Application

    This  product is suitable for using as all different kinds of rubber  insulated flexible mine used cable with A.C voltage of 6 kV and below.

Type and Designation


Designation

Standard

GB/T12972.110-1991

MT818.110-1999

Type

Coal excavator used rubber covered    flexible cable

UC-0.38/0.66

MC-0.38/0.66

Coal excavator shielded rubber covered  flexible cable

UCP-0.38/0.66

UCP-0.66/1.14

MCP-0.38/0.66

MCP-0.66/1.14

MCP-1.9/3.3

Coal excavator metal shielded rubber   covered  flexible cable

UCPT-0.66/1.14

MCPT-1.9/3.3

Coal excavator metal shielded supervising rubber covered  flexible cable

——

MCPTJ-1.9/3.3

MCPTJ-0.66/1.14

Coal excavator shielded supervising   braided enhanced rubber covered    flexible cable

UCPJB-0.66/1.14

MCPJB-0.66/1.14

Coal excavator shielded supervising   wrapping enhanced rubber covered    flexible cable

UCPJR-0.66/1.14

MCPJR-0.66/1.14

Mine electric driller used rubber   covered  cable

UZ-0.3/0.5

MZ-0.3/0.5

Mine shielding electric driller rubber   covered  cable

UZP-0.3/0.5

MZP-0.3/0.5

Mine moving rubber covered  flexible cabel

UY-0.38/0.66

MY-0.38/0.66

Mine moving shielding rubber covered    flexible cable

UYP-0.38/0.66

UYP-0.66/1.14

MYP-0.38/0.66

MYP-0.66/1.14

Mine moving metal shielding rubber   covered flexible cable

UYPT-3.6/6

MYPT-1.9/3.3

MYPT-3.6/6

Mine moving metal shielding supervising   rubber covered flexible cable

UYPJ-3.6/6

MYPTJ-3.6/6

Mine moving light duty rubber covered   flexible cable

UYQ-0.3/0.5

MYQ-0.3/0.5

Mine worker cap used cable

UM

UM-1

MM


Technical parameter

1At 20 D.C resistance of the category 5 tining flexible conductor should comply with requirement of GB/T3956.

2Electrical insulating performance

Insulating resistance constant Ki shall not exceed 180MΩ·km at 20℃;

Power frequency A.C voltage test:

Type of the insulation core

Rated voltage

kV

Testing voltage (virtual value)

kV

Time of operating voltage

min

Driving core

3.6/6

11.0

5

1.9/3.3

6.8

0.66/1.14

3.7

0.38/0.66

3.0

0.3/0.5

2.0

Control core

1.5

3、  Coal  excavator used rubber flexible cable and mine used moving flexible  cable with voltage of 1.9/3.3kV and below shall have the following  performance:

Times of mechanical resistant impact shall be

Nominal cross-section16mm235mm2···············2 times

Nominal cross-section50mm295mm2···············3 times

Pressure of press resitstant

U0/U0.38/0.66kV····························20kN

0.66/1.14kV····························30kN

1.9/3.3 kV····························40kN

4、  Coal  excavator used rubber flexible cable with voltage of 1.9/3.3 kV and  below shall have the bending resistant performance, it shall not cause  circuit breakdown and short circuit after 9000 times bend.

Feature

Coal  mine used cable has good impact, bending and press resistant  performance, especially the fire resistant and flame-retardant  characteristic. It also has operating secure and good earthing  performance.


Q: What is the difference between the power BV line and the power YJV cable?
According to the provisions of GB-. pipes with a diameter of 15 mm can wear 3 BV-2.5 or 2 BV-4; and so on, 20 mm pipe, 3 * 4 or 4 * 2.5; 25 mm pipe, * 6 mm or 5 * 4; 32 mm tubing, wear 3 * 10 or 5 * 6; 40 mm tubing, wear 4 * 16 or 5 * 10; 50 mm tubing, wear 4 * 25 or 5 * 16 The The combination of the above, generally can be applied to all the current distribution lines of the way. As for the 35 square millimeters above the wire, the general use of cable laying, do not use PVC pipe, you can see the environment as a result of the application or wear pipe protection.
Q: how can i calculate the current carrying capacity of a power cable when the area is given?can you give me a table on this?
Table 310.16 of the NEC (2008)
Q: This type of cable with the armor without expert advice, thank you. More
Eight or six no less, the first good fire retardant pipe on the line, the box can be opened after the slot
Q: Where to plug the power cable wich includes in HIS Radeon 3850? And it so short , cant imagine where it will go.. plz someone help me..
they Plug into a molex connetion on your PSU(power unit) its the samething that connects to your CD-rom and Hard drives but be forewarned the 3850 needs a 500watt PSU to run right or you will burn it out
Q: I have a Benq scanner 5000 and have lost its power cable.Please tell me what adapter to buy! input = 220v
The power cable and adapter will probably be unique to the scanner. You'll have to order the right one from HP, or through a computer store. The USB cable should be standard. Most printers and scanners use a USB cable with a Type A connector (flat) on one end, and a Type B connector (squared-off) on the other end. They're easy to find at Staples, as well as at computer stores.
Q: So i'm trying to start up an old windows 98 model. I was thinking of using the cable from a laptop because it fits into the power supply. Problem is i don't know if its safe, advice?. On the computer it says quot;AC input: 115V~/230V~,10/5A 60/50HZON the power cable on the other hand, it says 16A 250VAm i good to go?
Both the 250v and the 15A are higher than the computer will need / be consuming So it is safe to use.
Q: hai am working with QATAR PETROLEUM i have one job i have to supply barrier i have the barrier power supply for barrier 120/230v which braker and which cablecore with formula i have to submit for approval regardsravi
contained in the former days we used to partition off because of the speeds of not worry-free drives and how records replaced into saved. Now a days, distinct walls do not some thing for speed, the really authentic positives could be a million, once you've a Boot Partition, sufficiently enormous to take care of the OS, and under no circumstances set up any courses on it, then one partition on your courses, and a very last partition on your records. in case you ever favor to reinstall or format the OS, you received’t lose your records. in my opinion even with the indisputable fact that, I don’t partition some thing, I run 500GB for my important force, then use an exterior 1TB for backups. So, to respond to your question a touch extra obviously, searching on the way you've it partitioned, it can slow your computing device down, or do not some thing solid or undesirable. it received't income you in speed except from what i discussed above conserving the OS on a separate partition so it does not get affected by capacity of courses being put in and uninstalled. no count the way you examine out it, 7 drives is way too a lot.
Q: what kind of power supply cable plugs into the hard drive?
Which okorder /
Q: how deep underground are electric cables put and gas pipes laid underground for houses and bungalows here in the united kingdom,the Supply would be coming from the street up the front garden,asking this as thinking of knocking in metal posts for garden fence,
I apologize for the first answer. I can't imagine that basic building code is too different in the UK. The utility companies should have the information on file, and possibly your municipality. But the best bet is to see if they mark it for you. If that fails, I would pick up a manual post hole digger and some quick set cement and cement the posts in (i/m/o, this would be the way to go anyway as it gives you a much more secure post, plus you avoid having to wait on the utility company). Good luck.
Q: Hello,We are having a problem with our power cable and that being that most time whenever we insert the power cable into the back of the laptop the orange light at the front of the laptop does not always light up. We think the problem lays with the power cable, because it has been tugged and dropped before on many occasion.So, is it possible to buy a power cable for our Toshiba laptop, and we have retained the sticker. We think that the Toshiba part no is PA3396E-1ACA and the model no is PA-1650-02.So is it possible to buy a new power cable?
it sounds as if the jack plug on the board needs doing. it is a common problem and reasonable in cost to repair.

Send your message to us