Production Introduction for Single Core LSZH material Insulated Fire retardant Cable 450 /750 V:
Voltage Rate: 300/500V, 450/750V
Range of Nominal cross section: 0.75 mm2 ~ 630 mm2
Conductor: Class 1/2 Plain annealed copper wires, solid or stranded
Constructions Insulation: XLPE or LSZH material
Core color: Brown, Grey, Black, Blue, Green/Yellow or others on request
Max. Operating Temperature: 70 ℃ , can be 90 ℃ ,105 ℃ and 125 ℃ as per
requirement
Packing: 100 meter/roll or as per requirement
Application for Single Core LSZH material Insulated Fire retardant Cable 450 /750 V:
These cables is with features of fire retardant, low smoking and halogen free, it is applied to fixed installing with heat resistance requirement of the places with a special demands of flame retardancy, the density of smoke emission and toxic index if the cable is burnt, such as subway, tunnel, nuclear power station, etc.
Production Standard for Single Core LSZH material Insulated Fire retardant Cable 450 /750 V:
I EC 60332, IEC 61034, IEC 60754, BS 7211 , HD 22.9, VDE0282, GB/T19666
The Feature for Single Core LSZH material Insulated Fire retardant Cable 450 /750 V:
The cable can be of flame retardance, fire resistance and other property
Packing photo for Single Core LSZH material Insulated Fire retardant Cable 450 /750 V:
FAQ For Single Core LSZH material Insulated Fire retardant Cable 450 /750 V:
Q1:What is the Production Capacity for your factory?
About 80 kilometer every day
Q2: What is the Minimum Order Quantity For Single Core PVC Insulated Cable 450 /750 V?
MOQ: 10000 meters for small size, 5000 meters for middle size, 1000 meters for big size
Q3:What is the delivery time for these cables?
10~15 working days
Q4: What standards is the product complying with?
We can produce thousands of electric wires and power cables complying with different standards, such as: GB, JB , IEC, BS, AS/NZS, VDE, UL ETC.
- Q: I have had my ASUS laptop for just over 2 months, and I've realised the power cable whilst being securely in, and charging without a problem, feels slightly loose when wobbled. I know this isn't a problem at the moment, but is this right, should it feel slightly loose? It moves quite freely inside the socket of the laptop when moved
- Same here. it shouldnt be a problem. if it is, bring it back to the shop.
- Q: This type of cable with the armor without expert advice, thank you. More
- Is there a problem driver in Device Manager? Should be driven by the problem
- Q: I'm gonna be running a 2,700watts RMS system on a Power Acoustik 4,500watt Class D Monoblock amp at 1-ohm. I have a 2005 Impala LS do I'm going to need a secondary battery. What size should it be? Also what size power wire and ground wire should I use? I'm going to be using 8gauge speaker wire. Any help is appreciated. Thanks!
- You can try the dealer for the exact cables for your vehicle, if they are not obsolete and are still available, no modifications required. But if shopping for aftermarket cables, longer may be better. You can always tie the extra cable up out of the way. If you start with a cable that is too short, you can't make it any longer. You want to make sure that the cables are not touching any hot engine parts, or crossing any sensitive wiring harnesses where electromagnetic fields could screw with electronic components. It may be better to let the local repair shop replace them for you.
- Q: So i'm trying to start up an old windows 98 model. I was thinking of using the cable from a laptop because it fits into the power supply. Problem is i don't know if its safe, advice?. On the computer it says quot;AC input: 115V~/230V~,10/5A 60/50HZON the power cable on the other hand, it says 16A 250VAm i good to go?
- Both the 250v and the 15A are higher than the computer will need / be consuming So it is safe to use.
- Q: My hard drive uses 15-pin SATA power connectorMY new power supply doesn't have this cable but instead it has 4 pin molex connector for the hard drive15-pin SATA power connector has 5 wires with these colors and order (white-black-red-black-orange)4 pin molex colors are (red-black-black-yellow)I want to use 15-pin 'connection head' from the broken power supply but as I said it has 5 wires while my new power supply gives me 4 wires!!!!! how to connect 4 wires to five wires head??? one wire has to be canceled i guess but which one?
- You got the wrong power supply. Get an IDE to Sata power adapter.
- Q: Hi,I have just bought a jasper xbox and i know this as it says ''12V, 12,1A'' on the back yet my power cable says ''12V, 16,5A''.I thought that the jasper xbox requires a specific power connector which wont fit the other types. Mine seems to fit fine, so have i got something wrong here? Cheers
- i don't know if somethings wrong with your xbox or power brick but i can tell u tho, if u use a Xenon power brick (12V,16,5A) on a jasper xbox u will run into a problem later on, for it will overheat and the CPU and GPU will warp and pull there self away from the motherboard, if u have ever heard of the towel trick( wrapping your xbox in a towel so it will overheat and the solder will pool up and re-solder the CPU/GPU back in place) that's where it come from, i would buy a jasper power brick if i were u (12V, 12,1A).
- Q: The power cable to my mom's laptop keeps making a buzzing sound that I've never heard it make. I've asked my dad, but he said it was normal. I was relieved until the cable made that noise after I unplugged it. What can it be? It is the power cable itself not the laptop.
- The buzzing noise is not that of a Laptop its rather that of the Power adapter of the Laptop so there is nothing to worry about it you laptop is as good as it can be. But i would suggest not to use that adapter for a longer time because it may cause trouble in voltage fluctuations .
- Q: Hello, I am looking to purchase a single power connector for 5 hard drives. I have a modular 1200W power supply, and all i can find on website is these single power connecters that do not even look like they will connect to my power supply. My computer came with power connectors for 4 hard drives in single cables. I do not want to waste another Power supply slot for just 1 more hard drive. Can anybody tell me how to search for this? Thank you.
- I do not want to waste another Power supply slot for just 1 more hard drive. That's what they're there for.
- Q: There is no load in the middle of the problem added: the laying of the laying, and now the longest cable can do more long
- Pipe protection cable to wear metal hose, metal hose and galvanized pipe to use metal lock connection, the connection can not pull the light pull on the line. If there is no metal hose or no metal lock, in the pipe when the pipe toward the cable to the appropriate bending, preferably in the mouth of the cushion cable skin, and then use the electrical adhesive tape sticky, sticky. After the nozzle cut with a polisher smooth grinding, the provincial scratch cable.
- Q: I just finished building my shed, I put a 1 1/2 inch conduit under the shed coming up into the corner. I am now about to dig the 65 foot trench back to the house. I need to run power, not a problem. I want to run a phone line, a network cable, and a cable wire for my satellite. I say shed but it is 12 by 20 feet with an attic. Can I run these additional lines in with the power. I was thinking about using a run of Shielded cables for the network and one for the phone. For the cable some heavy duty quot;I don't know what thoughquot;. Will the power lines mess the data up on them? What will work for the three if any. If I need to I could run them in a new conduit, but that is not cheap!
- First, contact the diggers hotline and let them know when you will be digging. They will come out and mark any buried lines with flags. Run the electrical in the proper, approved conduit (to code). Run the phone line in its own conduit. The network and satellite run together in their proper conduit. A few bucks extra is worth it when you realize that the interference on the television is caused by running them all together. Right?
Send your message to us
Single Core LSZH material Insulated Fire retardant Cable 450 /750 VH07Z-U
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 m
- Supply Capability:
- 30000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches