with  an " eXtra" in Performance  and Life Span.
The REX series batteries are ensured the quality with  QA  system according to the ISO9001&ISO14001 standard.

 

Solar Battery REX Series for Solar and Wind Power REX-500

Solar Battery REX Series for Solar and Wind Power REX-500

Solar Battery REX Series for Solar and Wind Power REX-500

Solar Battery REX Series Features and Benefits

  • Long life design for both  cyclic and float applications

  • Superb security and  reliability

  • Robust design inside and out

  • Excellent deep discharge  recovery fast recharge performance

  • Extra long back-up times

  • More cost effective than  nearest equivalent


Type:

  REX-500

Voltage:

  2V

Nominal Capacity:

  500Ah(C10)  500Ah(10 hours rate:)

Length:

  231mm

Width:

  155mm

Height:

  396mm

Height   with termial:

  408mm

Weight:

  39.5Kg

Solar Battery REX Series Compliant  Standards

  • IEC60896-21/22

  • IEC61427

  • BS6290 part 4

  • Telcordia SR4228

  • Eurobat guide

  • UL

  • Manufactured under system  ISO9001(TUV) and ISO14001

Solar Battery REX Series  Battery  Installation Compliant with

  • EN 50272-2 or local  equivalents

Solar Battery REX Series Main  Applications

  • Renewable energy source such  as solar and wind power

  • Telecom exchange and transmission  system

  • Mobile communication system

  • Power plant and power  transformer system

  • Navigation aid signaling  system

  • Radio and broadcasting  station

  • Emergency lighting system

  • Other standby, cyclic system

Solar Battery REX Series Installation  and Operation

  • Recommended float charge voltage  2.27V per cell at 25oC
     compensation in function of temperature -3mV/oC/cell

  • Cycle and equalize charge  voltage: 2.35V per cell at 25oC
     compensation in function of temperature -5mV/oC/cell

  • CC-CV charge current  unlimited, otherwise 150A  max. if T>25oC

  • Preferred operating  temperature range 15oC to 25oC(68oF to 77oF)

  • Maximum operating  temperature range -40oC to 50oC(-40oF to 122oF)

  • A separate battery room is  not necessary

  • Reduced maintenance no water  addition required.

  • Design float life: 20 years at 25oC (77oF)

Solar Battery REX Series Construction

  • Positive plate --- Reinforced grids in a corrosion-resistant pure  lead, high tin, low calcium alloy

  • Negative plate --- Lead-calcium alloy grid

  • Separator ---  High  density microporous glass mat with low electrical resistance

  • Container & lid --- High strength ABS(HB). Optional flame retardant F V-0 and halogen-free versions available

  • Electrolyte --- Sulphuric acid with a density of 1.28g/ml  absorbed in AGM

  • Terminal design --- Patented leak resistant seal configuration with  brass insert

  • Safety valve --- Calibrated opening pressure , the valve  equipped with flame arrestors for  increased operational safety and service life.

 FAQ

How long a battery can last?

The service design life of a battery are vary considerably with how it is used, how it is maintained and charged, temperature, and other factors.

Do batteries self-discharge when not in use?

All batteries, regardless of their chemistry, self-discharge. The rate of self-discharge depends both on the type of battery and the storage temperature the batteries are exposed to. However, for a good estimate, Narada batteries self-discharge approximately 4% per week at 80ĄăF.

What is battery cycle life?

One cycle of a battery is a discharge from full charge to full discharge and a return to full charge again. The total number of cycles a battery can perform before failure is called its Cycle Life. Moat battery manufacturers will not discus the Cycle Life of their product. Many advertised Deep Cycle batteries have not been tested, or, which is the case with cranking batteries, were never designed for long Cycle Life .

 

Q:What is a maintenanceable battery?
Maintenance-free battery due to its own structure on the advantages of electrolyte consumption is very small, in the life of the basic need not add distilled water.
Q:How to determine the battery is good or bad?
Instrument test: the general use of battery discharge tester, the test instrument two positive and negative clamp were holding the battery positive and negative electrodes, press the test button to observe the test instrument instructions.
Q:How does battery activation work?
Always keep the battery surface clean. Found that the surface of dust and acid, it should be timely wipe, wipe can be wiped with soda water wipes wipe again, after rinse with water.
Q:What is the difference between a maintenance-free battery and a conventional battery?
As a result of maintenance-free batteries using lead-calcium alloy grille, the amount of water generated when charging less water evaporation, coupled with the shell with a sealed structure, the release of sulfuric acid gas is also very small, so it compared with the traditional battery, With no need to add any liquid, the wiring pile head, wire and body corrosion less anti-overcharge capacity, starting current, power storage time is long, by the car people welcome.
Q:What is the meaning of the battery above 12v65Ah?
12V is said to be the voltage, 65Ah is the current. (A is the unit of current. H is the time unit .1 hours.)
Q:How does the battery increase the voltage?
Chemical energy can be converted into electrical energy device called chemical battery, generally referred to as the battery. After discharge, the internal active material can be regenerated by charging - the electrical energy stored as chemical energy; chemical energy can be converted to electrical energy again when the discharge is required. This type of battery is called a battery (Storage Battery), also known as secondary battery.
Q:How to repair the battery?
Pry open the adhesive or heat-sealed battery cover, reveal the maintenance-free battery rubber exhaust valve, carefully remove the exhaust valve, save, observe the battery internal situation. Add 0.1% to 0.5% of the electrolyte to the battery, just to the battery above the flow of electrolyte. At the same time, check whether the black impurities, if there are obvious black turbid impurities, indicating that the battery plate has been significantly softened, the possibility of battery repair is relatively small. If there is no black muddy impurities, need to wait 4 hours later, the water fully into the battery. If it is only because the deactivation time is long and cause the battery capacity to decline, do not need to carry out this step operation, should go directly to step 3 pre-charge.
Q:What are the advantages of maintenance-free batteries?
The advantage of a maintenance-free battery is that the service life is twice as long as the dry battery! And in the use of the process without maintenance! The voltage is also relatively stable.
Q:How should the battery be well maintained?
Voltage check the state of the battery standard voltage should be maintained between 12.2 ~ 12.7V. If the voltage is too low should be charged, the charge should be kept small charge for a long time. Battery charging need to use a professional charger, the owner will not try to charge their own, the owner can only keep the engine running on the battery can be charged. If the battery aging should be replaced.
Q:Lead-acid battery how to maintain?
When receiving the battery should first check whether the phenomenon of short circuit, first short circuit repair and then fill the distilled water.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords