PLUM TYPE MALE FLEXIBLE CONDUIT CONNEXTOR-ZINC
- Loading Port:
- Ningbo
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 pc
- Supply Capability:
- 300000 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Competitive Advantage:
Straight hose connectors are designed to slip onto the conduit quickly and to grip the con-duit jacket, speeding up installation while ensuring a strong,liquid-tight seal that decreases the risk of pullouts. All com-ponents of these hose connectors can be easily disassembled and reused. Additionally, the included sealing washers provide liquid-tight seals when hose connectors are terminated in threadless openings. The heavy-duty locknuts included with every Topele liquid-tight hose connector ensure the continuity of the grounding. Connectors are zinc electroplated for excellent corrosion protection in damp locations.
+Quick Delivery: within 30 days for one 20ft container.
+Competitive Price
+ Good Quality: ISO/UL certificate approval
+Best Service: fast delivery, strong package, good price, timely and effective communication
+Powerful Solution: fast and effective solution to problem.
- Q: 1000 kW 600 m cable to use much
- Such a large load so far away, can only be transported with 10KY, near the installation of the transformer Caixing, if the 380V transmission, cross-sectional area, high cost, loss of large, not worthwhile. 10KV high-pressure delivery, current 55A, with 25mm? copper cable 35mm? aluminum cable delivery on it. If the 380V transmission, according to the line voltage loss simple calculation formula △ U% = PL / CS take △ U% = 5 copper cable S = PL / CS △ U% = 1000X600 / 77X5 = / 385 = 1558mm? aluminum cable S = PL / CS = U06 / 46X5 = / 230 = 2307mm? Line voltage loss △ U Simple calculation formula △ U% = PL / CS △ U% - Percentage of voltage loss P - Active power of conveying (Kw) Distance of L- M) C-constant, aluminum single-phase 8.. aluminum three-phase four-wire 46; copper single-phase 12.. copper three-phase four-wire 77S-conductor cross section (mm?) (quoted from "electrical entrance permit test low pressure Class theory "" electrical engineering basis ")
- Q: Is the cable head made of every building?
- First, the cable production and installation of each building has. Second, the cable terminal set of waterproof, stress control, shielding, insulation in one, with good electrical and mechanical properties, in a variety of harsh environmental conditions for long-term use. With the advantages of light weight, easy installation and so on. Cable terminal is widely used in electric power, petrochemical, metallurgy, railway ports and construction and other fields. Third, the production process: including the following: . cut off the excess cable; . the cable protective layer of the stripping; . conductor connection; . wrapped around insulation (or shrink pipe); . install the connector shell; . ; . for sealing treatment.
- Q: What is the meaning of PG + digital markings for electrical wiring?
- If no color distinction, 100 meters after you know which line of the fire line which line? The
- Q: How much of the cable with the switch?
- The switch is not selected according to the cable and is selected according to the current. The cable is determined by the size of the power (converted to current) and the distance from which the distance is far. The greater the power distance, the greater the cross-sectional area of the required cable. For example: 15KW motor selection cable current I = P / 1.732UcosΦ = 15 / 1.732 / 0.38 / 0.8 = 28A if it is close (within tens of meters), copper cable 6 square millimeters, aluminum cable 10 square millimeters. If it is in the distance (a few hundred meters), copper cable 10 square millimeters, aluminum cable 16 square millimeters. If it is long distance (close to kilometers), copper cable 16 square millimeters, aluminum cable 25 square millimeters. The switch is regardless of distance, completely based on the load current to choose, generally according to the load current of 1.5 times to 2 times to choose.
- Q: Does anyone know the "line buckle" classification (including shape / size / material / has been some commonly used size!) Line deduction is a hardware products! For daily necessities!
- If you want to ensure that the transmission medium does not cause the signal to cause attenuation and interference, fiber transmission or balanced cable transmission is the best solution. If you need fiber transmission, the cost is high because you need to buy digital fiber converters and digital audio decoders and related equipment, but this can be to the maximum extent to ensure the integrity of the signal and the smallest noise interference. If you want to use low-cost transmission can also be used directly to the cable transmission, but must use a balanced interface for transmission, and with 2-core shield or 3-core, 5-core shielded cable for transmission. This can also ensure the clarity of the signal to the maximum extent, but do not eat hungry thirsty 丨 Chicken check blood sausage is too long. No matter how good the cable will be attenuated, the size of the attenuation will directly affect the signal quality and signal integrity. So the transmission distance with the balance line can not be too far. More than two kinds of transmission methods than the existing single-line transmission is much better, if you are a fever-level players, I suggest you use fiber transmission. But if your power amplifier or your source signal to noise ratio is not high, I do not recommend you use fiber transmission, because even if the quality of fiber transmission no matter how good your source is not high, then it does not make sense The
- Q: 5 air conditioning can be used 4 square cable
- You do not use the 9V power supply, a long time will burn the router.You'd better measure the original adapter voltage, if you want to extend the power cord, it is best to use a thick line of reliable connection, you can not start now, you can not start Depending on whether the extension line is too thin, causing the voltage drop too much.It is necessary to extend the front end of the adapter can extend the 220V power cord.
- Q: The difference between nylon balls and geese and ducks
- If the 2.5 square copper wire for the output extension cable, 20 meters distance, the total resistance of about 2 * 1.7 * 0.2 / 2.5 = 0.272 (ohms), the current maximum 1.8A, the voltage drop is 0.272 * 1.8 = ), The charging voltage is 55-0.5 = 54.5 (volts), a difference of about 1% will not have any impact on the battery. However, the third floor, said Ye Hao, you can put the charger put the debris room, from your house put a 220V power cord down, home and then engage in a switch control. It is best to design a light at home, can intuitively see if the electricity is full. That's better. Design light, teach you a way: to find a bad leakless protector, open there is a coil-like ring-shaped stuff, called zero sequence current transformer, it will be down, be careful, do not put Transformers inside the coil hurt, get down, in the transformer two thin lines connected to a light-emitting diode. And then your 220V power cord line of fire from the center of the sensor through, around 3-5 turns. In this way, as long as there is current flow, the light-emitting diode will be bright, when the charge is over, the charging current is close to zero, the light-emitting diode will be extinguished. You can from the light-emitting diode is lit to determine whether the electric has been filled. I also have an electric bike that is so charged.
- Q: How do I ask for cable prices? How many tons is one or more?
- Yellow line is video, red and white are audio, you can only pick one!
- Q: 6 square cable up to how many air conditioning (1.5P)
- 7 kilowatts of electricity with what specifications of the wire if it is single-phase 220V, then 7 kilowatts of current is 7000 × 220V = 31.8A, check the electrical manual 4 square copper wire interception is 33A, to meet the requirements.
- Q: 25 square copper cable how much money one meter?
- There is no 1..2..4.5 square wire. The family uses most of the four wires with 1.. 1.. 2.5 and 4. Power 1KW Approx. 5A.3KW Approx. 15A.2.5 square copper wire can be used. Plug or empty open (25A).
Send your message to us
PLUM TYPE MALE FLEXIBLE CONDUIT CONNEXTOR-ZINC
- Loading Port:
- Ningbo
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 pc
- Supply Capability:
- 300000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches