Medium Voltage Variable Frequency Drive
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1PC pc
- Supply Capability:
- 10,000 per year pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Medium Voltage Variable Frequency Drive
High Voltage 6KV Frequency Inverter is designed to be highly reliable with high-performance, yet easy to use.It can satisfy users' need for changing the speed of fans or pumps,as well as improve the productivity.
The series are compatible with all types of three-phase medium voltage asynchronous motors.
Application Filed of High Voltage 6KV Frequency Inverter
High Voltage 6KV Frequency Invertercan usually be applied in these fields:
Power generation: induced draft fans, forced draft fans, condensate exhausting pump, boiler feed water pumps, primary fan, secondary fan, circulating pump, mill fan, slurry pump, mill .
Metals: dusting fans, slurry pump, feeding pump, furnace fans, compressor, mill
Cement: fan, discharge fan, waste gas fan, dust collecting fan, dust removing fan, mill.
Oil & Gas: water injection pump, oil transfer pumps, air compressor.
Mining: Fans, media pump, circulating pump, gas pump, oil separating pump, compressor, lift, mill, conveyer, hoisting machine.
Water: water supply pump, circulating pump.
Technology Data of High Voltage 6KV Frequency Inverter
6KV series VFD
Model | A06/050
| A06/050~
A06/080
| A06/080~
A06/100
| A06/100~
A06/170
| A06/170~
A06/220
| A06/220~
A06/400
| A06/400~
A06/610
|
Capacity(kVA) | ≤500 | 500~800 | 800~1000 | 1000~1750 | 1750~2250 | 2250~4000 | 4000~6250 |
Rated output current (A) | ≤50 | 50~80 | 80~100 | 100~170 | 170~220 | 220~400 | 400~610 |
Motor power (kW) | ≤400 | 400~630 | 630~800 | 800~1400 | 1400~1800 | 1800~3250 | 3250~5000 |
Input frequency | 45Hz~55Hz | ||||||
Rated input voltage | 6000V±10% | ||||||
Power factor | 0.95(>20%load) | ||||||
Efficiency | 0.96with rated load | ||||||
Output frequency | 0.5Hz~120Hz | ||||||
Frequency resolution | 0.01Hz | ||||||
Overload capacity | 120% 1 min, 150% immediately | ||||||
Analogue input | 0~10V/4~20mA | ||||||
Analogue output | 0~10V/4~20mA | ||||||
Acceleration/deceleration time | 0.1~3000s | ||||||
Digital input/output | expanded according to requirement | ||||||
Ambience temperature | 0~40℃ | ||||||
Storage/transport temperature | -40~70℃ | ||||||
Cooling | air cooling | ||||||
Ambience humidity | <90%,without condensation | ||||||
Altitude | <1000m | ||||||
IP class | IP20 | ||||||
Size(mm)(W×H×D) | 3600×2480×1200 | 3900×2480×1200 | 4200×2480×1200
5100×2480×1200
| 5200×2580×1200 | 6600×2580×1300
8700×2780×1400
| ||
Weight (kg) | 3500~4000 | 4000~5000 | 5000~6000 | 6000~8000 | 8000~14000 |
10KV series VFD
Model | A10/080 | A10/080~
A10/150
| A10/150~
A10/210
| A10/210~
A10/400
|
Capacity(kVA) | ≤1250 | 1250~2500 | 2500~3500 | 3500~6250 |
Rated output current (A) | ≤80Rated output current (A) | 80~150 | 150~210 | 210~400 |
Motor power(kW) | ≤1000 | 1000~2000 | 2000~2800 | 2800~5000 |
Input frequency | 45Hz~55Hz | |||
Rated input voltage | 10000V±10% | |||
Power factor | 0.95(>20%load) | |||
Efficiency | 0.96with rated load | |||
Output frequency | 0.5Hz~120Hz | |||
Frequency resolution | 0.01Hz | |||
Overload capacity | 120% 1 min, 150% immediately | |||
Analogue input | 0~10V/4~20mA | |||
Analogue output | 0~10V/4~20mA | |||
Acceleration/deceleration time | 0.1~3000s | |||
Digital input/output | expanded according to requirement | |||
Ambience temperature | 0~40℃ | |||
Storage/transport temperature | -40~70℃ | |||
Cooling | air cooling | |||
Ambience humidity | <90%,without condensation | |||
Altitude | <1000m | |||
IP class | IP20 | |||
Size(mm)(W×H×D) | 4500×2480×1200 | 5700×2480×1200 | 6800×2580×1300 | 10600×2580×1300 |
Weight(kg) | 3500~6000 | 6000~8000 | 8000~15000 | 15000~19000 |
System Principle of High Voltage 6KV Frequency Inverter
- Q: The inverter control power is also the same, the pole is not the same as the motor 6 or 4 pole can be used?
- Can be used, but is being used in the motor replacement, you need to change the frequency conversion.
- Q: Pump frequency converter instantaneous restart and restart the problem
- How the frequency converter works: The frequency converter is a power control device that transforms the power frequency power supply into another frequency by the on-off function of the power semiconductor device. We are now using the inverter is mainly used to pay - straight - cross mode (VVVF frequency conversion or vector control frequency), the first frequency AC power through the rectifier into a DC power supply, and then convert the DC power supply frequency, voltage can be controlled AC power supply to the motor. The circuit of the inverter is usually composed of four parts: rectifier, intermediate DC link, inverter and control. Rectifier part of the three-phase bridge uncontrollable rectifier, inverter part of the IGBT three-phase bridge inverter, and the output for the PWM waveform, the middle of the DC link for the filter, DC energy storage and buffer reactive power.
- Q: Is the speed of the motor controlled?
- Slip motor is composed of ordinary squirrel cage asynchronous motor, electromagnetic slip clutch and electrical control device composed of three parts. Asynchronous motor, the stepper motor is used as the prime mover, and when it rotates, the armature of the clutch is rotated together. The electric control device is a device that provides the excitation current of the slip clutch excitation coil. Electromagnetic slip clutch, which includes armature, magnetic pole and excitation coil three parts.
- Q: Is the inverter output current proportional to the output torque?
- The output voltage of the inverter is proportional to the frequency, which is to keep the motor flux constant, T = KIφ so the motor output torque is proportional to the inverter current.
- Q: Inverter ACS355 If the speed is outside the allowable range, how to set the limit value
- Remember, 2001 this should be set to a negative number, set to a positive number of your speed will never be less than this value.
- Q: How to lift Yaskawa inverter base blockade?
- 2. If you can not solve the problem, be sure to seek the help of professionals. ? 3. If the base of the frequency converter blocks the input signal. While the base blockade, the inverter power tube is all closed, this one is mainly to protect the power tube. So the external input signal once resolved, the base block is automatically removed.
- Q: Inverter with 2.2KW 6 pole motor. 1 minute 8 times reversing often burn the motor, how to solve. For the 2 pole 4KW motor is the same.
- 3. Can try (the effect is not necessarily), for a large inverter and variable frequency motor, and the inverter installed braking unit, braking resistor.
- Q: What is the frequency of `30 points
- Frequency is to change the frequency ah, see what you are variable frequency equipment.
- Q: How to choose a Siemens inverter for a 5.5KW three-phase motor (2 pole)?
- Beijing easy to create a website with Siemens inverter selection manual! You can log on online! Or contact them directly, they will give you professional answers!
- Q: How to choose a power adapter
- With the seller to an output 20V ,, 0.5A IBM single hole power adapter
1. Manufacturer Overview
Location | Beijing,China |
Year Established | 1998 |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | TIANJIN |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | ENGLISH,CHINESE |
b) Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Medium Voltage Variable Frequency Drive
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1PC pc
- Supply Capability:
- 10,000 per year pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords