Frequency Inverter Single-phase 200V class 15KW
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Technical specifications
Table 2.3: Technical Parameters of QD200 Series Frequency Inverters
ITEM | SPECIFICATIONS | |
Main Input | Rated voltage and frequency | Single-phase 200V class: 200V-240V,50Hz/60Hz |
3-phase 400V class: 380V-480V , 50Hz/60Hz | ||
Allowable value of change | Voltage: 380V-15% ~ 480V+10%; Frequency: ±15% | |
Main output | Output voltage | Maximum output voltage equals to input voltage |
Output frequency | 0.5 Hz to 400 Hz | |
Overload capacity | 150% of rated output current for 60s, 200% of rated output current for 2s | |
Control performance | Modulation mode | 3-phase PWM, 2-phase PWM |
Control mode | V/f control for constant torque, V/f control for quadratic load, vector control without PG (open loop control),Energy-saving | |
Setting method of run command | Outer terminal, keyboard panel or serial communication | |
Setting method of speed command | Analog setting, keyboard, serial communication, UP/DOWN speed setting from external terminal | |
Speed setting resolution | Keyboard: 0.1 Hz | |
Analog setting: 0.05/50Hz (10bit) | ||
Speed control precision | V/f control:±2% | |
vector control without PG (open loop control): ±0.2% | ||
Speed control range | V/f control 1:40 | |
vector control without PG (open loop control) 1:200 | ||
Acceleration and Deceleration Time | 0-3200.0s | |
switching frequency | 1.5 kHz ~ 12 kHz, according to junction temperature automatically reduce the switching frequency | |
Analog input | Number | 2 ways: AI1、AI2 |
Type | DC voltage or DC current | |
Maximum input range | AI1: 0 to 5VDC, 0 to 10VDC, 0/4 to 20mA DC receivable AI2: 0 to 10VDC or PTC probe input receivable | |
Analog output | Number | 1 way: AO1 |
Type | DC voltage or DC current | |
Maximum input range | Voltage output: 0 to 10V, Current output: 0/4 to 20mA | |
logic input | Number | 0.75kw-11kW:LI1,LI2,LI3,LI4,AI1,AI2 15kW-500kW:LI,LI2,LI3,LI4,LI5,LI6,LI7,LI8,AI1,AI2 note:2 virtual logic input, capable of configuring AI1 and AI2 into logic input port (positive logic or negative logic) |
Type | Source or Sink | |
Maximum input range | 0-24VDC |
ITEM | SPECIFICATIONS | |
logic output | Number | 0.75kW-11kW: pulse signal output (LO-CLO)、relay output 1(T1A、T1B、T1C) 15kW-500kW:pulse signal output(LO-CLO)、relay output 1、2(T1A-T1B-T1C、T2A-T2B-T2C) |
pulse signal output | ||
relay output | RA-RB-RC, including a NO contact and a NC contact Maximum switch capacity: T1A,T1B: 3A at 250VAC, or 4A at 30VDC T2A,T2B: 2A at 250VAC or 30VDC | |
Serial communication interface | RS485 interface supports Modbus protocol. | |
Display | 4-digit LED digital display | For display of frequency setting, output frequency, fault code and parameter setting etc. |
Environment | Standard | Development of VSC200 series frequency inverters follows strict international standards and relevant recommended IEC and EN standards for control devices, especially IEC/EN61800-5-1 and IEC/EN61800-3. |
Altitude | Derating unnecessary when altitude is 1000m or below (Derating necessary at altitude higher than 1000m) | |
Ambient environment | 0.75kW-11kW: Reliable operation at -10 ~ 50°C without derating. When top protective cover is taken off, the environment temperature can be as high as +50 °C. Above +50 °C, the current drops by 2.2% for each rise of 1 °C in temperature. 15kW-500kW: Reliable operation at -10 ~ 40°C without derating. Storage: -25 ~ 70°C | |
Humidity | No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3 | |
Impact strength | 15gn for continuous 11ms, In accordance with IEC/EN60068-2-27 | |
Maximum antipollution capacity | Class 2, in accordance with IEC/EN61800-5-1 | |
Structure | Protection level | Top: IP41 (without removing the protective top cover). Other parts: IP20 |
Cooling Method | Forced Air cooling | |
Installation method | Wall mounted |
- Q: Laptop adapter
- The interface of the second adapter is the same as the first one And although the two numbers are not the same but the number of V on the line is the same as the interface
- Q: In the official website to buy ThinkPad notebook, to the power adapter?
- Tak City gifted, genuine low, 7 days unconditional return. 300 brand-name notebooks for you to choose.
- Q: How is the notebook with a power adapter?
- The safest option is to choose the same type of notebook power adapter. When in some cases (the original adapter is too expensive or not available), you can select the operating parameters and output connectors and the original adapter.
- Q: 5.5 kW 4-pole motor with the fastest speed can exceed the rated speed?
- Can not be exceeded Although the inverter can run out of the motor rated speed as the motor will soon burn You want your running speed of 2m / s you have to run 5m / s so go eggs do not pull the
- Q: Servo control system can give the inverter signal,
- but want two motor synchronization, it should be impossible, the converter does not reflect so fast, and the speed is not so stable.
- Q: Huichuan frequency converter drag a 4-kilowatt four-pole motor to change the six pole can?
- can. Re-enter the new motor parameters in the drive.Inverter motor power to 4KW, speed 980 can!
- Q: Can the laptop 1.3a power adapter be used on a 1.5a device?
- Theoretically impossible, because the power is small, but if it is a short period of time is possible, a long time to die.
- Q: What is the difference between AC and DC frequency converters?
- Inverter air conditioner is relatively speaking in terms of ordinary air conditioning, ordinary air conditioning compression motor using AC induction motor, speed unchanged, 50HZ when the speed is about 2880r / min. The inverter air conditioner is the first 220V, 50HZ single-phase AC into three-phase inverter AC (25 ~ 118HZ, 56 ~ 160), the supply of compressors, through the frequency changes to adjust the compressor speed, so that continuous cooling capacity to adapt to air conditioning Load needs. L inverter air conditioner works: inverter air conditioner compressor by the variable frequency motor drag, the power inverter output frequency changes in the alternating current to the motor, so that the motor speed can be based on the needs of indoor cooling and continuous change, the final compressor cooling capacity To achieve continuous changes in the automatic control. In order to meet the continuous changes in the cooling capacity, the refrigeration system uses an electronic expansion valve, the pulse motor switch valve core, rapid control into the evaporator refrigerant flow. Power frequency changes from the inverter to achieve, as shown in Figure 1: 220V, 50HZ of the mains input, the frequency converter A / D AC / DC conversion, D / A inverter, the output frequency required by the three-phase alternating current, Room switching power supply principle is similar.
- Q: The inverter flat rate transferred to 29, on the submersible pump to burn the coil ?!
- 4, high-speed motor: high-speed motor running process will produce a large number of harmonics, enhance the output current of the inverter, resulting in a lot of heat. Therefore, the inverter selection is also larger than the ordinary one gear. 5, explosion-proof motor: In some mines, oil extraction environment, the frequency conversion system is explosion-proof motor, the choice of inverter should use the explosion-proof function of the inverter, and the inverter placed in a safer place. 6, the degree of protection: for dust, wet applications, inverter selection should pay attention to its protection level. Or choose Ampang letter AMB inverter, the fan can also run in the water. 7, single-phase motor: When the scene using single-phase motor, the inverter useless. 8, variable pole motor: When the field using variable pole motor, the inverter selection should ensure that the maximum operating current should not exceed the rated current of the inverter
- Q: Jd1a-40 motor speed controller and how to connect the motor
- Third, cascade speed control method Cascade speed regulation refers to the winding motor in the rotor circuit in the adjustable additional potential to change the motor slip, to achieve the goal of speed. Most of the slip power is absorbed by the additional potential in series, and then an additional installation occurs, and the absorbed slip power is returned to the grid or converted to the energy. According to the slip power absorption application method, the cascade speed regulation can be divided into the motor cascade speed regulation, the mechanical cascade speed regulation and the thyristor cascade speed regulation situation, take the thyristor cascade speed regulation, Suitable for fans, pumps and rolling mills, mine hoists, extruders on the use. Fourth, winding motor rotor series resistance speed control method Fifth, the electromagnetic speed control motor speed method Six, hydraulic coupler speed control method This method is suitable for fan, pump speed.