Single/Three Phase Vector Control Frequency Inverter

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1 pc pc
Supply Capability:
5000pcs per month pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Description of Single/Three Phase Vector Control Frequency Inverter

CMAX  frequency  inverter is a high-quality, multi-function, low-noise variable frequency drive which is designed, developed and manufactured according to international standards. It can meet different needs of industrial conditions.The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse.


Features of Single/Three Phase Vector Control Frequency Inverter  

1).Adopts 16 bit microprocessor, sine wave PWM control 

2).Automatic torque ascension and automatic sliding compensation function 

3).Output frequency 0.1-400 Hz 

4).8 period of speed setting and 7 period can be running the program 

5).Low noise, carrier frequency can from 1 kHz-15 kHz adjustment 

6).Two paragraphs Acceleration and deceleration time and two segments of the S Curve slow and deceleration 

7).Simulation frequency set acceptable 0-10 VDC, 4-20 mA 

8).The built-in serial communication interface RS-485(baud rate can reach 38400) 

9).Save energy running and automatic voltage stabilizing section function (AVR) 

10).Adjustable V/F curve Acceleration and automatic and deceleration function 

11).Simple vector control and built-in PID control, and the simple positioning function 

12).Sleep/wake up function and zero velocity keep function


Structure of Single/Three Phase Vector Control Frequency Inverter


AC Motor Drive



Application of Single/Three Phase Vector Control Frequency Inverter


★Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.


★Plastic: extruder, hauling machine, decorating machine, etc.


★Pharmacy: mixer, roaster, etc.


★Woodworking: engraving machine, sander, veneer peeling lathe, etc.


★Papermaking: single type papermaking machine, etc.


★Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.


★Printing: cloth-washing machine, dye vat, etc.


★Cement: feeder, air blower, rotary furnace, mixer, crusher, etc


★Fan and pump: kinds of fans, blowers and pumps


Vector Control Frequency Inverter


Performance of Single/Three Phase Vector Control Frequency Inverter


InputRated voltageT4 series: Three phase 380v, ±15%
Frequency S/T2 series: Three/single phase 220V, ±15%
50/60Hz  ±5%
OutputVoltageT4 series: Three phase 0-380V
FrequencyS/T2 series: Three phase 0~220v
Overload ability150% rated current for 30s; 180% rated current for 1s;
DissipationCooling type Forced Cooling
Temperature protection Heatsink temperature >85℃ trip protection against overheat
Fan controlHeatsink temperature> 50℃, fan forced operation, frequency inverter continue work
ControlControl modeOpen-loop vector control, V/F control
PerformanceStart torqueOpen-loop vector control: 0.5Hz 180%; 
VF control: 0.5Hz 150%
Speed rangeOpen-loop vector control:1:150; 
VF control:1:100
Speed control precisionOpen-loop vector control: ±0.2%; 
VF control:±0.5%
FunctionChannel of operation commandKeyboard control,terminal control,communication control
Start modeDirect start, DC injection braking before start, speed tracking before start
DC injection brakingStart DC injection braking, stop DC injection braking
Dynamic brakingBuilt-in braking unit
Frequency source choiceKeyboard digital frequency setting, analog AVI setting
PID control setting, telecommunications setting
Frequency resolutionKeypad setting:0.01Hz; Analog setting: 0.1%
Carrier frequency1Khz~12Khz,
Acc/Dec time0.1~6000.0s or 0.01~600.00s
SignalAnalog inputAVI:0~10V
Keyboard potentiometer input: 0~10V
Analog outputAFM:0~10V or 0~20mA, Select through JP1 jumper
Digital inputA total of 28 kinds of function could be selected from S0 ~S5.
Digital output1 channel open collector output(MO1-MCM)
1 channel relay output( TA-TC normally open, TB-TC normally closed;
Communication PortCommunication protocolBased on RS485 hardware, support standard MODBUS protocol. 
Display FunctionsFour digital tube displayCan monitor the operation state of frequency inverter flexibly and conveniently.
Installation                                HumidityLess than 90%RH
VibrationLess than0.6G
Elevation0~1000m, reduce the rated specification 10% when lift 1000m for each. 
Storage temperature-20~60℃          
StructureDefend degreeIP20


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:The laptop's power adapter is too hot to do
The original adapter heat should be no problem, the fan mouth is very hot, the weather may be more and more hot it!
Q:Does the inverter set the number of poles to match the number of poles of the motor?
Variable-frequency (VFD) is the application of frequency conversion technology and microelectronics technology, by changing the motor operating frequency mode to control the AC motor power control equipment. The inverter is mainly composed of rectifier (AC variable DC), filter, inverter (DC variable AC), brake unit, drive unit, detection unit micro-processing unit and so on.
Q:Three motors, if coupled with the governor speed, is it necessary to add the inverter?
  Third, the cascade speed: Cascade speed refers to the winding motor rotor loop in the adjustable resistance to change the motor slip, to speed the purpose of the past, the most widely used.
Q:What is the characteristic of the variable pole speed method?
Edit this paragraph speed method First, variable pole alignment speed method This kind of speed control method is to change the stator winding winding way to change the cage motor stator pole pairs to achieve speed control purposes, features are as follows: with hard mechanical properties, good stability; no slip loss, high efficiency; wiring Simple, easy to control, low price; stepless speed regulation, large level difference, can not get smooth speed control; can be used with voltage regulator, electromagnetic slip clutch with the use of high efficiency and smooth speed control characteristics. This method is suitable for production machinery that does not need stepless speed regulation, such as metal cutting machine tools, lifts, lifting equipment, fans, pumps and so on. Second, the frequency control method Frequency conversion is to change the frequency of the motor stator power supply, thereby changing the speed of its synchronous speed control method. Frequency converter system can be divided into AC - DC - AC inverter and AC - AC inverter two categories, most of the current domestic use - cross - frequency converter. Features: high efficiency, no additional loss during the speed control process; wide range of applications, can be used for cage type asynchronous motor; speed range, hard and high precision; technical complexity, high cost, maintenance and repair difficult. This method is suitable for applications requiring high precision and better speed performance. Frequency conversion speed is divided into the following basic frequency and frequency above the speed, the fundamental frequency is constant torque speed control mode, the frequency above the speed is constant power speed mode.
Q:22kw.2 pole fan can use Fuji inverter?
Fan with Fuji? Money more people silly ... no comment ..
Q:Quartet of the TA, TC terminals have positive and negative?
This can not be said to be positive and negative, should be called the public, TA, is the common.
Q:How do I select a drive? Which brand is better
 Ampang letter company can provide different types of inverter, the user can according to their actual process requirements and the use of occasions to choose different types of frequency converter. When selecting the inverter, note the following precautions:     1, according to the load characteristics of the inverter, such as the load for the constant torque load; fan, pump load should be selected AM300 inverter.     2, select the inverter should be the actual motor current value as the basis for selection of the inverter, the motor rated power can only be used as a reference. Also should take full account of the output of the inverter contains high harmonics, will cause the motor power factor and efficiency will be bad. Therefore, with the inverter to the motor power supply and power grid power supply compared to the motor current increased by 10% and the temperature increase of about 20%. Therefore, in the choice of motor and inverter, should take into account the situation, the appropriate margin to prevent the temperature rise is too high, affecting the motor life.     3, the inverter to long cable operation, this time should take measures to suppress the long cable to the ground coupling capacitor, to avoid the inverter output is not enough. So the inverter should be amplified or selected to install the output reactor at the output of the inverter.
Q:Inverter with 2.2KW 6 pole motor. 1 minute 8 times reversing often burn the motor, how to solve. For the 2 pole 4KW motor is the same.
3. Can try (the effect is not necessarily), for a large inverter and variable frequency motor, and the inverter installed braking unit, braking resistor.
Q:3.7KW inverter with 2.2KW 6-pole motor running to see the inverter shows the current is more than 4A, with the amount of clamp to 2.8A
Probably the error of the clamp meter. 4 more current is correct.
Q:Inverter alarm a043, how is it
When a signal failure occurs, use the DTI board, if necessary, change P215. With P806 (Follow the parameter description) during operation can be converted to no encoder operation A043 is: n-actjump exceeds the allowable change speed of the speed encoder signal (P215) In addition, for the synchronous motor (P095 = 12): The motor speed is 2% higher than the inverter release time point. The inverter in the ready state can not exit. Check processing: Check if the cable is disconnected Check the tachometer to shield the ground Not only on the motor side but also on the inverter side The encoder cable does not allow disconnection Use only recommended encoders The encoder cable is not allowed to be laid with the power cable
We are a Hi-Tech enterprise establishing the networks of development, production, logistics and service extending to all over the world from Shenzhen and Dalian. Integrating the advanced technology from Europe, America, Japan and Taiwan,.We supply customers automatic and driving products with multi-functions, such as frequency inverter, servo motor and drive, soft starter, AC Choke, EMI filter, brake Units, Brake resistor etc.

1. Manufacturer Overview

Location Liaoning,China
Year Established 2001
Annual Output Value US$5 Million - US$10 Million
Main Markets North America
South America
Eastern Europe
Southeast Asia
Mid East
Eastern Asia
Western Europe
Company Certifications ISO9001

2. Manufacturer Certificates

a) Certification Name  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port DALIAN
Export Percentage
No.of Employees in Trade Department
Language Spoken: ENGLISH,CHINESE
b)Factory Information  
Factory Size: 5,000-10,000 square meters
No. of Production Lines Above 10
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Low and/or Average