Specifications of MV VFD AC Motor Drive 3KV 6KV 10KV

 

Direct medium voltage input and output 

 

IGBT power units in series to obtain MV by means of overlap wave 

 

Up to 40% saving rate

 

Application Fields of MV VFD AC Motor Drive 3KV 6KV 10KV

  • Power Generation: Induced draft fan, forced draft fan, condensate pump, feed pump, primary air fan, secondary air fan, booster fan, circulating pump, mill fan, slurry pump etc

  • Cement: draft fan, high-temperature fan, air blower, dust collection fan etc.

  • Metallurgy: blast furnace blower, slurry pump, feed water pump, dust fan, compressor etc.

  • Petroleum&Chemical: Water injection pump, crude oil pump, Compressor, fan, circulation pump, etc

  • Urban water supply: Water delivery pump, water intake pump, water supply pump, sewage treatment industry, self-fractionating pump etc

  • Minerals & Mining: Mud pump, ventilation fan, slurry pump etc

     

Others: Loads such as fan, pump and compressor in pharmaceutical, paper making and wind tunnel test.

Especially for: Fan and Pump

 

Power Plant

Pump, Fans

Steel Plant

Fans

Cement Plant

Fans

 

   

Product Structure of MV VFD AC Motor Drive 3KV 6KV 10KV

AC Motor Drive Variable Frequency Drive consists of By-pass cabinet, Transformer cabinet, power unit cabinet and controller cabinet from left to right.

 

 

AC Motor Drive MV Variable Frequency Drive

 

 

Technical advantages of MV VFD AC Motor Drive 3KV 6KV 10KV

  • No need of extra output filtering device

  • Directly driving the general medium voltage synchronous or asynchronous motor and the temperature of the motor will not be increased.

  • No need of motor derating operation

  • No dv/dt damage to insulation of motor and cable

  • No torque ripple induced by harmonics, and the service life of motors and mechanism devices can be extended

  • No cable length limited when voltage drop is in the allowable range.

Besides the above advantages, AC Motor Drive MV Variable Frequency Drive has the following functions and features:

  • Protection of overload, overheat, over-current, open-phase, grounding, over-voltage, negative sequence.

  • Current limited function

  • Interlock protection of control power supply

  • Two sets of control power hot standby for redundancy

  • Power cell by-pass function

  • Control cabinet automatic bypass function

  • Cabinet door opening alarm function

  • Lock-phase function

  • Synchronizing switch function between variable frequency and power frequency (optional)

  • Soft start of motors, no impact to mechanical equipment and network

  • Voltage source High-high variable frequency drive, it can realize No-step speed regulation, which makes the typical motors into intelligent motors.

  • High quality power input: By phase shifting of the secondary winding and multi-pulse diode rectifier, isolated powers can be acquired and supplied for power cells. (18 pulses for 3/3.3kV, 30/36 pulses for 6/6.6kV, 48/54 pulses for 10/11kV) By using the technique of multi-pulse rectifier, the harmonic current could be eliminated greatly.

  • Power cell communicate with controller through optic-fiber, completely electric isolated

  • Inner set PID regulator, can realize running in closed-loop

  • Multiple communication methods with host computer, isolated RS485 interface, standard MODBUS RTU, communication protocol, PROFIBUS DP (optional), industrial Ethernet communication protocol (optional)

  • Accurately fault records, can inquiry information and locate fault

  • Compact construction, reasonable layout (can do customer-design)

  • Very good protective design to dust, ferrum pulveratum, acid mist, moisture etc.

  • Bypass cabinethas a function of "five-protection", meanwhile, it has a pressure relief channel to ensure the safety of operators.

  • Modularized design of power units, interchangeable and easy to produce and repair.

Technical parameters of MV VFD AC Motor Drive

Series No

Parameters

Value

1

HVF Capacity(KVA)

250~8750kVA

2

Power of adaptive motor(KW)

200~7000KW

3

Input Frequency(Hz)

45~65Hz

4

Rated input voltage(kV)

3/3.3kV/4.16kV/6/6.6kV/10/11kV (+15%~ -35%)

5

THDi at power grid

<3% (Permissible value≤4%)

6

THDu at output side

<3% (Permissible value≤5%)

7

Input power factor

>0.95%(>20% of rated load)

8

Efficiency

>97%(under a rated load)

9

Output frequency(Hz)

0.5~120Hz

10

Output frequency resolution

0.01Hz

11

Rated output current(A)

36~600A

12

Overload capability

120%(1min), 150%(3s), 200%(Immediate protection)

13

Control mode

V/F control or Vector control

14

Logical control I/O signal

16 channels respectively

15

Analog input

0~10V/4~20mA

16

Analog output

0~10V/4~20mA Optional (2 channels)

17

Boolean input/output

Communications/Default point (expandable)

18

Acc & Dec time (S)

0.1~3000s

19

Communication with host

CAN, Profibus, Modbus, RS232, RS485 etc

20

Cooling mode

Forced air cooling

21

Storage temperature

00C~450C

22

Ambient temperature

-350C~+450C

23

Ambient humidity

95%, no condensation

24

Protection grade

IP40

25

Noise

<70DB

 

Q: A 4-pole AC motor into a 2-pole AC motor, the motor is controlled by the inverter, to make the maximum speed of the 2-pole motor and the original 4-pole
If it is normal V / F control, then do not need to modify too many parameters to limit the frequency limit of 50%
Q: What are the types of power adapter used in notebooks?
Notebook function is limited, such as power requirements of only 50-70 watts (W). In recent years, power requirements have risen above 100 W, but the expectations for weight and size have not improved accordingly. In addition, the need to meet the low standby power performance in the specification, external power (EPS) efficiency requirements and IEC1000-3-2 harmonic power requirements above 75 W make this challenge more difficult to deal with. This article explores new trends that enable power supply manufacturers to address these challenges and provide alternative solutions to choose from.
Q: Laptop power adapter is broken, which brand is better domestic
What brand of your laptop brand? It is best to be original,
Q: Can the laptop power adapter be generic?
Output voltage, current, interface can be used as well.
Q: What are the differences and links between the soft starters and the frequency converters, and their respective principles and uses?
The soft starter is activated by adjusting the voltage and current, and the frequency converter starts the motor by changing the frequency of the power supply. The soft starter can theoretically smooth and gradually start the motor to the maximum speed. No impact current (ordinary start-up current is 6-7 times the rated current) The inverter is best suited for tap water and fans, etc. The soft starter is not suitable for everything except for heavy load start.
Q: On the notebook power adapter output current and voltage issues
This look at your computer is what brand if it is DELL may not be charged, some other brands can be used with some can not, if you can use the charge can then only charge time will be longer than the original power supply, the computer no effect, The current is not bigger than the original big line for a long time on the battery and the motherboard is not good!
Q: My motor is a low frequency 8 pole motor, about 80W. I would like to choose a frequency converter
Poor match, the program is unreasonable Current 1.5A, choose a single-phase 220v power supply, 370-500w inverter it
Q: Laptop power adapter is used to do what
Power and charge the notebook. Equivalent to power, mobile phone charger.
Q: Three sets of batteries (540V) DC power supply U / f inverter.
This is the reason for the battery characteristics, your group of easy to burn the battery discharge characteristics of the curve should not be partial to engage, so easy to burn. Ultimately it is your group of battery quality is relatively poor!
Q: The emitter E of the inverter inverter module and the AC output U are not directly connected together
Pairs of modules are connected in a phase branch The phase output is derived from the neutral point between the modules
As the leader in the field of medium Voltage Variable Frequency Drive, we have been focusing on providing the integrated solutions of automatic control and energy-saving technology etc. for customers, and its skill levels and market impact of medium voltage VFD are in the world-leading positions. We have provided products and services across more than twenty countries in six continents around the world, taking up the first market share (China) in the past nine years.

1. Manufacturer Overview

Location Beijing,China
Year Established 1998
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port TIANJIN
Export Percentage
No.of Employees in Trade Department
Language Spoken: ENGLISH,CHINESE
b) Factory Information
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches