General  of MV VFD Inverter Frequency

MV VFD Inverter Frequency is designed to be highly reliable with high-performance, yet easy to use.It can satisfy users' need for changing the speed of fans or pumps,as well as improve the productivity.

The series are compatible with all types of three-phase medium voltage asynchronous motors.


Application Filed of MV VFD Inverter Frequency

MV VFD Inverter Frequency can usually be applied in these fields:

Power generation: induced draft fans, forced draft fans, condensate exhausting pump, boiler feed water pumps, primary fan, secondary fan, circulating pump, mill fan, slurry pump, mill .

Metals: dusting fans, slurry pump, feeding pump, furnace fans, compressor, mill

Cement:  fan, discharge fan, waste gas fan, dust collecting fan, dust removing fan, mill.

Oil & Gas: water injection pump, oil transfer pumps, air compressor.

Mining: Fans, media pump, circulating pump, gas pump, oil separating pump, compressor, lift, mill, conveyer, hoisting machine.

Water: water supply pump, circulating pump.


System Principle Of MV VFD Inverter Frequency

Inverter Frequency

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Can the inverter stop intermittently during operation? If so, how to connect and set up
One of these terminals is a common terminal, which leads from the common terminal and is connected to the corresponding terminal via the relay contact
Q:Three-phase two-pole motor can be used to reduce the frequency of the inverter
If you need to be very slow, you can match a four-level motor ah, even more slowly with a reducer
Q:Master Hello a machine requires 500 speed matching 6-pole motor frequency converter transferred to about 28HZ
If the machine needs the same speed, constant 500r / min This can be directly with the motor, remove the inverter, but also save costs, while the motor at 50Hz, the maximum power point of rated power. Output torque is the most stable point. The pulley diameter becomes smaller and the reduction ratio increases, and the torque required by the motor becomes smaller, which is advantageous for the motor. 960/500 = 1.92, that is to say the motor pulley compared to the original tune less 1.92 times
Q:Can different brands of laptop power adapters be generic?
Power adapter can not use, the key to see two factors. First, the interface must first be the same interface or can not use. Second, the output current, the output current must be strictly consistent, otherwise it would be very dangerous, the laptop overload of the current is very fragile. The final output voltage I personally think can have a difference of type 5V. Because the battery on the voltage requirements up and down can have 5V floating. I have also used a high 5V adapter, has been no problem, but this is just my personal view. Strictly the same as the best. Oh, for reference only! Since you can plug in the normal use, indicating that the interface is consistent, and the output voltage and current are the same. Then I can responsibly tell you, rest assured to use it, there will be no problem.
Q:The inverter flat rate transferred to 29, on the submersible pump to burn the coil ?!
1. submersible pumps are generally the problem, far away from the reflection voltage, the pump insulation breakdown, in particular, to better pump. 2. Distance away, the inverter and pump connection thicker. 3. Then on the output filter.
Q:Will the asynchronous motor pole change the number of speed control can also be combined with the frequency converter
As you said the asynchronous motor after a very logarithmic change can be achieved on the speed of the "coarse tune", and then use the inverter is equivalent to add a "fine tune" device, but it seems a bit expensive, but to To see what you are on the occasion of the worthless.
Q:Why G120 inverter to be equipped with 4-pole motor?
Not necessarily must be equipped with four-pole motor, 2 pole, 6 pole, 8 pole, 12 pole can be used. As long as there is no problem with attention to current matching. Because the amount of 4-pole motor is the largest, all the frequency converter, are based on 4-pole motor for the control model design.
Q:Yasukawa inverter reported bb code that is the reason why the base blockade?
Not a drive failure! Is an external signal problem.
Q:Inverter with 2.2KW 6 pole motor. 1 minute 8 times reversing often burn the motor, how to solve. For the 2 pole 4KW motor is the same.
3. Can try (the effect is not necessarily), for a large inverter and variable frequency motor, and the inverter installed braking unit, braking resistor.
Q:Can the laptop 1.3a power adapter be used on a 1.5a device?
Theoretically impossible, because the power is small, but if it is a short period of time is possible, a long time to die.
As the leader in the field of medium Voltage Variable Frequency Drive, we have been focusing on providing the integrated solutions of automatic control and energy-saving technology etc. for customers, and its skill levels and market impact of medium voltage VFD are in the world-leading positions. We have provided products and services across more than twenty countries in six continents around the world, taking up the first market share (China) in the past nine years.

1. Manufacturer Overview

Location Beijing,China
Year Established 1998
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port TIANJIN
Export Percentage
No.of Employees in Trade Department
Language Spoken: ENGLISH,CHINESE
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range