• Aluminum Light Reflector S4516K 4.5 Inch System 1
Aluminum Light Reflector S4516K 4.5 Inch

Aluminum Light Reflector S4516K 4.5 Inch

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
300 Pieces pc
Supply Capability:
10000 Pieces per Week pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

S4516K  Reflector

1.Dia: 112*H85mm

2.aluminum reflector.

3.Surface treatment: anodized and sandblasting stpipes

4.material:aluminum1060#/1070#/1090#

5.thickness:0.8-2.0mm

6.Reasonable price: 0.1--3 USDollors one piece. Welcome inquiry.

7.Pakaging: plastic bag/inner carton /cartoon packing, or according to product requirement.  

8.Delivery detail: within 15-45 days

9. Application arrange:all kinds of Aluminum reflectors for lighting products, reflex housing for electric heater pad, accessories for household electrical appliances

 

We can do production according to your drawing.

Any design, any size, and any finish can be managed

Q:Power and lighting transformers, lighting quality will be affected much?
The bulb adopts a luminous two stage tube combined lamp holder, and the calculation process is very complicated. The secondary voltage is different in different combinations. Because it is a direct current ignition, but also consider the efficiency of its rectifier, but the total power is unchanged.
Q:Which is more energy saving by using 24V500W transformer lighting and 220V500W lighting?
If the transformer is not calculated, the loss is the same. If the calculation is the latter, save electricity.
Q:Is the substation separate from the power and illumination transformer?
There is only bus in the substation, and the station is connected with the transformer from the bus. If there is no electricity even in the bus, then the substation should not be considered active.
Q:1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
To 30VA/ square meters, the transformer needs 30KVA, with two 120 square copper wire. Specific should be used to determine the total power of the lighting transformer.
Q:Why should lighting transformers be used in factories and mines?
In some factories and mines (such as power plants), in order to supply power reliability, the power system is grounded in a three-phase, ungrounded, or neutral manner. In this way, the transformer must be connected to a neutral grounding type with a special transformer to supply power to the lighting.
Q:How many can you bring with 220V? How many can you bring with 380V? There are 3 terminals on the transformer. There are 220V, 380V, 0, three terminals. 220V is the 220V terminal and the 0 connection. How can the 380V be connected? Is it 380V and 0 or 380V and 220V?
Now is the three standard power supply, fire, fire and a single, zero line is three 220V, the fire is 380V. 40W lights can be 25.
Q:Why is elevator lighting transformer installed?
1) a lamp shall be installed at the highest and lowest point 0.5m away from the hoistway, and a light shall be installed at intervals not exceeding 7m, and a control switch shall be installed in the engine room and the bottom pit respectively;2) the lighting power supply for car top and hoistway shall be 36V; when 220V is adopted, the residual current action protector shall be installed;3) there is no lighting device for a closed well road with sufficient lighting conditions around the hoistway.
Q:Lighting, lights, transformers, bulb brightness is too low, what's the matter?
If you share a power line, you must calculate the current and select the appropriate wire to ensure normal pressure drop and safe use.
Q:What transformer can be used in a safety voltage lighting transformer?
An isolated transformer is a transformer that is electrically isolated from an input winding and an output winding. The isolated transformer is used to avoid accidental touching of the charged body at the same time, and the isolation of the transformer is to isolate the current of the former side winding coil.
Q:Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
Pe=19.5KW, installed capacityKx=1 coefficient of demandPjs=KxPe=19.5KW, calculated loadCOS, phi, =0.85, power factorIjs=KxPe/3/220/cos phi (Ijs calculates current, voltage, 380V/220V, three-phase)=1*19.5*1000/3/220/0.85=34.76A
We strive to be creative and responsive to our customers' needs, which in turn help strengthen our competitive advantage in the global marketplace. We never stop pushing ourselves to be more professional and excellent.

1. Manufacturer Overview

Location Guangdong,China (Mainland)
Year Established 2004
Annual Output Value US$2.5 Million - US$5 Million
Main Markets North America; South America; Eastern Europe; Southeast Asia; Africa; Oceania; Mid East; Eastern Asia; Western Europe; Central America; Northern Europe; Southern Europe; South Asia; Domestic Market
Company Certifications TUV

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Zhongshan,Shenzhen
Export Percentage 81% - 90%
No.of Employees in Trade Department 3-5 People
Language Spoken: English, Chinese
b)Factory Information  
Factory Size: 1,000-3,000 square meters
No. of Production Lines 6
Contract Manufacturing OEM Service Offered Buyer Label Offered
Product Price Range High and/or Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords