MV VFD AC Motor Drive 3KV 6KV 10KV
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1PC pc
- Supply Capability:
- 10,000pcs/year pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications of MV VFD AC Motor Drive 3KV 6KV 10KV
Direct medium voltage input and output
IGBT power units in series to obtain MV by means of overlap wave
Up to 40% saving rate
Application Fields of MV VFD AC Motor Drive 3KV 6KV 10KV
Power Generation: Induced draft fan, forced draft fan, condensate pump, feed pump, primary air fan, secondary air fan, booster fan, circulating pump, mill fan, slurry pump etc
Cement: draft fan, high-temperature fan, air blower, dust collection fan etc.
Metallurgy: blast furnace blower, slurry pump, feed water pump, dust fan, compressor etc.
Petroleum&Chemical: Water injection pump, crude oil pump, Compressor, fan, circulation pump, etc
Urban water supply: Water delivery pump, water intake pump, water supply pump, sewage treatment industry, self-fractionating pump etc
Minerals & Mining: Mud pump, ventilation fan, slurry pump etc
Others: Loads such as fan, pump and compressor in pharmaceutical, paper making and wind tunnel test.
Especially for: Fan and Pump
Power Plant | Pump, Fans |
Steel Plant | Fans |
Cement Plant | Fans |
Product Structure of MV VFD AC Motor Drive 3KV 6KV 10KV
AC Motor Drive Variable Frequency Drive consists of By-pass cabinet, Transformer cabinet, power unit cabinet and controller cabinet from left to right.
Technical advantages of MV VFD AC Motor Drive 3KV 6KV 10KV
No need of extra output filtering device
Directly driving the general medium voltage synchronous or asynchronous motor and the temperature of the motor will not be increased.
No need of motor derating operation
No dv/dt damage to insulation of motor and cable
No torque ripple induced by harmonics, and the service life of motors and mechanism devices can be extended
No cable length limited when voltage drop is in the allowable range.
Besides the above advantages, AC Motor Drive MV Variable Frequency Drive has the following functions and features:
Protection of overload, overheat, over-current, open-phase, grounding, over-voltage, negative sequence.
Current limited function
Interlock protection of control power supply
Two sets of control power hot standby for redundancy
Power cell by-pass function
Control cabinet automatic bypass function
Cabinet door opening alarm function
Lock-phase function
Synchronizing switch function between variable frequency and power frequency (optional)
Soft start of motors, no impact to mechanical equipment and network
Voltage source High-high variable frequency drive, it can realize No-step speed regulation, which makes the typical motors into intelligent motors.
High quality power input: By phase shifting of the secondary winding and multi-pulse diode rectifier, isolated powers can be acquired and supplied for power cells. (18 pulses for 3/3.3kV, 30/36 pulses for 6/6.6kV, 48/54 pulses for 10/11kV) By using the technique of multi-pulse rectifier, the harmonic current could be eliminated greatly.
Power cell communicate with controller through optic-fiber, completely electric isolated
Inner set PID regulator, can realize running in closed-loop
Multiple communication methods with host computer, isolated RS485 interface, standard MODBUS RTU, communication protocol, PROFIBUS DP (optional), industrial Ethernet communication protocol (optional)
Accurately fault records, can inquiry information and locate fault
Compact construction, reasonable layout (can do customer-design)
Very good protective design to dust, ferrum pulveratum, acid mist, moisture etc.
Bypass cabinethas a function of "five-protection", meanwhile, it has a pressure relief channel to ensure the safety of operators.
Modularized design of power units, interchangeable and easy to produce and repair.
Technical parameters of MV VFD AC Motor Drive
Series No | Parameters | Value |
1 | HVF Capacity(KVA) | 250~8750kVA |
2 | Power of adaptive motor(KW) | 200~7000KW |
3 | Input Frequency(Hz) | 45~65Hz |
4 | Rated input voltage(kV) | 3/3.3kV/4.16kV/6/6.6kV/10/11kV (+15%~ -35%) |
5 | THDi at power grid | <3% (Permissible value≤4%) |
6 | THDu at output side | <3% (Permissible value≤5%) |
7 | Input power factor | >0.95%(>20% of rated load) |
8 | Efficiency | >97%(under a rated load) |
9 | Output frequency(Hz) | 0.5~120Hz |
10 | Output frequency resolution | 0.01Hz |
11 | Rated output current(A) | 36~600A |
12 | Overload capability | 120%(1min), 150%(3s), 200%(Immediate protection) |
13 | Control mode | V/F control or Vector control |
14 | Logical control I/O signal | 16 channels respectively |
15 | Analog input | 0~10V/4~20mA |
16 | Analog output | 0~10V/4~20mA Optional (2 channels) |
17 | Boolean input/output | Communications/Default point (expandable) |
18 | Acc & Dec time (S) | 0.1~3000s |
19 | Communication with host | CAN, Profibus, Modbus, RS232, RS485 etc |
20 | Cooling mode | Forced air cooling |
21 | Storage temperature | 00C~450C |
22 | Ambient temperature | -350C~+450C |
23 | Ambient humidity | 95%, no condensation |
24 | Protection grade | IP40 |
25 | Noise | <70DB |
- Q:Delta inverter reported CE4 reasons? Casually asked how many kinds of CE under a total
- If the Delta C2000_M is the Modbus drive can not handle Not to the official website under the manual
- Q:ASUS notebook power adapter can be universal? is it?
- ASUS notebook power adapter is not universal, depending on the model, the output voltage and current requirements are different, select the battery and consistent adapter. Note: different brands of laptop batteries may be different, so do not use, through the laptop battery voltage and current comparison power adapter voltage and current to judge. If the voltage and current are roughly the same can be used.
- Q:The relationship between the power supply of the notebook and the battery
- 2, when the laptop turns on the power adapter, and the battery power is low, the charging circuit detects the battery power is lower than the set value, the power adapter will side of the host power supply, while the battery charge. After the charge is restored, it is restored to the power supply state directly from the adapter. Therefore, the relationship between the power supply of the notebook and the battery is that the battery is charged by the power adapter when the battery level is below the set value.
- Q:Siemens g120 inverter torque limit what is the meaning
- Torque is a strain, the inverter can not actively control the output torque size, only according to the size of the load demand torque, the output of the corresponding torque.
- Q:Laptop warranty period is not over, the power adapter is broken, repair money?
- Look at your reinsurance period if not in the warranty period is not man-made damage can be changed or for the change
- Q:Three-phase asynchronous AC motor speed control method
- Third, cascade speed control method Cascade speed regulation refers to the winding motor in the rotor loop into the adjustable additional potential to change the motor slip, to speed control purposes. Most of the slip power is absorbed by the additional potential in series, and the additional device is used to return the absorbed slip power to the grid or to convert the energy. According to the slip power absorption and utilization, cascade speed can be divided into motor cascade speed, mechanical cascade speed control and thyristor cascade speed form, the use of thyristor cascade speed, which features: Can be transferred in the speed of the process of slip loss back to the grid or production machinery, the higher efficiency; Device capacity and speed range is proportional to the investment province, for the speed range of 70% -90% of the rated speed of production machinery; Speed ??control device failure can switch to full speed operation, to avoid shutdown; Thyristor cascade speed power factor is low, the greater the impact of harmonics. This method is suitable for use in wind turbines, water pumps and rolling mills, mine hoists, extruders.
- Q:Notebook power adapter on how to look at power
- It should be noted that there are many in Japan to buy a notebook or over there in the parallel imports, input only support 110V in China is not used, because the Chinese standard is 220V. Now the subject is 90W 20V. Output voltage and power will be identified, such as the target for the 90W 20V, that output power is 90W, the output voltage is 20V. If only the output voltage and output current are identified,
- Q:Is the laptop power adapter hot?
- Third, the power of the nominal voltage than my books the battery voltage is much higher, not an accident, right? First of all, to know is that the power supply to the books and the battery power supply to the notebook is different. Battery-powered, the battery output is pure DC, very clean, the battery voltage is neither possible nor need to design a high, lithium battery chemical properties determine a cell output voltage can only be about 3.6V, so Many batteries are used in three cascade way, 10.8V also became a very popular battery voltage. Some batteries are slightly larger than the integer value of 3.6V, such as 3.7V or 11.2V, etc., in fact, to protect the battery. Power supply, the situation is more complex, first of all need to add voltage to further regulation filter to ensure that the power performance is not very good in the case of stable work, the voltage regulator after the two parts of the city, all the way to the work of the power supply , The other way to the battery charge to the part of the power supply to the battery when the same power supply, and the part of the battery charge through the battery charge control circuit can be added to the battery, the control circuit can be very complex, so the power The voltage must be greater than the cell voltage to have sufficient capacity to supply the charge control circuit to the units. Finally the voltage actually added to the cell will never be the nominal voltage of your power supply. Rest assured.
- Q:Speed regulation method of three - phase asynchronous motor
- 1, frequency control, with the inverter, power 2, change the magnetic pole logarithm, not feasible. 3, stator series resistance, energy consumption
- Q:What is the common COM point of the PLC and the inverter? Is it positive?
- It depends on your PLC and inverter I / O is what type, the most simple can be divided into two kinds of NPN and PNP, NPN COM point is negative, PNP COM is positive.
1. Manufacturer Overview |
|
---|---|
Location | Beijing,China |
Year Established | 1998 |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | TIANJIN |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | ENGLISH,CHINESE |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
MV VFD AC Motor Drive 3KV 6KV 10KV
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1PC pc
- Supply Capability:
- 10,000pcs/year pc/month