• The inverter with good quality and price System 1
  • The inverter with good quality and price System 2
The inverter with good quality and price

The inverter with good quality and price

Ref Price:
get latest price
Loading Port:
Shekou
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
1000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

The detailed content:

FST - 610 high-power series high-performance non-inductive vector frequency converter

(7.5 kw to 630 kw, 3 phase, 380 v)


Software features:

G/P and wide scope of application.

A variety of control mode: V/F control, non-inductive vector control and torque control.

High start torque: 180%, 0.5 Hz.

Multistage speed, simple PLC and PID control.

Programmable input/output terminals.

Instantaneous power lost, don't stop function.

Multiple frequency setting methods.

Speed tracking restart function.

Automatic output voltage adjustment function.

Frequency hopping control function.

Volatile inhibition function.

A variety of fault protection function.


Structure features:

Layout optimization of components, small volume, light weight, easy to transport, installation and maintenance.

Good heat dissipation design, low temperature, stable performance.





Q:How to choose a Siemens inverter for a 5.5KW three-phase motor (2 pole)?
Siemens frequency conversion dedicated input / output filter, reactor, you contact us but smell it, the quality is guaranteed. We look forward to cooperation.
Q:How to choose the right inverter?
Inverter selection science or not for the normal operation of the frequency conversion system is essential. Many beginners on the general inverter selection method is not enough understanding, or even know the method, not sure the choice of the inverter model is positive solution, the following for everyone to solve the mystery. Inverter selection first look at the AC motor. Because the frequency conversion system generally first determine the motor, then select the inverter. In principle, it is necessary to determine the inverter model based on the actual current at which the AC motor is operating for a long time, and not on the motor nameplate. Inverter selection next depends on the load type. Frequency conversion system driven load equipment can be divided into three types: constant torque load, constant power load, fan, pump load, different load type select the inverter model is different.
Q:Who knows how the inverter is calculated?
There is no pole in the inverter, the electrode can be polarized, the greater the number of poles of the motor the slower the speed, please refer to.
Q:Delta inverter reported CE4 reasons? Casually asked how many kinds of CE under a total
If the Delta C2000_M is the Modbus drive can not handle Not to the official website under the manual
Q:My motor is a low frequency 8 pole motor, about 80W. I would like to choose a frequency converter
Poor match, the program is unreasonable Current 1.5A, choose a single-phase 220v power supply, 370-500w inverter it
Q:What is the adapter?
Easy Alliance Electronics (China) Co., Ltd. (eNetwork) currently has a different series, different types of adapters, original authentic, and sold at competitive prices.
Q:Please recommend a high performance laptop power adapter?
See what model you notebook ah, according to your power adapter voltage, rated current to match.
Q:Will the 75KW4 pole motor can be used to increase the speed of the inverter?
Can not, only slow down, on our national grid, 50HZ is the largest. At least with the inverter can not be achieved.
Q:What is the base blockade in the drive?
Base blockade is to deal with ul or ce such a special application of security agencies means that when the parking limit action after the base blockade even if the program can not malfunction, relative to the emergency stop circuit more harsh they will directly disconnect the power
Q:Speed of 3000 r / min three-phase motor how to change its speed
Speed of 3000 r / min three-phase motor speed: Variable pole speed Change the motor stator winding wiring way to change the motor pole number, which can be level to change the synchronous speed, to achieve a variable speed motor speed. This type of speed motor currently has a series of products to choose from, such as single-winding multi-speed motor. Frequency Change the asynchronous motor stator terminal input power frequency, and make it continuously adjustable to change its synchronous speed, to achieve the motor speed control method known as frequency control. The most energy efficient is the frequency conversion motor, but the need to install the inverter in the power part of the cost is too high.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords