• Lug Type Butterfly Valve Without Pin Ductile Iron DN80 System 1
Lug Type Butterfly Valve Without Pin Ductile Iron DN80

Lug Type Butterfly Valve Without Pin Ductile Iron DN80

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
50 set
Supply Capability:
20000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Centerline structure,pinless double half shaft design.
Disc has two-way bearing, no installation direction requirements.
Non-backed replaceable seat with good performance and a longer working life.
Square and short neck for lable use and cost saving.
Easy installation, no need flange gasket.

 

SizeDN50mm-DN600mm
Design standardAPI609/EN593
End flangeDINPN10/PN16, BS4504PN10/PN16, ANSI class125#/class150#
Face to faceAPI609/EN558-1
Top flangeISO5211
BodyDuctile iron/Cast iron
DiscDuctile iron/CF8/CF8M/C95400/C95500
StemSS420
SeatEPDM/NBR/Viton/PTFE
ActuatorBare shaft/Lever/Gearbox and handwheel
CoatingEpoxy/Nylon/PTFE
PinWith out pin
Suitable mediumWater/Seawater/Sewage/Air/Foodstuff/Oil

 

Q: 16 inches below the choice of electromagnetic valve can be the same, it turned out to be DN200 election 1/4, and now there are DN350 can also use this? With it, limiter, pressure relief valve, locator model will change?
The valve (including the valve, butterfly valve, etc.) are equipped with pneumatic actuators are standard (including restrictor valve positioner of the electromagnetic valve is connected with the installation.) is the international standard NAMUR standards, in the standard of inside electromagnetic valve is G1/4, of course, this is the solenoid valve installation in the NAMUR interface of the driver on the situation, if the solenoid valve is not installed on the drive, but through the trachea installed in a few meters away, it would have to choose a larger size, how to choose? Depends on the switching speed of the valve requirements, such as drive gas consumption is 2L, need to open in 1S, the electromagnetic the valve requires the flow of 120L/min, plus the line loss and acceleration, 500L/min is enough.
Q: Electric butterfly valve (not take the lead) what do you mean?
Electric butterfly valve, as its name implies, consists of an electric actuator and butterfly valve, and the customer does not take the lead, that is, without the electric actuator, only the butterfly valve can be provided.
Q: My caravan is a bit sluggish on the pick up, I replaced the wires/plugs and the electronic distributor(I think thats what it is..). still a bit sluggish. Should i look at the valve gasket? Or fuel filter, or fuel pump next? 03 caravan sport 3.3L
the valve pan gasket won,t cause it but the fuel filter will if it,s starting to clog up and also the cat nverter !
Q: What does "10" in the butterfly valve "D71X-10" mean?
The pressure of 10 kg 1.0MPA is usually cast iron
Q: What's the difference between a butterfly valve and an eccentric butterfly valve? What is the difference in field applications?
Eccentric butterfly valve and ordinary butterfly valve, when the butterfly valve is opened, the eccentric butterfly valve sealing surface will reduce great wear, in the opening, the disc will leave the valve at the first time the sealing surface!
Q: The water supply pipe is the gate valve And on the cross dry pipe are the gate valve? To answer the 30
Crown valve pressThere is no standard answer to this question. I can only give you my personal opinionRiser butterfly valve is generally place in these places (the pump outlet valve, drainage system, upper and lower floors) riser are basically installed butterfly valve, butterfly valve is not cheap, fast speed is fast closing butterfly valve can be quickly closed and open educationYou see the water pipe installed valve (with all the cross tube is the basic gate) explanation, because in contrast to the quality and stability, the valve will be better, the site does not need fast switching, it will choose good stability point gateSum upThe drains are all butterfly valves, and the stabilizing pipes are all valves! (do not rule out a full use butterfly valve for stealing work)
Q: Is the pressure test of the centerline butterfly valve checked or checked?
The pressure test of the central butterfly valve is carried out at each station.Basis:1) GB/T12238-2008 flange and clamp connection elastic seal butterfly valveRules: butterfly valve must be carried out by factory inspection and testing, inspection qualified before leaving the factory.2) CJ/T 261-2007, butterfly valves for water supply and drainageRules: each product shall be inspected by factory and quality inspection department. After inspection, the product certificate shall be attached to the factory.Butterfly: also known as butterfly valve, control valve has a simple structure, can be used for low pressure pipeline valve switching control is closed parts (disc or disc) is a disk, around the valve axis to achieve the opening and closing a valve, the valve can be used to control air, water, steam, all kinds of corrosive media, mud, oil, metals and radioactive liquid media and other types of fluid flow. On the pipeline, mainly from cutting and throttling. Butterfly valve headstock is a disc shaped disc, in the valve body around its own axis of rotation, so as to achieve the purpose of opening or closing or regulation.
Q: For example, the arrow above is from left to right, and the direction of my current is from right to left. Is that ok? I have a diameter of 700 of the hard seal butterfly valve is so installed, but it will leak water, it will not leak, very serious
From the above example, it can be concluded that the arrow direction of the butterfly valve body refers to the direction of the pressure of the medium. Before the installation, the user must know the direction of the pressure of the valve after the valve is closed. The direction of the arrow of the free valve body is in accordance with the direction of the pressure of the medium, so that the correct use can be achieved, and the tightness of the valve body is kept in good condition.
Q: Fire signal butterfly valve what role?
Signal butterfly valve should be human action monitoring alarm, once closed, that is, to the system alarmYou ask the two time, I answer two times, you give two points
Q: What is the national standard for clip butterfly valves?
GB/T 12238-2008 "flange and clip connection elastic seal butterfly valve"GB/T 26144-2010 flanged and clip on steel lined fluoroplastic butterfly valvesJB/T 8527-1997 "metal sealed butterfly valve"