Constant Current LED Driver 350MA 10V-50V 20 Watt
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 10 Pieces pc
- Supply Capability:
- 10,000 PiecPieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specification:
a.350mA 20W LED driver, constant voltage.
b. Epoxy encapsulated, IP67. Suitable for outdoor lighting application.
c. Automated protection for over load and over temperature
d. Aluminum housing, good for heat dissipation
e. Cooling by free air convection.
f. Application: LED spotlight, LED downlight, LED panel light
Model | GLS-20-350 | |
Voltage | 170-250V AC/90-130V AC | |
Frequency | 47-63 Hz | |
AC Current | 0.28A max@220V | |
Efficiency | 75% | |
DC Output | Voltage | 10V-50V |
Current | 350mA | |
Rated Power | 20W | |
Protection | Over Load | 20% exceed in short time is allowed |
Short Circuit | Auto recovery | |
Over Voltaqge | ≤280V | |
Over Temperature | ≤80°C | |
Others | Store Temperature | - 40--80°C |
Wokring Temperature | - 25--55°C | |
Dimension/Weight | 160*30*20MM / 250g (Aluminium Housing) | |
Packing/Carton Size | 50PC/CTN 385×240×175mm | |
Input Cable | VDE H03VV-F 3G×0.75mm2 (330mm) | |
Output Cable | VDE H03VV-F 2×0.75mm2 (330mmx2) | |
Certificate | CE | Compliant to EN 60950-1:2006;
EN61000-6-3:2001; EN 55022:2006+A1:2007; EN61000-4-2/-3; EN61000-6-1:2001; EN55024:1998+A1:2000+A2:2003
|
RoHs | Free from lead, Cadmium, Mercury, Hexavalent
Chromium and/or PBB &PBDE
|
- Q: How many can you bring with 220V? How many can you bring with 380V? There are 3 terminals on the transformer. There are 220V, 380V, 0, three terminals. 220V is the 220V terminal and the 0 connection. How can the 380V be connected? Is it 380V and 0 or 380V and 220V?
- Because some transformers are connected to 380V and 0, they can be 1000VA capacity, but because of the same line diameter, the 220V terminals and 0 can not provide the capacity of 1000VA.
- Q: What type of low voltage transformer should be adopted for safety lighting power supply?
- Isolated transformer, once 380V or 220V, two voltage, 36V, 24V, 12V, several categories, do not allow the use of autotransformer.
- Q: Why is the two side of the lighting transformer grounded?
- Single-phase transformer two side lighting to the ground, on the one hand is the lighting products now contain many semiconductor devices such as diodes, transistors, integrated circuits, semiconductor devices vulnerable to electrostatic damage, two side grounding contributes to the surge pressure factors produced by residual electrostatic discharge stay in the main circuit, avoid electrostatic protection, product life. In the 21 aspect, there is distributed capacitance between the two side and the primary side of the power transformer, and the high frequency surge disturbance caused by the primary side current source will directly enter the two side to the main circuit through the distributed capacitor. These unnecessary high frequency interference may jump into the sensitive signal source, make the control system malfunction, and the two side grounding of the power transformer can eliminate most of the undesirable effects of the distributed capacitance.
- Q: The difference between lighting transformers and control transformers
- A control transformer is a low voltage appliance, usually used as a power supply or part of a lighting for the control of electrical equipment such as machine tools. There are usually two different voltage outputs,
- Q: Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
- Line lights, lighting transformers in general how many low voltage, can live operation, but to do safety measures. For example, do not short-circuit, damp environment, wear insulation shoes, wearing insulating gloves and so on.In fact, all the voltage levels, as long as safety measures can be done live operation.
- Q: How is the lighting power of the 380V transformer calculated?
- The transformer (Transformer) principle should change the AC voltage of the primary coil, the main component of the device level by using electromagnetic coil core (core) main functions: voltage transformation, current transformer, impedance converter, isolation, voltage regulator
- Q: Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
- The self winding transformer is connected by all its windings, and depends on the position of the sliding contacts to change the magnitude of the voltage. Therefore, there is not only a magnetic connection between the primary winding of the autotransformer (the power circuit) and the two winding (the power supply circuit), but also the direct connection of the circuit. It forms a circuit with the earth, so it can not be used as the power source of the safety voltage
- Q: Can the 500 volt lighting transformer be changed into an electric welder?
- The structure of the electric welding machine is different from that of the transformer, and the magnetic gap of the iron core can be adjusted so that the welding current can be changed. In addition, the output voltage of the welder is also soft
- Q: Power and lighting transformers, lighting quality will be affected much?
- The bulb adopts a luminous two stage tube combined lamp holder, and the calculation process is very complicated. The secondary voltage is different in different combinations. Because it is a direct current ignition, but also consider the efficiency of its rectifier, but the total power is unchanged.
- Q: What's the function of the lighting transformer?
- Applies to some requirements for safe voltage 24V - 36V lighting sites. Such as: basement, tunnel, dangerous goods warehouse and so on. Then there is the (mobile, temporary) safety lighting for the overhaul.
1. Manufacturer Overview
Location | Shenzhen, Guangdong, China (Mainland) |
Year Established | 2011 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | North America; South America; Eastern Europe; Southeast Asia; Mid East; Western Europe; Central America; Northern Europe; South Asia |
Company Certifications | ROHS Test Report; Waterproof Power Supply CE-LVD; Waterproof Power Supply CE-EMC; CE-LVD |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Yantian |
Export Percentage | 41% - 50% |
No.of Employees in Trade Department | 3-5 People |
Language Spoken: | English, Chinese, Spanish, Japanese, Portuguese, German, French, Russian, Korean, Italian |
b) Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Constant Current LED Driver 350MA 10V-50V 20 Watt
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 10 Pieces pc
- Supply Capability:
- 10,000 PiecPieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords