PVC Trunking
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 2000 Meters m
- Supply Capability:
- 50000 Meters per Month m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1.this plastic parts are use for the circuit protection
2.meterial:UPVC
3.Extruded PVC
3.delivery: according to quantity
4.packaging : peper carton or according to customers specifications
5.We can manufacture as per customers' specification
( our productively of everyday is about 2000 meters.)
Our company specializes in the manufacturer of plastic products including sealing strips,weather strips,magnetic strips,board,pipes,PVC trunkings,decoration strips and lampshades of products using PVC,ABS,PC,PMMA and other materials.
We look forward to establishing business relationships with you.if you are interested in any of our products,please feel free to contact us.
- Q: 1. New to buy a house, there is a root threading machine developers did not wear a cable, from the weak box to the living room box, is due to need to be in this 1 tube to wear two cable, easy to wear? 2. From the weak box to the living room line box length of 8 meters, the cable about how long? Would you please understand someone? More
- It is recommended to use a low-smoke halogen-free screw. Reason: wire and cable extrusion equipment is the main component of the screw, it is related to the scope of the extruder and production efficiency, in order to meet the needs of different plastic processing, there are many types of screw. Low smoke halogen-free flame retardant cable material contains high-filled magnesium hydroxide or aluminum hydroxide, so the choice of the screw for the general use of ordinary type screw and its compression ratio can not be too large, generally 1: 1 ~ 1 : 2.5 between the more appropriate. the extrusion process also has an impact on the low-smoke halogen-free cable material out of the important single-purpose toilet to help solve the problem, that is the extruder cooling device, because the low smoke halogen-free material special Sex, in the extrusion process, due to friction and produce large heat, which requires extrusion equipment to have a good cooling device in order to control the process temperature. This is a problem that can not be ignored, if the temperature is too high will make the cable surface has a large pores, the temperature is too low will make the machine's machine current increases, easy to damage the device.
- Q: My house's wire, outside the line, the old building, about ten centimeters away, no threading, directly wiped in the cement, the new line, I would like to know do not have to wait for the cement and then closing the electricity, otherwise there will be problems , In a wire directly put in the cement need to pay attention to what? Questions added: I said to use copper wire they say are installed more aluminum
- Composite epoxy composite cable tray under normal circumstances choose green color. Bright and beautiful. Now there are manufacturers choose white color. Clean air, my name is my company's name, our company's website has a cable bridge picture. You can look at yourself. The general implementation of the standard using JB / T now we use their own corporate standards JZCY2011-01
- Q: Can the wire pipe be buried directly under the tiles in the decoration process?
- Coaxial cable Fine cable laying should not be twisted; b. The radius of the cable should be greater than 20cm; c. Installed in the cable on the work of the distance between the work sites should be greater than 05 meters; d. The installation of the cable connector should be reliable, and should prevent the signal from short circuit; Fine cable alignment should be in the cable slot to prevent damage to the cable; f. When laying the cable, do not pull hard to prevent the pull off; A section of the cable should be less than 183 meters, 183 meters within the two sections of cable can generally be used "T" head lengthened; h. Both ends must be installed terminal device, each at least one terminal to ground; i. Coaxial cable can not be installed in the outdoor, installed in the outdoor part of the casing should be installed. Twisted pair Twisted pair in the corridor and indoor alignment should be in the cable slot, should be straight alignment; b. Workstation to hub twisted pair of the longest distance of 100 meters, more than 100 meters available twisted pair connector to lengthen; c. Twisted wire in the machine room to be bundled into the line line, the alignment must have some rules, not chaos; d. Twisted pair at both ends to indicate the number, easy to understand the node and Hub interface corresponding relationship; e. Twisted pair should be firmly inserted into the hub and workstation network card; f. When the node is not used, do not unplug the twisted pair, it does not affect other nodes work; Twisted pair is generally not installed in the outdoors, a small part of the installation in the outdoors, installed in the outdoor part of the casing should be installed; h. Use eight core twisted pair, install their own joints, the eight lines should be installed, do not just install four lines, cut the other four lines.
- Q: Home decoration threading with what kind of good?
- Own home decoration of the Well. The Electric to do a little better, but also some security. The Upstairs said PVC threading pipe. The It's up. The general also line. Wire bought. Do not pull the line when the thread can be broken on the line. The The
- Q: I upload room map, socket design, weak line design, please help friends to design "strong power circuit map." My house is ready to install solid wood flooring, weak electric pipelines ready to be traced from the wall. How is the strong wire wearer? More
- Use the national patent product easy gold plugging point detector, quickly and accurately find the plug point, look in the Google library to see! Saving time is the biggest benefit
- Q: The new house has just finished the renovation did not stay, then the air can be broken water pipes, soak for two days only to find the water inside the plug from the inside into the tube inside, when the plug out of the water out there, such a situation There is no future security risks, whether the water inside the pipe to dry, how to do specific methods to solve more
- Yes, they are all weak. Cable TV signal line outer ring with a shield, to a certain resistance to the outside world. Ultra-five network cable body also has a certain anti-interference ability, but the crystal head is best made by 568B connection method to do. The power and weak wires should be laid separately. The best choice of good wire, this point please note.
- Q: Wire pipe inlet air switch trip how to do?
- Hello: ZB-KVV-8 * 1.5 refers to the flame retardant B sheath material PVC insulated PVC sheathed control cable, which consists of eight core core, the nominal cross-sectional area of each core is 1.5 Square millimeter. General laying in the room, cable trenches, pipes and other fixed occasions. Thank you for adopting.
- Q: What is the difference between pvc tube 315 and 3o5?
- KXV? Is not the ah KVV cable Introduction: PVC insulated PVC sheathed control cable for rated voltage 450 / 750V and below or 0.6 / 1kV and below control, signal, protection and measurement system wiring purposes.
- Q: How to check the home line in the wire with a connector
- Direct protection of the cable in the following ways: cable laying with fine soil or sand cover the cable 100-150mm, the upper brick or cement board cover, the upper and lower layers of the gap is staggered, and then fill the tamping (backfill no miscellaneous And lumps), the protection of the pipe is generally used in the cable crossing, into the ground and the location.
- Q: Ask about the electrical engineering with a thin metal wire tube called what is called jdg or what to the
- Reply 15 # cable spacing coefficient can be seen commonly used data to find, personally feel that in the civil building, the cable trench can determine the cable spacing, the bridge in the actual construction of cable spacing is unrealistic. By the way, especially in the basement, a lot of large cable cases, 100 high bridge is often not covered.
1. Manufacturer Overview
Location | Zhejiang, China |
Year Established | 2002 |
Annual Output Value | |
Main Markets | North America 0.36% Eastern Europe 8.08% Southeast Asia 2.18% Mid East 0.40% Eastern Asia 0.17% Western Europe 0.08% Central America 0.17% Northern Europe 0.64% South Asia 0.60% Domestic Market 87.32% |
Company Certifications | ISO9001:2008 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | |
Export Percentage | 21% - 30% |
No.of Employees in Trade Department | |
Language Spoken: | |
b) Factory Information | |
Factory Size: | 5,000-10,000 square meters |
No. of Production Lines | 1 |
Contract Manufacturing | OEM Service Offered |
Product Price Range |
Send your message to us
PVC Trunking
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 2000 Meters m
- Supply Capability:
- 50000 Meters per Month m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches