Technical specifications

Table 2.3: Technical Parameters of QD200 Series Frequency Inverters

ITEM

SPECIFICATIONS

Main

Input

Rated voltage and frequency

Single-phase 200V class:  200V-240V,50Hz/60Hz

3-phase 400V class:  380V-480V , 50Hz/60Hz

Allowable value of change

Voltage: 380V-15% ~ 480V+10%;  Frequency: ±15%

Main output

Output voltage

Maximum output voltage equals to input voltage

Output frequency

0.5 Hz to 400 Hz

Overload capacity

150% of rated output current for 60s, 200% of rated output current for 2s

Control performance

Modulation mode

3-phase PWM, 2-phase PWM

Control mode

V/f control for constant torque, V/f control for quadratic load, vector control without PG (open loop control),Energy-saving

Setting method of run command

Outer terminal, keyboard panel or serial communication

Setting method of speed command

Analog setting, keyboard, serial communication, UP/DOWN speed setting from external terminal

Speed setting resolution

Keyboard: 0.1 Hz

Analog setting: 0.05/50Hz (10bit)

Speed control precision

V/f control:±2%

vector control without PG (open loop control): ±0.2%

Speed control range

V/f control 1:40

vector control without PG (open loop control)  1:200

Acceleration and Deceleration

Time

0-3200.0s

switching frequency

1.5 kHz ~ 12 kHz, according to junction temperature automatically reduce the switching frequency

Analog input

Number

2 ways: AI1、AI2

Type

DC voltage or DC current

Maximum input range

AI1: 0 to 5VDC, 0 to 10VDC, 0/4 to 20mA DC receivable

AI2: 0 to 10VDC or PTC probe input receivable

Analog output

Number

1 way: AO1

Type

DC voltage or DC current

Maximum input range

Voltage output: 0 to 10V, Current output: 0/4 to 20mA

logic input

Number

0.75kw-11kW:LI1,LI2,LI3,LI4,AI1,AI2

15kW-500kW:LI,LI2,LI3,LI4,LI5,LI6,LI7,LI8,AI1,AI2

note:2 virtual logic input, capable of configuring AI1 and AI2 into logic input port (positive logic or negative logic)

Type

Source or Sink

Maximum input range

0-24VDC

ITEM

SPECIFICATIONS

logic output

Number

0.75kW-11kW: pulse signal output (LO-CLO)、relay output 1(T1A、T1B、T1C

15kW-500kW:pulse signal output(LO-CLO)、relay output 1、2(T1A-T1B-T1C、T2A-T2B-T2C

pulse signal output

OC,output frequencycurrentoutput、ect other function

relay output

RA-RB-RC, including a NO contact and a NC contact

Maximum switch capacity:

T1A,T1B: 3A at 250VAC, or 4A at 30VDC

T2A,T2B: 2A at 250VAC or 30VDC

Serial communication interface

RS485 interface supports Modbus protocol.

Display

4-digit LED digital display

For display of frequency setting, output frequency, fault code and parameter setting etc.

Environment

Standard

Development of VSC200 series frequency inverters follows strict international standards and relevant recommended IEC and EN standards for control devices, especially IEC/EN61800-5-1 and IEC/EN61800-3.

Altitude

Derating unnecessary when altitude is 1000m or below (Derating necessary at altitude higher than 1000m)

Ambient environment

0.75kW-11kW: Reliable operation at -10 ~ 50°C without derating. When top protective cover is taken off, the environment temperature can be as high as +50 °C. Above +50 °C, the current drops by 2.2% for each rise of 1 °C in temperature. 15kW-500kW: Reliable operation at -10 ~ 40°C without derating.

Storage: -25 ~ 70°C

Humidity

No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3

Impact strength

15gn for continuous 11ms, In accordance with IEC/EN60068-2-27

Maximum antipollution capacity

Class 2, in accordance with IEC/EN61800-5-1

Structure

Protection level

Top: IP41 (without removing the protective top cover). Other parts: IP20

Cooling Method

Forced Air cooling

Installation method

Wall mounted

Q: Laptop warranty period is not over, the power adapter is broken, repair money?
Have to admit that the emergence of Thinkpad x100e, will hit the Internet completely decent, this product is not the name of the Internet, but "ultra-portable notebook", which also shows the x100e relentless and the Internet is willing to belong to similar products. It can be said, x100e is turned out in 2010 turned out professional jet client!
Q: In the official website to buy ThinkPad notebook, to the power adapter?
Where the power adapter to buy the general will be supporting
Q: Inverter signal line analog 4-20mA connection positive and negative can be reversed?
Analog input signal is particularly vulnerable to external interference, so the general use of twisted shield as a signal line; and wiring as short as possible, generally not more than 20 meters; if some use conditions are vulnerable to external serious interference, the analog signal Side need to add a filter capacitor or ferrite core.
Q: Is the inverter output current proportional to the output torque?
When 50HZ or more, the voltage is not increased, the magnetic flux decreases. P = T * n / 9550, if the motor output torque does not change, the current will increase, the motor heat overload
Q: Speed regulation method of three - phase asynchronous motor
1, frequency control, with the inverter, power 2, change the magnetic pole logarithm, not feasible. 3, stator series resistance, energy consumption
Q: Inverter with 2.2KW 6 pole motor. 1 minute 8 times reversing often burn the motor, how to solve. For the 2 pole 4KW motor is the same.
7 seconds more than a change, too often. It is estimated that the inverter will not work. Suggest:
Q: Fuji inverter motor set the number of poles will not have any effect?
The number of motor poles corresponds to the speed of the motor, the number of poles is not set when the speed of the control error, in the high speed requirements of the transmission is not allowed.
Q: The inverter flat rate transferred to 29, on the submersible pump to burn the coil ?!
1. submersible pumps are generally the problem, far away from the reflection voltage, the pump insulation breakdown, in particular, to better pump. 2. Distance away, the inverter and pump connection thicker. 3. Then on the output filter.
Q: Computer frequency changer to do cd frequency changer how points positive and negative
This inverter is 380V of the bar, the capacitor series is to increase the pressure, and then parallel to increase the capacity of the capacity of the capacitor and the inverter is proportional to the power, the greater the capacity of the capacitor capacity requirements are greater.
Q: The laptop's power adapter can be used on a desktop computer
that is the adapter is only one output input desktop machine needs a lot of different The interface can not be used completely Well

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords