Mica Tape consist of phlogopite mica paper (or synthetic mica paper) impregnated with special silicone resin and glass fiber cloth
(or Polyethylene film) as supporting agent. These tapes have great flexibility and high tensile strength, and their combined
characteristics mean they can be used to create inorganic, fire-resistant insulation for electrical cables.

TYPES
Our high quality mica tape classified 4 types as follow:
◆ST-MG: Single side reinforce phlogopite mica tape with glass fiber cloth ( Phlogopite Mica & Glass fiber cloth)
◆ST-MP: Phlogopite mica tape with PE film on single side (Phlogopite Mica & PE)
◆ST-CG: Single side reinforce calcincated muscovite with glass fiber cloth (Calcincated mica& Glass fiber cloth)
◆ST-SG: Single side synthetic mica tape with glass fiber cloth ( Synthethic mica & Glass fiber cloth)

AVAILABILITY
◆ Thickness:0.08mm-0.15mm
◆ Width:4.5mm-1000mm
◆ Length:300m 500m 1000m 2000m
◆ Standard cores:52mm 54mm 76mm 120mm

Q: Who know what kind of fire shutter fire rating are there?
There is no national standard for fire protection performance of fire roller shutter in China, and now the executive standard of GB14102-2005 "fire shutter": F1, fire-resistant time 1.50h; F2, fire-resistant time 2.00h; F3, fire-resistant time 3.00h; F4, fire-resistant time was 4.00h before the national standards of fire shutter grading is introduced, expert advice that fire resistance test be made according to national standard, to reach back fire surface temperature rise requirements, if the refractory limit is greater than or equal to 3.0h, it is said to be super fire shutter, if test not inspect unexposed surface temperature rise as a judgement of the conditions, the door is referred to as ordinary fire shutter doors. I hope my answer can help you
Q: What are included in wall fireproofing material?
Wall fireproofing materials include dry wall and gypsum block. Dry wall is made into board material through process by using building plaster as main material, adding an appropriate amount of additive and fiber to make board core and using tailor-made board paper as protection surface. Dry wall ia characterized by light weight, sound insulation, heat insulation, strong processing performance and easy construction method. Gupsum block is lightweight building plaster product made by using building plaster as main raw material, adding water, stirring, moulding by casting and drying. Fiber reinforced material or lightweight?aggregate are allowed to add during the production and foaming?agent can also be added. It is soundproof, fireproof, convenient to construct and many other advantages. It is a kind of new wall material with low carbon, environmental protection, health and in line with the development requirements of the times.
Q: how to use boiler fireclay
Boiler refractory, diluted with water to touch the places where needed, can be used after high temperature baking.
Q: How long is the fire resistant limit for ultra thin fire retardant coating?
The fire resistant limit of ultra-thin fire retardant coating is 1.5 hours, generally fire resisting time for thin fire retardant coatings does not exceed 1.5 hours. If the time exceeds 1.5 hours, thick fire resistive coating should be uesd. There is no detailed stipulation for ultra-thin fire retardant coating, and the thickness of the inside is the fire resistance limit shall reach certain time(at least). If fire resistance limit is 2.5 hours, the thickness shall be 4.9mm. If the fire resistance limit is 2 hours, the thickness is 3.5mm. If fire resistance limit is 1.5 hour, the thickness should be 1.75mm.
Q: Do you know the refractories?
Acidic material products: these products to quartz (SiO2) as the first phase, SiO2 is an acid oxide, helped named. Brick is representative of the product acid material; semisilica brick, alkali proof brick, acid brick in SiO2 content of 60% to 80%, is a semi acidic material.
Q: What are the differences between first-level fire-resistant materials and second-level fire-resistant materials?
1, these refer to fire resistance rating of building materials. 2, As for steel, elements that used in different parts should reach different duration of fire resistance according to fire resistance rating. For example, fire resistant pillars of first level can endure fire within 3 hours; the second level, 2.5 hours; the third level, 2 hours. With respect to beams, three levels of fire resistance are included.
Q: What is the main material of fireproof wooden door?
Fireproof wooden door has a lot of materials! including imported timber decorative effects: utilizing the diversity and easiness to cut of the timber, with all the decorative characteristics of the timber. Material selection features, door frames: Using high-quality hardwood, such as imported miscellaneous wood, camphorwood, lauan, hemlock, etc., insetting fire and smoke proof adhesive tape
Q: What are the commonly used fire protection materials
Firewall. The fire wall is made of non combustible material, and is directly installed on the base of the building or the reinforced concrete frame or fire proof walls . Fireproof limit of the firewall, according to the current "building regulations", is 4 hours, wheras the specification of Technical specification for concrete structures of tall building is 3 hours. doors resistant to fire, heat in a certain period of time These door usually prevent the spread of fire and gas in the fire resistant wall, staircase, pipe well. Fire door can be divided into steel fire doors, wood fire doors and composite materials fire door according to the material used. According to the limit of fire resistance can be divided into the class A fire door (1.2h), B fire doors (0.9), class C fire door (0.6h); (3) fire window. Windows resistant to fire, heat in a certain period of time It is usually installed in the fire resistance wall or doors; the fire shutter. This roller shutter can be refractory in a certain period of time. It is typically used for heat and fire insulation in escalator with difficulties to install fire resistant wall, fire resistant valve and smoke resistant valve. Fire resistant valve is installed in the ventilation and air conditioning system of air supply and return air duct, usually in the open state, fire, It will be turn off when the pipeline gas temperature reached 70 degrees, can meet the requirement for fire resistance and insulation for gas and fire. Smoke fire resistant damper installed in the exhaust system pipe, when the pipeline gas temperature reached 280 degrees, it will close automatically, insulating fire and gas.
Q: What are the materials of class A fire resistant window?
The filling materials of steel, wood frame should be non-combustible materials. Fireproof glass can use qualified products that do not affect the fire window fire resistance performance, whose light transmittance should be no less than 75% that of the commom sheet glass with the same layers. Sealing materials between the frame and fireproof glass should be nonflammable materials. Hardware fittings should be fixed supporting products that pass the test.
Q: How to divide fire resistant level of fire door?
Fire resistant level of fire door【Class A fire door】. Class A fire door is also called complete fire door. It can meet the requirement of fireproof thermal insulation and refractory integrity at the same time in specified time. Fire resistant levels are 0.5h(Grade C), 1.0h(Grade B), 1.5h(Grade A) and 2.0h, 3.0h. 【Class B fire door】Class B fire door is also called part heat insulation fireproof door. Its requirement of fireproof and thermal insulation performance is 0.5h. Refractory integrity levels are 1.0h, 1.5h, 2.0h and 3.0h respectively. 【Class C fire door】Class C fire door is also called not thermal insulation fireproof door. Ther is no requirement of its fire resistance and thermal insulation. It only meets the requirement of refractory integrity in specified refractory time. The grading of refractory integrity is 1.0h, 1.5h, 2.0h and 3.0h respectively. There is the content of not thermal insulation fire door in British BS standard.