Technical specifications

Table 2.3: Technical Parameters of QD200 Series Frequency Inverters

ITEM

SPECIFICATIONS

Main

Input

Rated voltage and frequency

Single-phase 200V class:  200V-240V,50Hz/60Hz

3-phase 400V class:  380V-480V , 50Hz/60Hz

Allowable value of change

Voltage: 380V-15% ~ 480V+10%;  Frequency: ±15%

Main output

Output voltage

Maximum output voltage equals to input voltage

Output frequency

0.5 Hz to 400 Hz

Overload capacity

150% of rated output current for 60s, 200% of rated output current for 2s

Control performance

Modulation mode

3-phase PWM, 2-phase PWM

Control mode

V/f control for constant torque, V/f control for quadratic load, vector control without PG (open loop control),Energy-saving

Setting method of run command

Outer terminal, keyboard panel or serial communication

Setting method of speed command

Analog setting, keyboard, serial communication, UP/DOWN speed setting from external terminal

Speed setting resolution

Keyboard: 0.1 Hz

Analog setting: 0.05/50Hz (10bit)

Speed control precision

V/f control:±2%

vector control without PG (open loop control): ±0.2%

Speed control range

V/f control 1:40

vector control without PG (open loop control)  1:200

Acceleration and Deceleration

Time

0-3200.0s

switching frequency

1.5 kHz ~ 12 kHz, according to junction temperature automatically reduce the switching frequency

Analog input

Number

2 ways: AI1、AI2

Type

DC voltage or DC current

Maximum input range

AI1: 0 to 5VDC, 0 to 10VDC, 0/4 to 20mA DC receivable

AI2: 0 to 10VDC or PTC probe input receivable

Analog output

Number

1 way: AO1

Type

DC voltage or DC current

Maximum input range

Voltage output: 0 to 10V, Current output: 0/4 to 20mA

logic input

Number

0.75kw-11kW:LI1,LI2,LI3,LI4,AI1,AI2

15kW-500kW:LI,LI2,LI3,LI4,LI5,LI6,LI7,LI8,AI1,AI2

note:2 virtual logic input, capable of configuring AI1 and AI2 into logic input port (positive logic or negative logic)

Type

Source or Sink

Maximum input range

0-24VDC

ITEM

SPECIFICATIONS

logic output

Number

0.75kW-11kW: pulse signal output (LO-CLO)、relay output 1(T1A、T1B、T1C

15kW-500kW:pulse signal output(LO-CLO)、relay output 1、2(T1A-T1B-T1C、T2A-T2B-T2C

pulse signal output

OC,output frequencycurrentoutput、ect other function

relay output

RA-RB-RC, including a NO contact and a NC contact

Maximum switch capacity:

T1A,T1B: 3A at 250VAC, or 4A at 30VDC

T2A,T2B: 2A at 250VAC or 30VDC

Serial communication interface

RS485 interface supports Modbus protocol.

Display

4-digit LED digital display

For display of frequency setting, output frequency, fault code and parameter setting etc.

Environment

Standard

Development of VSC200 series frequency inverters follows strict international standards and relevant recommended IEC and EN standards for control devices, especially IEC/EN61800-5-1 and IEC/EN61800-3.

Altitude

Derating unnecessary when altitude is 1000m or below (Derating necessary at altitude higher than 1000m)

Ambient environment

0.75kW-11kW: Reliable operation at -10 ~ 50°C without derating. When top protective cover is taken off, the environment temperature can be as high as +50 °C. Above +50 °C, the current drops by 2.2% for each rise of 1 °C in temperature. 15kW-500kW: Reliable operation at -10 ~ 40°C without derating.

Storage: -25 ~ 70°C

Humidity

No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3

Impact strength

15gn for continuous 11ms, In accordance with IEC/EN60068-2-27

Maximum antipollution capacity

Class 2, in accordance with IEC/EN61800-5-1

Structure

Protection level

Top: IP41 (without removing the protective top cover). Other parts: IP20

Cooling Method

Forced Air cooling

Installation method

Wall mounted

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Motor a speed, the inverter will burn what is going on, the inverter is a large yuan
Note that the quality of the inverter is not ye, and now this situation is already very rare, it is recommended to replace the inverter brand, you can use Bosch Rexroth, the British Witten, Huichuan, Senlan, Haili Pu, Ou Rui, etc. Branded.
Q:How to disassemble the notebook power adapter
HP laptop power adapter for the whole design of small sealed, you can follow the following steps to dismantle: 1, laptop power adapter for the injection molding package or with a strong adhesive glue, without any screws, so generally only with violence Cracked. However, as long as the method properly, after the dismantling of the power adapter can be restored to the original, do not carefully observe almost no traces of open.
Q:Is the laptop power adapter long-haul?
Can, rarely say there is a power adapter without power and failure, my notebook 5 years, never pull the power adapter plug, never power, there is no problem. Of course, save electricity and care from the point of view, it is recommended to pull the best, because the adapter is still in the working state.
Q:Old printing machine transformation, 37KW6 polar frequency motor with brake, inverter 55KW, now found running,
May be mechanical part of the card, try idling motor.
Q:Why G120 inverter to be equipped with 4-pole motor?
Not necessarily must be equipped with four-pole motor, 2 pole, 6 pole, 8 pole, 12 pole can be used. As long as there is no problem with attention to current matching. Because the amount of 4-pole motor is the largest, all the frequency converter, are based on 4-pole motor for the control model design.
Q:What is the difference between the electronic governor and the frequency converter on the motor speed regulation?
Electronic governor is the use of control thyristor conduction angle to change the motor supply voltage, the motor characteristics of the curve down to change the speed of asynchronous motor. Its characteristics are as follows: the motor speed adjustment range is small, low speed when the motor load capacity is poor, the speed decreases, the motor torque decreases, not applicable with constant load, when the speed is low, prone to stall phenomenon; Applicable to fan load. Inverter speed is to change the frequency of the motor to achieve the AC asynchronous motor speed adjustment, speed adjustment balance, the motor load characteristics do not change with the speed change, suitable for load adjustment and constant torque adjustment. Excellent performance, but the cost is higher.
Q:How to choose a power adapter
With the seller to an output 20V ,, 0.5A IBM single hole power adapter
Q:Why the number of motor poles increased, the inverter capacity will increase
The relationship between the motor current and the power is The power is equal to the current and voltage of the product again good with the power factor. (Simplex)
Q:The inverter flat rate transferred to 29, on the submersible pump to burn the coil ?!
The following describes the selection of the inverter Note: The inverter selection is mainly driven by the load characteristics and the actual motor current to set, in addition, there are the following precautions. 1, the environment: for some high temperature (higher than 50 degrees), high altitude (more than 1000 meters) of the application, the inverter selection should be appropriate to leave a margin to ensure that the inverter and motor life. 2, distance: the location of the inverter installation and drive the distance between the motor more than 50 meters, the frequency changer selection should cooperate with the reactor to reduce the carrier frequency. 3, a drag: a drive drag more than one motor, if the middle of the cable is too long, universal inverter selection will enlarge the use of a file, and each machine should be installed behind the fuse.
Q:11kw 6-pole motor can be used to adjust the inverter to 1800RPM?
Frequency conversion frequency f to 90Hz can. 1800 = 60x90 / 3,3 that is 3 pole, is 6 pole. Regardless of load.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range