• Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable 300/500V System 1
  • Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable 300/500V System 2
  • Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable 300/500V System 3
Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable 300/500V

Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable 300/500V

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1000 m
Supply Capability:
30000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable

Production Introduction for Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable:


Voltage Rate: 300/500V, 450/750V

Cores: 1~7 cores

Range of Nominal cross section: 0.50 mm2 ~ 120 mm2

Conductor: Class 5 fine annealed copper wires or tinned copper wires

Constructions:Insulation: XLPE or LSZH compound

           Sheath: LSZH compound

Core color: Brown, Grey, Black, Blue, Green/Yellow or others on request

Packing: 100 meter/roll for small size, wooden drum for big size, or as per requirement

Max. Operating Temperature: 90 ℃ , can be 105 ℃ ,110 ℃ and 125 ℃ as per

Application for Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable :

The wires are flexible conductors used for the stranding of electric switchboards or lighting

systems, etc, they are particularly recommended where fire risks are important, and for public

installations or closed areas, also fit sensible buildings such as datas and electronic rooms.

 

Production Standard for Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable:

IEC 60227, BS6500, VDE0281, GB/T 5023, JB/T8734

 

The  Feature for Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable:

The cable can be of flame retardance, fire resistance and other property

 

Packing photo for Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable:



Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable 300/500V

Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable 300/500V

FAQ For Single Core fire retardant LSZH compound Insulated and sheathed Flexible Cable :

 

Q1:What is the Production Capacity for your factory?

About100 kilometer every day

 

Q2: What is the Minimum Order Quantity For Single Core PVC Insulated Cable 450 /750 V?

MOQ: 10000 meters for small size, 5000 meters for middle size, 1000 meters for big size

 

Q3:What is the delivery time for these cables?

10~15 working days

 

Q4: What standards is the product complying with?

    We can produce thousands of electric wires and power cables complying with different standards, such as: GB, JB , IEC, BS, AS/NZS, VDE, UL ETC.


 

Q4: What standards is the product complying with?

    We can produce thousands of electric wires and power cables complying with different standards, such as: GB, JB , IEC, BS, AS/NZS, VDE, UL ETC.



Q:It wont do any damage will it?
yes you can and it will be fine, my 8 pin connectors had clips on the end so i could remove 2 pins and use it as a 6 pin...
Q:i have geforce 210 and i absolutly don't like it :#92; i want something that doesn't need a power cable or something that can be powered by my 600w regular powersupply...THX!
What do you mean by power cable, it doesnt really matter, its in your case anyway and the 600W is enough to power most decent GPUs for a budget go for a AMD HD 6850/6870, a bit higher go for a GTX 560 TI or AMD HD 7870.
Q:so my old psu fryed itself, and i just ordered a new one, i have another psu that i can use but its only 350 watts, it has no gpu connector, can i still use my computer without the power for the gpu, i have no onboard video and i have a radeon hd 6850 256 bit gddr5. and my cpu is a amd phenom 2 x6 (six core) 1045tthankyou
..... aaaand how did you expect to power your GPU then?
Q:How high voltage armored power cable is grounded
Copper braided wire for cable and shielding lead wire. Stripped of the core of the copper shield with the outer layer of the plastic belt, the shield copper belt polished smooth, with electric iron, solder braided copper braid were welded in the three core copper shield tape. And then use the emery cloth polished armored steel strip welding area, with a soft copper wire and copper shield belt tied with three armored steel, and then use electric iron, solder braided copper braided with armored steel belt. In the sealed ground to fill the braided wire with solder to form a moisture-proof section.
Q:in the specs it says the power supply doesn't have a pci-e connector?Does that mean i cant use the video card, or is there a way I dont know? Please help.Thank you very much
Okay, right off the bat I see a problem with that power supply. Aside from not having a pci-e connection it states it doesn't work with SLI or Crossfire (i.e. Nvidia or ATI). Since you're wanting to get a GeForce card, which works with a mobo with an Nvidia chipset, you'd need a more up-to-date power supply. Second - that card uses 18 amps on the 12-volt rail, and according to the specs on that power supply it runs up to 16 or 17 amps, so the power supply you're looking at isn't powerful enough to support the card. My advice - first make sure your mobo has an Nvidia Chipset. Second, spend a bit more and get a better power supply, and check the voltage - you need at least 18 amps on the 12-volt for that card.
Q:trying to install new amplifier; running cable from battery through firewall to the trunk; done on several cars before; looking for advice or best practices...
if you look under the hood, facing the cars windshield, the far right corner against the firewall, there's a dip in the sheet metal. if you drill there at the lowest point, the hole will come out behind and a little above your brake pedal. run it through there , under the side trim. not only will this seperate power from rca wires (eliminating ground noise) but it will be easy to run. if you want a professional job, take out your seats (all of em) and run it under the carpet, but i'm sure you have to remove the center console. my buddy ran the wire under the car and drilled through the floor and ran it under the rug but that is such a bad idea because if the wire corrodes from weather you will have a fire.
Q:Power Cable Check Well b-type covers show what?
A grade steel fiber concrete inspection covers are used for airports or special roads and venues for expressways that can take off and land for helicopters
Q:Like from a computer monitor?or a pc power cable?would a generic power cable work for it or would it like, blow the brick up lol?
I asked an electrical engineer friend this same question, and I'm using my original launch 3 prong cable with a new official 203w xbox power brick with 2 prong input and he said it's totally fine. I've been using it for about a week.
Q:I want to put a poe switch into the patch panel and power a few runs throughout the office. Can the end users use the drop as a standard way to plug into a computer or add a switch if they need to split the internet? What if they want to add their own POE switch at the end of the drop?I can't beleive I haven't seen this question asked already! Anywhere on the intternet!thanks for answering
Yes, you can attach PoE or non PoE devices to the switchports. No worries. If a device is not configured for PoE, than it won't use it.
Q:I bought one on OKorder and thought it was just a regular outlet power extension but it's not.. what is it used for? 10 points
so okorder /

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products