Specifications of AC Motor Drive Variable Frequency Drive

Direct medium voltage input and output 

IGBT power units in series to obtain MV by means of overlap wave 

Up to 40% saving rate

 

Application Fields of AC Motor Drive Variable Frequency Drive

  • Power Generation: Induced draft fan, forced draft fan, condensate pump, feed pump, primary air fan, secondary air fan, booster fan, circulating pump, mill fan, slurry pump etc

  • Cement: draft fan, high-temperature fan, air blower, dust collection fan etc.

  • Metallurgy: blast furnace blower, slurry pump, feed water pump, dust fan, compressor etc.

  • Petroleum&Chemical: Water injection pump, crude oil pump, Compressor, fan, circulation pump, etc

  • Urban water supply: Water delivery pump, water intake pump, water supply pump, sewage treatment industry, self-fractionating pump etc

  • Minerals & Mining: Mud pump, ventilation fan, slurry pump etc

  • Others: Loads such as fan, pump and compressor in pharmaceutical, paper making and wind tunnel test.

  • Especially for: Fan and Pump

     

Power Plant

Pump, Fans

Steel Plant

Fans

Cement Plant

Fans

 

   

Product Structure

AC Motor Drive Variable Frequency Drive Consists Of By-pass Cabinet, Transformer Cabinet, Power Unit Cabinet And Controller Cabinet From Left To Right.

 

 

"AC Motor Drive MV Variable Frequency Drive"

 

 

Technical advantages of AC Motor Drive MV Variable Frequency Drive

  • No need of extra output filtering device

  • Directly driving the general medium voltage synchronous or asynchronous motor and the temperature of the motor will not be increased.

  • No need of motor derating operation

  • No dv/dt damage to insulation of motor and cable

  • No torque ripple induced by harmonics, and the service life of motors and mechanism devices can be extended

  • No cable length limited when voltage drop is in the allowable range.

     

Besides the above advantages, AC Motor Drive MV Variable Frequency Drive has the following functions and features:

  • Protection of overload, overheat, over-current, open-phase, grounding, over-voltage, negative sequence.

  • Current limited function

  • Interlock protection of control power supply

  • Two sets of control power hot standby for redundancy

  • Power cell by-pass function

  • Control cabinet automatic bypass function

  • Cabinet door opening alarm function

  • Lock-phase function

  • Synchronizing switch function between variable frequency and power frequency (optional)

  • Soft start of motors, no impact to mechanical equipment and network

  • Voltage source High-high variable frequency drive, it can realize No-step speed regulation, which makes the typical motors into intelligent motors.

  • High quality power input: By phase shifting of the secondary winding and multi-pulse diode rectifier, isolated powers can be acquired and supplied for power cells. (18 pulses for 3/3.3kV, 30/36 pulses for 6/6.6kV, 48/54 pulses for 10/11kV) By using the technique of multi-pulse rectifier, the harmonic current could be eliminated greatly.

  • Power cell communicate with controller through optic-fiber, completely electric isolated

  • Inner set PID regulator, can realize running in closed-loop

  • Multiple communication methods with host computer, isolated RS485 interface, standard MODBUS RTU, communication protocol, PROFIBUS DP (optional), industrial Ethernet communication protocol (optional)

  • Accurately fault records, can inquiry information and locate fault

  • Compact construction, reasonable layout (can do customer-design)

  • Very good protective design to dust, ferrum pulveratum, acid mist, moisture etc.

  • Bypass cabinethas a function of "five-protection", meanwhile, it has a pressure relief channel to ensure the safety of operators.

  • Modularized design of power units, interchangeable and easy to produce and repair.

     

Technical parameters of AC Motor Drive Variable Frequency Drive

 

Series No

Parameters

Value

1

HVF Capacity(KVA)

250~8750kVA

2

Power of adaptive motor(KW)

200~7000KW

3

Input Frequency(Hz)

45~65Hz

4

Rated input voltage(kV)

3/3.3kV/4.16kV/6/6.6kV/10/11kV (+15%~ -35%)

5

THDi at power grid

<3% (Permissible value≤4%)

6

THDu at output side

<3% (Permissible value≤5%)

7

Input power factor

>0.95%(>20% of rated load)

8

Efficiency

>97%(under a rated load)

9

Output frequency(Hz)

0.5~120Hz

10

Output frequency resolution

0.01Hz

11

Rated output current(A)

36~600A

12

Overload capability

120%(1min), 150%(3s), 200%(Immediate protection)

13

Control mode

V/F control or Vector control

14

Logical control I/O signal

16 channels respectively

15

Analog input

0~10V/4~20mA

16

Analog output

0~10V/4~20mA Optional (2 channels)

17

Boolean input/output

Communications/Default point (expandable)

18

Acc & Dec time (S)

0.1~3000s

19

Communication with host

CAN, Profibus, Modbus, RS232, RS485 etc

20

Cooling mode

Forced air cooling

21

Storage temperature

00C~450C

22

Ambient temperature

-350C~+450C

23

Ambient humidity

95%, no condensation

24

Protection grade

IP40

25

Noise

<70DB

 

Q:Is the laptop power adapter long-haul?
As long as the power, regardless of your access to the computer, the adapter is working. In fact, not much harm, anyway, five years of notebook life, this thing as long as not deliberately to damage, will be very durable, worse than the important parts of the computer slow. As long as the big brand, nothing Even if you broke, this thing can value a few money? In fact, the proposal or pull it, on the ground stumbling ... ...
Q:55 瓩 4 pole motor with a frequency of one hour can save much electricity
it is used in the fan pump load can save about 14-22 kWh, used in the general category, on Multiply your number by 55.
Q:There is no inverter comes with simple PLC programming function
The PLC is programmed to handle digital and analog, the core of the entire control system. It can output the digital to the inverter, so that the inverter is reversing, you can output the analog to the inverter set speed, but also through the communication, direct control inverter
Q:On the notebook power adapter output current and voltage issues
This current is the maximum current value of the adapter output, Voltage matching, of course, can be charged. It is recommended to select an adapter with an output current value that is slightly larger than the original.
Q:Delta VFD-F frequency converter how to adjust the number of poles
P148 look, this is to correspond to the number of poles of the motor, not to adjust the number of poles of the motor
Q:Fuji inverter motor set the number of poles will not have any effect?
The number of motor poles set incorrectly, self-learning when the motor parameters are not correct, not the correct parameters of the motor. Inverter control speed is not accurate, and the motor will heat, can not work properly.
Q:Lenovo g450 laptop power adapter specifications is what?
Lenovo G450 power adapter Model: ADP-90RH B LENOVO P / N: 36001681 Input: 100-240V ~ 1.5A 50-60Hz Output: 19V $ 4.74
Q:What are the differences and links between the soft starters and the frequency converters, and their respective principles and uses?
The soft starter is activated by adjusting the voltage and current, and the frequency converter starts the motor by changing the frequency of the power supply. The soft starter can theoretically smooth and gradually start the motor to the maximum speed. No impact current (ordinary start-up current is 6-7 times the rated current) The inverter is best suited for tap water and fans, etc. The soft starter is not suitable for everything except for heavy load start.
Q:What is the common COM point of the PLC and the inverter? Is it positive?
Generally refers to the common, and most of the negative
Q:Three sets of batteries (540V) DC power supply U / f inverter.
It is estimated that the battery should be string - and - series connection method, and then rectifier part of the converter (which may also be caused by the switch) is actually a series of diodes in series, positive and negative after the reverse is actually the battery is Negative shorts, resulting in burning, as to burn only one of the group of a few cells, it should be string - and - string and that group, because the parallel to bear it double voltage.
We are a professional inverter manufacturer integrating R&D, production and sales. With an experienced R&D and production team and sophisticated production lines, our company has become a domestic first-class inverter manufacturer by virtue of advanced technology, excellent quality, scientific management and perfect service

1. Manufacturer Overview

Location Zibo, China
Year Established 2004
Annual Output Value Below US$1 Million
Main Markets Middle-East America; Mid East; Northern Europ; Africa; Southeast Asia
Company Certifications CE;ISO

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Qingdao
Export Percentage 1% - 10%
No.of Employees in Trade Department 500-999 People
Language Spoken: English; Chinese
b)Factory Information  
Factory Size: Above 50,000 square meters
No. of Production Lines Above 8
Contract Manufacturing
Product Price Range High; Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products