Technical specifications

Table 2.3: Technical Parameters of QD200 Series Frequency Inverters

ITEM

SPECIFICATIONS

Main

Input

Rated voltage and frequency

Single-phase 200V class:  200V-240V,50Hz/60Hz

3-phase 400V class:  380V-480V , 50Hz/60Hz

Allowable value of change

Voltage: 380V-15% ~ 480V+10%;  Frequency: ±15%

Main output

Output voltage

Maximum output voltage equals to input voltage

Output frequency

0.5 Hz to 400 Hz

Overload capacity

150% of rated output current for 60s, 200% of rated output current for 2s

Control performance

Modulation mode

3-phase PWM, 2-phase PWM

Control mode

V/f control for constant torque, V/f control for quadratic load, vector control without PG (open loop control),Energy-saving

Setting method of run command

Outer terminal, keyboard panel or serial communication

Setting method of speed command

Analog setting, keyboard, serial communication, UP/DOWN speed setting from external terminal

Speed setting resolution

Keyboard: 0.1 Hz

Analog setting: 0.05/50Hz (10bit)

Speed control precision

V/f control:±2%

vector control without PG (open loop control): ±0.2%

Speed control range

V/f control 1:40

vector control without PG (open loop control)  1:200

Acceleration and Deceleration

Time

0-3200.0s

switching frequency

1.5 kHz ~ 12 kHz, according to junction temperature automatically reduce the switching frequency

Analog input

Number

2 ways: AI1、AI2

Type

DC voltage or DC current

Maximum input range

AI1: 0 to 5VDC, 0 to 10VDC, 0/4 to 20mA DC receivable

AI2: 0 to 10VDC or PTC probe input receivable

Analog output

Number

1 way: AO1

Type

DC voltage or DC current

Maximum input range

Voltage output: 0 to 10V, Current output: 0/4 to 20mA

logic input

Number

0.75kw-11kW:LI1,LI2,LI3,LI4,AI1,AI2

15kW-500kW:LI,LI2,LI3,LI4,LI5,LI6,LI7,LI8,AI1,AI2

note:2 virtual logic input, capable of configuring AI1 and AI2 into logic input port (positive logic or negative logic)

Type

Source or Sink

Maximum input range

0-24VDC

ITEM

SPECIFICATIONS

logic output

Number

0.75kW-11kW: pulse signal output (LO-CLO)、relay output 1(T1A、T1B、T1C

15kW-500kW:pulse signal output(LO-CLO)、relay output 1、2(T1A-T1B-T1C、T2A-T2B-T2C

pulse signal output

OC,output frequencycurrentoutput、ect other function

relay output

RA-RB-RC, including a NO contact and a NC contact

Maximum switch capacity:

T1A,T1B: 3A at 250VAC, or 4A at 30VDC

T2A,T2B: 2A at 250VAC or 30VDC

Serial communication interface

RS485 interface supports Modbus protocol.

Display

4-digit LED digital display

For display of frequency setting, output frequency, fault code and parameter setting etc.

Environment

Standard

Development of VSC200 series frequency inverters follows strict international standards and relevant recommended IEC and EN standards for control devices, especially IEC/EN61800-5-1 and IEC/EN61800-3.

Altitude

Derating unnecessary when altitude is 1000m or below (Derating necessary at altitude higher than 1000m)

Ambient environment

0.75kW-11kW: Reliable operation at -10 ~ 50°C without derating. When top protective cover is taken off, the environment temperature can be as high as +50 °C. Above +50 °C, the current drops by 2.2% for each rise of 1 °C in temperature. 15kW-500kW: Reliable operation at -10 ~ 40°C without derating.

Storage: -25 ~ 70°C

Humidity

No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3

Impact strength

15gn for continuous 11ms, In accordance with IEC/EN60068-2-27

Maximum antipollution capacity

Class 2, in accordance with IEC/EN61800-5-1

Structure

Protection level

Top: IP41 (without removing the protective top cover). Other parts: IP20

Cooling Method

Forced Air cooling

Installation method

Wall mounted

Q: The laptop power adapter is hot
My point of view: First: your laptop power supply in a small ventilation environment, resulting in poor heat dissipation, Second: the life of the power supply is 3-5 years, the gradual oxidation of electronic components and some of the aging components, resulting in no load and load a lot of power, Third: the battery close to each run, and then connected to the power, the power to the battery charger and notebook power supply, so the pressure is not hot strange.
Q: Motor nameplate on the standard 2P, I set the number of motor pole in the inverter, is set 2 or 4 pole?
1,2P refers to the number of motor poles, so it is certainly even 2, if the inverter is set to determine the number of motor poles, please write 2P value, if 2P = 4, please write 4 3, look at the nameplate on the motor rated speed for how much, you can confirm the number of motor poles. (N = 60f / p) P: pole pairs
Q: Acer laptop power adapter
It might be bad, you have to determine whether the adapter or adapter adapter directly change.
Q: Laptop adapter heat
Many friends to buy a laptop or laptop power, you may encounter the power did not take long to heat on the hot, and even hot to dare not get the situation, in the end is the quality of power problems or how is it? With the ever-changing notebook frequency, notebook power adapter power is also sesame flowering high, even to 100W or so, almost a small desktop power! Touch the hand, timid may be scared, obediently, is simply a hot potato! What will not fire? This is a lot of people worry! Compaq, IBM, such a large company to recover several back to the power adapter, it is because of fear that there may be defects due to power supply design, and will cause a fire!
Q: What is the characteristic of the variable pole speed method?
Three-phase asynchronous motor speed formula: n = 60f / p (1-s) From the above equation can be seen, change the power supply frequency f, the motor pole p and slip rate s can achieve the purpose of changing the speed. From the nature of the speed point of view, different speed control mode is nothing more than to change the AC motor synchronous speed or do not change the synchronous turn two. In the production machinery is widely used does not change the synchronous speed of the speed control method There are winding motor rotor resistance, chopping speed, cascade speed and the application of electromagnetic slip clutch, hydraulic coupling, oil film clutch, etc. Speed ??control. Change the synchronous speed of the stator to change the number of pole pairs of multi-speed motor, change the stator voltage, the frequency of the frequency control can not change the motor speed and so on. From the energy point of view of the speed control point of view, there are two methods of efficient speed control and inefficient speed control: high speed control when the slip rate is constant, so no slip loss, such as multi-speed motor, frequency control As well as the speed loss can be recovered speed control methods (such as cascade speed, etc.). There are slip loss of the speed control method is a low efficiency, such as the rotor string resistance control method, the energy loss in the rotor circuit; electromagnetic clutch speed control method, the energy loss in the clutch coil; hydraulic coupling speed , Energy loss in the oil of the hydraulic coupling. In general, the slip loss increases with the speed range, if the speed range is not large, the energy loss is very small.
Q: Laptop power supply 20V 3.5A can use 20V 4.5A power adapter Mody, what impact?
It's ok. As long as the voltage is appropriate on the line. Current value refers to the maximum current that can be output. How much depends on your computer. Or, with a big no harm, can only be better, if you can use a small, but a little longer charging time.
Q: How to choose the inverter
and you need to know how The use of frequency converter, as well as voltage 380, are fixed, and the frequency can be changed
Q: Old printing machine transformation, 37KW6 polar frequency motor with brake, inverter 55KW, now found running,
The frequency is too low or the brake gap is small
Q: Who knows how the inverter is calculated?
The synchronous speed of the two-pole motor is 3000 rpm,
Q: What is the output voltage of the laptop power adapter?
16V to 20V, different brands may be different, 19V, 20V more.