Product Description:

Quick Details

  • Place of Origin: Jiangsu, China (Mainland)

  • Model Number: LCPA150-12

  • Usage: UPS

  • Voltage: 12v

  • Sealed Type: Sealed

  • Maintenance Type: Free

  • Size: 532*207*240(mm)

  • Weight: 47±0.5KG

  • Nominal Capacity: 150AH

  • Model: 12V150AH

  • size: 532*207*240(mm)

  • Nominal Capacity: 150AH

  • 100%DOD: 572times

  • 50%DOD: 1485times

  • 30%DOD: 2406times

  • self-discharge: <3%/month

  • packing: carton and plywood made in china

  • use: 12v battery

  • mode: 12v battery

Packaging & Delivery

Packaging Details:the packing of battery carton and plywood packing or recording to our clients' demand.
Delivery Detail:15-20 weekdays after receiving the deposit

Specifications

Toyo AGM VRLA deep cycle 12V 150AH lead-acid battery 
1)Germany material 
2)ce,ul,msds ,cgc,tlc 
3)export experience 15 years 
 


Battery Features:


1.The whole series are medium size sealed battery.

2.Long service life; designed life is six years.

3.Positive grid is thickened type.

4.Anode and cathode wrapping technology shall be adopted.

5.CW-M-101 sealant shall be adopted and it has the characteristics of good air-tightness, anti-vibration and corrosion resistance.

6.Calcium base hexabasic alloy particularly owned by the enterprise and scientific direction shall be adopted.

7.Proprietary formula of electrolytic solution shall guarantee excellent charge acceptance.

8.Japanese original additives shall guarantee excellent recovery capacity of battery after discharge.

5.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is a maintenanceable battery?
Maintenance-free battery due to its own structure on the advantages of electrolyte consumption is very small, in the life of the basic need not add distilled water.
Q:How to repair the battery?
To the battery in accordance with the 0.1C current discharge, record the discharge time. Its discharge current multiplied by the number of hours of time, is the battery repair capacity. If the Chongqing battery capacity to reach the nominal capacity of more than 70%, the end of the repair.
Q:How does battery activation work?
Always keep the battery surface clean. Found that the surface of dust and acid, it should be timely wipe, wipe can be wiped with soda water wipes wipe again, after rinse with water.
Q:How is the capacity of the battery defined?
100AH capacity of the battery, fully charged after the 100A current discharge can be an hour to put the power finished. 50A current is 2 hours put away! 20A is 5 hours! Of course this is the theoretical value, in fact it is impossible to have a constant current discharge.
Q:What is the difference between a maintenance-free battery and a conventional battery?
Different materials will produce a different phenomenon: the traditional battery in the course of the use of the phenomenon of liquid reduction occurs, because the antimony on the grid will pollute the sponge on the negative plate of pure lead, weakened after the full charge of the battery Electromotive force, resulting in excessive decomposition of water, a large number of oxygen and hydrogen, respectively, from the positive and negative plates to escape, so that the electrolyte reduced. With calcium instead of antimony, you can change the fully charged battery back electromotive force, reduce the overcharge current, liquid gasification rate decreases, thereby reducing the loss of electrolyte.
Q:The role of the battery?
Battery is a kind of battery, its role is to be able to save the limited power, in the right place to make 6v4ah emergency light battery. Its working principle is to convert chemical energy into electricity.
Q:How to determine the battery is good or bad?
General side maintenance has an observation hole if it is green to prove that the battery is normal if it is black to prove that the battery does not save electricity. There is to observe whether there is liquid exudation, if any, proved to be bad. Finally, you can touch the hand, such as feeling the battery around the plane has proved proof bad.
Q:What are the technical parameters of the battery?
Usually the capacity of the power supply is expressed by kV · A or kW. However, as a power supply VRLA battery, the use of security (A · h) that its capacity is more accurate.
Q:What are the hazards of battery over discharge?
Crystalline conductivity is poor, and bulky, will clog the pores of the battery plate, affecting the battery electrolyte penetration and exchange, but also further increase the battery resistance, a long time will prevent the battery power and chemical energy Of the reversible conversion, resulting in poor recovery of the battery charge, the battery was seriously damaged, or even unable to repair until scrapped.
Q:How to deal with waste batteries?
The old battery is ground and then sent to the furnace for heating, then the volatile mercury can be extracted, the temperature is higher when the zinc is also evaporated, it is also precious metals. Iron and manganese fusion after the steel to become the required ferromanganese alloy.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range