• HV copper conductor  armoured underground power cable System 1
  • HV copper conductor  armoured underground power cable System 2
  • HV copper conductor  armoured underground power cable System 3
  • HV copper conductor  armoured underground power cable System 4
HV copper conductor  armoured underground power cable

HV copper conductor armoured underground power cable

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
500 m
Supply Capability:
1000000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

HV copper conductor  armoured underground power cable

1.Factory price
2.international standards
3.fast delievery                 

Executive standard

International: IEC 60502-2, IEC 60228, IEC 60840, IEC62067

Chinese: GB/T 12706.1~12706.3-2008

Other standards such as BS,DIN and ICEA upon request

 

Applications

For laying indoors , in tunnel, cable trench, well or direct in ground, able to bear external mechanical forces and certain pulling force .

The product is suitable for use in power transmission and distribution lines with ra

power frequency voltage 3.6/6kv~26/35kv.

Operation characteristics

  1. Rated power-frepuency voltage U0/U: 3.6/6kv~26/35kv

  2. Max. admissible operating temperature of the conductor:90

  3. Max. short-circurt temperature of conductor shall not exceed 250.
    (5s maximum duration)

  4. The ambient temperature under installation should not below 0

  5. The bending radius of a single-core cable should not less than 20 times of the cable diameter.
    The bending radius of a three-core cable should not less than 15 times of the cable diameter.

Type of cable

Type

Designation

Application

YJV

Copper conductor, XLPE insulated and PVC sheathed power cable

For laying indoors , in tunnel or cable trench, unable to bear external mechanical forces. Single-core cable in magnetic duct is not permissible

YJLY

Aluminum conductor, XLPE insulated and PVC sheathed power cable

YJY

Copper conductor ,XLPE insulated and PE sheathed power cable

YJLY

Aluminum conductor ,XLPE insulated and PE sheathed power cable

YJV22

Copper conductor ,XLPE insulated, steel tape armoured and PVC sheathed power cable

For laying indoors , in tunnel, cable trench, or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force

YJLV22

Aluminum conductor ,XLPE insulated ,steel tape armoured and PVC sheathed power cable

YJV23

Copper conductor ,XLPE insulated ,steel tape armoured and PE sheathed power cable

YJLV23

Aluminum conductor ,XLPE insulated ,steel tape armoured and PE sheathed power cable

YJV32

Copper conductor, XLPE insulated, steel wire armoured and PVC sheathed power cable

For laying indoors , in tunnel, cable trench, well or direct in ground, able to bear external mechanical forces and certain pulling force .

YJLV32

Aluminum conductor ,XLPE insulated, steel wire armoured and PVC sheathed power cable

YJV33

Copper conductor ,XLPE insulated ,steel wire armoured and PE sheathed power cable

YJLV33

Aluminum conductor ,XLPE insulated ,steel wire armoured and PE sheathed power cable

Production range of cable

Type

Nomber of cores

Rated Voltage kV

3.6/6

6/6 6/10

8.7/10 8.7/15

12/20

18/20 18/30

21/35

26/35

Nominal cross-section of conductlr mm2

YJV
YJLV
YJY
YJLY

1

25-800

25-800

25-800

35-800

50-630

50-630

50-630

3

25-630

25-630

25-500

35-500

50-400

50-400

50-400

YJV22
YJLV22
YJY23
YJLY23

1

25-800

25-800

25-800

35-800

50-630

50-630

50-630

3

25-630

25-630

25-500

35-500

50-400

50-400

50-400

3

25-630

25-630

25-400

35-400

50-240

50-185

50-150

 

Workshop

 

Package & Shipping

 

 

 

Q:On my PSU I have two PCI-E 6 pin cables. I have looked at the motherboard and saw there is nowhere to plug it in and my motherboard manual says of no slots for it but I do have two PCI-Express slots. Do they plug into the cards themselves or something?How do I use the PCI-E power cables?
The PCI-E power cables plug into cards that require more power than the PCI-E slot can provide. Usually this is only needed for higher-end video cards.
Q:What is the heat of the cross-linked cable?
Video cable refers to the transmission of video signals (VIDEO) cable, can be used as a monitoring system for signal transmission
Q:I have one Ethernet cable running to a WiFi antenna. The antenna is powered by the Ethernet cable, using PoE. I want to be able to plug the current cable into a hub or switch, so I can connect other devices (non PoE) like an Xbox 360 or PC, but I also need to maintain the PoE to the antenna. Taking the antenna off PoE is not an option. What kind of device can I use to split this PoE line into PoE and non PoE cables?
familiar ethernet cable is nice for 100m (approximately 328 ft), Any device which includes a hub, router etc. oftentimes acts as a repeater, 'cleansing' and boosting the sign to make greater desirable the variety. The distances you point out will have not any impact on ethernet. besides the shown fact that any undesirable connection or cable alongside the way can doubtlessly injury the sign. I have not any issues extending broadband ethernet hyperlinks over a number of thousands of metres with strategically placed small switches alongside the way for serious enterprise use.
Q:having trouble finding a spot to run a power cable throught the fired wall of a 97 oldsmobile cutlass supreme
Normally, when I do systems, I run it through the hole in the firewall, that was factory drilled for the antenna wire. Unfortunately, I dont think the antenna in this car is located up front, so. People run wires through the door. I personally don't like this, because you can see.. My personal opinion, would be to drill a hole on the passenger side, underneath the dash,and fill the gaps with silicone and run your wires down the side of the door, pushed under the plastic.
Q:Suppose load is 100KW, length 50m, how to calculate cable size. If we know current Is any easy mathod to calculate cable size.
There are two issues to consider, cable heating and voltage drop. Of the two, voltage drop is by far the easiest. You need to determine what the allowable voltage drop in you cable is. The voltage drop is just I x R where I is the current and R is teh round trip cable resistance. The specification of 100 kW isn't enough. If its a high tension 100 kV line, the current is only 1 amp and a run of 16 AWG wire would deliver about 99,999 volts out of the original 100,000 volts to your load. If its a 100 volt system then a 4 AWG wire would only deliver only 20 volts to the load. The formula for wire resistance (in AWG) is that 10 AWG has 0.001 ohm/ft. Each increase of 1 in the gauge increases resistance by the cube root of 2 (about 25%). You calculate by picking what voltage drop you can live with, for the known current figure the resistance, knowing the length figure the resistance per foot, and then pick the AWG using the above. The second concern is wire heating. Although you could do the heat transfer calculations, instead look up the allowable ampacity for any wire in an electrical engineers or NEC handbook.
Q:I have an Apple powerbook g4, and my original power adaptor broke. So I bought a new one online, not an original mac one as they are too expensive for me! But this new one makes my tv, stereo and even the sound from headphones plugged into the laptop buzz or go funny. I don't really have a major problem, I can handle the buzzing, but is this a health problem? Like weird electro-magnetic cancer causing stuff?
your future u must reach a problem that your battery will be damage or dead cos the adapter have the circuit and done currect power plan of laptop so dont use the un authorised hardwares that cause ur system damage or dead and the vendors donot have any responsibilities for ur computer
Q:I have a MSI K7 Motherboard... it has a SATA power cable but no data cable. Which kind of confuses me. Please help. Thanks =)
the prvios responses are precise, yet there is two extra issues to evaluate. a million. till you're development your very own new pc, establishing the case advert putting this 2nd stressfulpersistent in will void the guaranty on any new pc this is keep offered or oredered from dell, etc. 2. The stressfulpersistent has jumpers on it that tell the stressfulpersistent what function it has. Ie cable choose, grasp, slave, secondary slave. maximum drives are set to cable choose from the production facility, so be beneficial to plug it into the 2d plug on your unique ide ribbon cable. each from time to time you certainly would desire to alter the jumper to slave in case you purely have an ide cable with a single connector. i'd in my opinion shop the old pc working, connect it to a router/swap and share the cpersistent out. Then i'd get right of entry to the old one from my new pc and replica purely the documents i'd desire to my new one. Your documents are oftentimes placed ordinarily if no longer completely interior of your profile folder. this variety you're purely copying image documents, song, faves, etc.. Makes it much less stressful to ward off copying over a virulent disease or any corruption. reliable luck and congrats!
Q:What is resistance of the cable (resistivity of copper is1.7x10^-8)Answer is 14 ohms. But please explain how do we get there in full detail.
Resistance (R) of a wire is given by: R = ρ.L / A where (ρ) is the resistivity of the wire in Ω.m ; (A) is the cross sectional area of the cable in m? ; (L) is the length of the wire in metres. Radius (r) of one strand = (0.51 / 2) = 0.255 mm = 0.000255 m Cross sectional area of one strand = πr? = (π * 0.000255?) = 2.0428 x 10^-7 m? Total cross section of cable = (12 * 2.0428 x 10^-7 m?) = 2.45 x 10^-6 m? R = (1.7 x 10^-8 * 2000 / 2.45 x 10^-6) = 13.87 = 14 Ω to 2 significant figures.
Q:My mother has moved to Australia, taking her Fujitsu Siemens (Amilo model) laptop with her. Very shortly after, her power cable stopped functioning, and she would like a new one. Unfortunately, she is not tech-savvy at all and doesn't seem to be able to find the thing online, and I being from Europe, have trouble searching in her stead. I don't even know what an Australian plug looks like and I have no clue regarding the currency...All and any help is much appreciated.
This okorder Although that's some store from U.S, maybe you can try search it from OKorder or OKorder. Wish the Best
Q:NH-YJV-4 * 4 in NH-YJV-4 * 4 in power cable tube
6 points 1 inch equals 10 points 1 inch equals 3.3 cm 1 minute equals 0.33 mm

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords