Technical specifications
Table 2.3: Technical Parameters of QD200 Series Frequency Inverters
ITEM | SPECIFICATIONS | |
Main Input | Rated voltage and frequency | Single-phase 200V class: 200V-240V,50Hz/60Hz |
3-phase 400V class: 380V-480V , 50Hz/60Hz | ||
Allowable value of change | Voltage: 380V-15% ~ 480V+10%; Frequency: ±15% | |
Main output | Output voltage | Maximum output voltage equals to input voltage |
Output frequency | 0.5 Hz to 400 Hz | |
Overload capacity | 150% of rated output current for 60s, 200% of rated output current for 2s | |
Control performance | Modulation mode | 3-phase PWM, 2-phase PWM |
Control mode | V/f control for constant torque, V/f control for quadratic load, vector control without PG (open loop control),Energy-saving | |
Setting method of run command | Outer terminal, keyboard panel or serial communication | |
Setting method of speed command | Analog setting, keyboard, serial communication, UP/DOWN speed setting from external terminal | |
Speed setting resolution | Keyboard: 0.1 Hz | |
Analog setting: 0.05/50Hz (10bit) | ||
Speed control precision | V/f control:±2% | |
vector control without PG (open loop control): ±0.2% | ||
Speed control range | V/f control 1:40 | |
vector control without PG (open loop control) 1:200 | ||
Acceleration and Deceleration Time | 0-3200.0s | |
switching frequency | 1.5 kHz ~ 12 kHz, according to junction temperature automatically reduce the switching frequency | |
Analog input | Number | 2 ways: AI1、AI2 |
Type | DC voltage or DC current | |
Maximum input range | AI1: 0 to 5VDC, 0 to 10VDC, 0/4 to 20mA DC receivable AI2: 0 to 10VDC or PTC probe input receivable | |
Analog output | Number | 1 way: AO1 |
Type | DC voltage or DC current | |
Maximum input range | Voltage output: 0 to 10V, Current output: 0/4 to 20mA | |
logic input | Number | 0.75kw-11kW:LI1,LI2,LI3,LI4,AI1,AI2 15kW-500kW:LI,LI2,LI3,LI4,LI5,LI6,LI7,LI8,AI1,AI2 note:2 virtual logic input, capable of configuring AI1 and AI2 into logic input port (positive logic or negative logic) |
Type | Source or Sink | |
Maximum input range | 0-24VDC |
ITEM | SPECIFICATIONS | |
logic output | Number | 0.75kW-11kW: pulse signal output (LO-CLO)、relay output 1(T1A、T1B、T1C) 15kW-500kW:pulse signal output(LO-CLO)、relay output 1、2(T1A-T1B-T1C、T2A-T2B-T2C) |
pulse signal output | ||
relay output | RA-RB-RC, including a NO contact and a NC contact Maximum switch capacity: T1A,T1B: 3A at 250VAC, or 4A at 30VDC T2A,T2B: 2A at 250VAC or 30VDC | |
Serial communication interface | RS485 interface supports Modbus protocol. | |
Display | 4-digit LED digital display | For display of frequency setting, output frequency, fault code and parameter setting etc. |
Environment | Standard | Development of VSC200 series frequency inverters follows strict international standards and relevant recommended IEC and EN standards for control devices, especially IEC/EN61800-5-1 and IEC/EN61800-3. |
Altitude | Derating unnecessary when altitude is 1000m or below (Derating necessary at altitude higher than 1000m) | |
Ambient environment | 0.75kW-11kW: Reliable operation at -10 ~ 50°C without derating. When top protective cover is taken off, the environment temperature can be as high as +50 °C. Above +50 °C, the current drops by 2.2% for each rise of 1 °C in temperature. 15kW-500kW: Reliable operation at -10 ~ 40°C without derating. Storage: -25 ~ 70°C | |
Humidity | No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3 | |
Impact strength | 15gn for continuous 11ms, In accordance with IEC/EN60068-2-27 | |
Maximum antipollution capacity | Class 2, in accordance with IEC/EN61800-5-1 | |
Structure | Protection level | Top: IP41 (without removing the protective top cover). Other parts: IP20 |
Cooling Method | Forced Air cooling | |
Installation method | Wall mounted |
- Q: Inverter alarm a043, how is it
- When a signal failure occurs, use the DTI board, if necessary, change P215. With P806 (Follow the parameter description) during operation can be converted to no encoder operation A043 is: n-actjump exceeds the allowable change speed of the speed encoder signal (P215) In addition, for the synchronous motor (P095 = 12): The motor speed is 2% higher than the inverter release time point. The inverter in the ready state can not exit. Check processing: Check if the cable is disconnected Check the tachometer to shield the ground Not only on the motor side but also on the inverter side The encoder cable does not allow disconnection Use only recommended encoders The encoder cable is not allowed to be laid with the power cable
- Q: What is the laptop power adapter? Is it the battery?
- Notebook power adapter, of course, is not referring to the laptop battery.
- Q: What are the differences and links between the soft starters and the frequency converters, and their respective principles and uses?
- The soft starter is activated by adjusting the voltage and current, and the frequency converter starts the motor by changing the frequency of the power supply. The soft starter can theoretically smooth and gradually start the motor to the maximum speed. No impact current (ordinary start-up current is 6-7 times the rated current) The inverter is best suited for tap water and fans, etc. The soft starter is not suitable for everything except for heavy load start.
- Q: 5.5 kW 4-pole motor with the fastest speed can exceed the rated speed?
- Can not be exceeded Although the inverter can run out of the motor rated speed as the motor will soon burn You want your running speed of 2m / s you have to run 5m / s so go eggs do not pull the
- Q: What is the single axis of the inverter and multi-axis applications
- Inverter is mainly used for AC motor (asynchronous motor or synchronous motor) speed adjustment, is recognized as the AC motor the best and most promising speed control program, in addition to excellent speed performance, the inverter is also significant Energy-saving effect, is the enterprise technological transformation and product upgrading of the ideal speed control device. Since the introduction of China since the 80s of last century, the frequency converter as energy-saving applications and speed of process control more and more important automation equipment, has been rapid development and wide application.
- Q: Will the asynchronous motor pole change the number of speed control can also be combined with the frequency converter
- but the use of the inverter is based on changes in the load by changing the frequency of power into the motor at any time speed control, you can achieve a smooth and accurate stepless speed control is Now widely used in a speed control method, especially for the load often change or often in the light load operation of the motor.
- Q: Do you want to pay attention to the number of poles of the motor when selecting the inverter?
- Such as Schneider: ATV21 for fans, ATV11 simple machine pump, ATV31 simple machine, ATV61 fan with pump, ATV71 high power machine, high torque performance
- Q: What is the difference between AC and DC frequency converters?
- Inverter air conditioner is relatively speaking in terms of ordinary air conditioning, ordinary air conditioning compression motor using AC induction motor, speed unchanged, 50HZ when the speed is about 2880r / min. The inverter air conditioner is the first 220V, 50HZ single-phase AC into three-phase inverter AC (25 ~ 118HZ, 56 ~ 160), the supply of compressors, through the frequency changes to adjust the compressor speed, so that continuous cooling capacity to adapt to air conditioning Load needs. L inverter air conditioner works: inverter air conditioner compressor by the variable frequency motor drag, the power inverter output frequency changes in the alternating current to the motor, so that the motor speed can be based on the needs of indoor cooling and continuous change, the final compressor cooling capacity To achieve continuous changes in the automatic control. In order to meet the continuous changes in the cooling capacity, the refrigeration system uses an electronic expansion valve, the pulse motor switch valve core, rapid control into the evaporator refrigerant flow. Power frequency changes from the inverter to achieve, as shown in Figure 1: 220V, 50HZ of the mains input, the frequency converter A / D AC / DC conversion, D / A inverter, the output frequency required by the three-phase alternating current, Room switching power supply principle is similar.
- Q: Taian inverter 3.7KW 380V with 4.0KW 2 pole motor 18000 to 300HZ can it?
- The existing Taian inverter 380V3.7KW can bring 4.0KW 2 pole motor, 18000 to 300HZ can also see how you load, It is best to check your wiring tightness and whether the load is stuck. It is recommended to use the N310-4005-S3 this model, such as with the E510-405-H3 better.
- Q: What is the output voltage of the laptop power adapter?
- Generally have 19V of the common friends, I was 19V